This page is part of the HL7 FHIR Implementation Guide: minimal Common Oncology Data Elements (mCODE) Release 1 - US Realm | STU1 (v1.16.0: STU 2 Ballot 1) based on FHIR R4. The current version which supercedes this version is 2.0.0. For a full list of available versions, see the Directory of published versions
<ValueSet xmlns="http://hl7.org/fhir">
<id value="mcode-teleradiotherapy-technique-vs"/>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p>This value set includes codes based on the following rules:</p><ul><li>Include these codes as defined in <a href="http://www.snomed.org/"><code>http://snomed.info/sct</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href="http://browser.ihtsdotools.org/?perspective=full&conceptId1=441799006">441799006</a></td><td>Intensity modulated radiation therapy (procedure)</td></tr><tr><td><a href="http://browser.ihtsdotools.org/?perspective=full&conceptId1=168524008">168524008</a></td><td>Radiotherapy - intraoperative control (procedure)</td></tr><tr><td><a href="http://browser.ihtsdotools.org/?perspective=full&conceptId1=169317000">169317000</a></td><td>Neutron capture therapy (procedure)</td></tr></table></li><li>Include these codes as defined in <a href="https://terminology.hl7.org/1.0.0//CodeSystem-umls.html"><code>http://terminology.hl7.org/CodeSystem/umls</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td>C3489631</td><td>Volumetric Modulated Arc Therapy</td></tr><tr><td>C5236971</td><td>2D Conventional Radiotherapy</td></tr></table></li><li>Include these codes as defined in <a href="CodeSystem-radiotherapy-cs.html"><code>http://terminology.hl7.org/CodeSystem/radiotherapy</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href="CodeSystem-radiotherapy-cs.html#radiotherapy-cs-3D">3D</a></td><td>Three Dimensional</td><td>Dose calculated with projection onto 3D imaging (e.g., CT or MR) delivered with either static aperture (Collimator, SRS Cone, Static MLC, blocks, etc) or non-IMRT/VMAT dynamic apertures (e.g., field-in-field, dynamic arc) using either single gantry angles or arcs.</td></tr><tr><td><a href="CodeSystem-radiotherapy-cs.html#radiotherapy-cs-PPS">PPS</a></td><td>Particle Passive Scattering</td><td>In proton or carbon ion beam therapy, a technique where the beam is spread out to larger dimension using a scattering device such as lead foil.</td></tr><tr><td><a href="CodeSystem-radiotherapy-cs.html#radiotherapy-cs-PSS">PSS</a></td><td>Particle Spot Scanning</td><td>In proton or carbon ion beam therapy, a technique where accelerated particles are focused into a small beam and then moved (scanned) over target regions in the patient.</td></tr><tr><td><a href="CodeSystem-radiotherapy-cs.html#radiotherapy-cs-MIX">MIX</a></td><td>Mixed</td><td>Both photon and particle based beams are used to deliver the radiation therapy.</td></tr></table></li></ul></div>
</text>
<url
value="http://hl7.org/fhir/us/mcode/ValueSet/mcode-teleradiotherapy-technique-vs"/>
<version value="1.16.0"/>
<name value="TeleradiotherapyTechniqueVS"/>
<title value="Teleradiotherapy Technique Value Set"/>
<status value="active"/>
<date value="2021-04-15T12:44:45+00:00"/>
<publisher value="HL7 International Clinical Interoperability Council"/>
<contact>
<name value="HL7 International Clinical Interoperability Council"/>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/cic"/>
</telecom>
<telecom>
<system value="email"/>
<value value="ciclist@lists.HL7.org"/>
</telecom>
</contact>
<description
value="Codes describing the techniques of teleradiotherapy (external beam) procedures."/>
<jurisdiction>
<coding>
<system value="urn:iso:std:iso:3166"/>
<code value="US"/>
<display value="United States of America"/>
</coding>
</jurisdiction>
<copyright
value="This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement"/>
<compose>
<include>
<system value="http://snomed.info/sct"/>
<concept>
<code value="441799006"/>
<display value="Intensity modulated radiation therapy (procedure)"/>
</concept>
<concept>
<code value="168524008"/>
<display value="Radiotherapy - intraoperative control (procedure)"/>
</concept>
<concept>
<code value="169317000"/>
<display value="Neutron capture therapy (procedure)"/>
</concept>
</include>
<include>
<system value="http://terminology.hl7.org/CodeSystem/umls"/>
<concept>
<code value="C3489631"/>
<display value="Volumetric Modulated Arc Therapy"/>
</concept>
<concept>
<code value="C5236971"/>
<display value="2D Conventional Radiotherapy"/>
</concept>
</include>
<include>
<system value="http://terminology.hl7.org/CodeSystem/radiotherapy"/>
<concept>
<code value="3D"/>
</concept>
<concept>
<code value="PPS"/>
</concept>
<concept>
<code value="PSS"/>
</concept>
<concept>
<code value="MIX"/>
</concept>
</include>
</compose>
</ValueSet>