HL7 FHIR Implementation Guide: Profiles for Transfusion and Vaccination Adverse Event Detection and Reporting
1.0.1 - STU 1 Technical Correction United States of America flag

This page is part of the Profiles for ICSR Transfusion and Vaccination Adverse Event Detection and Reporting (v1.0.1: STU 1 Update) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: Sample MessageHeader for Transfusion report for Connecathon - XML Representation

Raw xml | Download



<MessageHeader xmlns="http://hl7.org/fhir">
  <id value="beafb541-3eab-eb9e-1bf1-5fa477d56e77"/>
  <meta>
    <lastUpdated value="2021-01-05T14:14:39+06:00"/>
    <profile
             value="http://hl7.org/fhir/us/icsr-ae-reporting/StructureDefinition/icsr-messageheader"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: MessageHeader</b><a name="beafb541-3eab-eb9e-1bf1-5fa477d56e77"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource MessageHeader &quot;beafb541-3eab-eb9e-1bf1-5fa477d56e77&quot; Updated &quot;2021-01-05 14:14:39+0600&quot; </p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-icsr-messageheader.html">ICSR MessageHeader</a></p></div><p><b>Message Processing Category</b>: notification</p><p><b>event</b>: Patient Adverse Event (Details: http://terminology.hl7.org/CodeSystem/v3-ActCode code PAT_ADV_EVNT = 'patient adverse event', stated as 'Patient Adverse Event')</p><h3>Destinations</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Endpoint</b></td><td><b>Receiver</b></td></tr><tr><td style="display: none">*</td><td><a href="http://example.org/ZZFDA">http://example.org/ZZFDA</a></td><td><a href="Organization-FDA.html">Organization/FDA</a> &quot;FDA&quot;</td></tr></table><p><b>sender</b>: <a href="Organization-BESTPrototype.html">Organization/BESTPrototype</a> &quot;BEST-Prototype&quot;</p><h3>Sources</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Endpoint</b></td></tr><tr><td style="display: none">*</td><td><a href="http://example.org/BEST-Pilot">http://example.org/BEST-Pilot</a></td></tr></table><p><b>reason</b>: Indicates receipt of a public health report <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/us/medmorph/2021Jan/CodeSystem-us-ph-triggerdefinition-namedevents.html">US Public Health TriggerDefinition Named Events</a>#received-public-health-report)</span></p><p><b>focus</b>: <a href="Composition-TransfusionExample.html">Composition/TransfusionExample</a></p></div>
  </text>
  <extension
             url="http://hl7.org/fhir/us/medmorph/StructureDefinition/ext-messageProcessingCategory">
    <valueCode value="notification"/>
  </extension>
  <eventCoding>
    <system value="http://terminology.hl7.org/CodeSystem/v3-ActCode"/>
    <code value="PAT_ADV_EVNT"/>
    <display value="Patient Adverse Event"/>
  </eventCoding>
  <destination>
    <endpoint value="http://example.org/ZZFDA"/>
    <receiver>
      <reference value="Organization/FDA"/>
    </receiver>
  </destination>
  <sender>
    <reference value="Organization/BESTPrototype"/>
  </sender>
  <source>
    <endpoint value="http://example.org/BEST-Pilot"/>
  </source>
  <reason>
    <coding>
      <system
              value="http://hl7.org/fhir/us/medmorph/CodeSystem/us-ph-triggerdefinition-namedevents"/>
      <code value="received-public-health-report"/>
    </coding>
  </reason>
  <focus>
    <reference value="Composition/TransfusionExample"/>
  </focus>
</MessageHeader>