This page is part of the HL7 FHIR Implementation Guide: minimal Common Oncology Data Elements (mCODE) Release 1 - US Realm | STU1 (v1.16.0: STU 2 Ballot 1) based on FHIR R4. The current version which supercedes this version is 2.0.0. For a full list of available versions, see the Directory of published versions
Summary
Defining URL: | http://hl7.org/fhir/us/mcode/ValueSet/mcode-brachytherapy-modality-vs |
Version: | 1.16.0 |
Name: | BrachytherapyModalityVS |
Title: | Brachytherapy Modality Value Set |
Status: | Active as of 2021-04-15T12:44:45+00:00 |
Definition: | Codes describing the modalities of brachytherapy procedures. |
Publisher: | HL7 International Clinical Interoperability Council |
Copyright: | This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement |
Source Resource: | XML / JSON / Turtle |
References
The concepts in this value set are drawn in priority order first from SNOMED CT (SCT), second from UMLS Metathesaurus, and lastly, from the (radiotherapy code system]RadiotherapyCS defined in this Implementation Guide. Missing SNOMED CT codes have been submitted for approval.
The following table shows potential mappings. This table may not be exhaustive and additional valid mappings may exist.
SNOMED CT Term | UMLS Metathesaurus Term | Radiotherapy Code System |
---|---|---|
none [1] [2] | none [3] | LDR-TEMP |
none [1] [4] | none [3] | LDR-PERM |
none | C3897809 “Pulsed-Dose Rate Brachytherapy” | not needed |
394902000 “High dose brachytherapy (procedure)” | C0454270 “High dose brachytherapy” | not needed |
438629002 “High dose rate electronic brachytherapy (procedure)” | C2584639 “High dose rate electronic brachytherapy” | not needed |
440252007 “Administration of radiopharmaceutical (procedure)” | C2584813 “Administration of radiopharmaceutical” [5] | not needed |
Notes:
This value set includes codes based on the following rules:
http://terminology.hl7.org/CodeSystem/radiotherapy
Code | Display | Definition |
LDR-TEMP | Low Dose Rate Brachytherapy - Temporary Placement | Radiation treatment that irradiates a body volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). |
LDR-PERM | Low Dose Rate Brachytherapy - Permanent Placement | Radiation treatment that irradiates a body volume with permanently placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). |
http://terminology.hl7.org/CodeSystem/umls
Code | Display |
C3897809 | Pulsed-Dose Rate Brachytherapy |
http://snomed.info/sct
Code | Display |
394902000 | High dose brachytherapy (procedure) |
438629002 | High dose rate electronic brachytherapy (procedure) |
440252007 | Administration of radiopharmaceutical (procedure) |
No Expansion for this valueset (Unknown Code System)
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
Source | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |