HL7 FHIR Implementation Guide: Profiles for Transfusion and Vaccination Adverse Event Detection and Reporting
1.0.1 - STU 1 Technical Correction United States of America flag

This page is part of the Profiles for ICSR Transfusion and Vaccination Adverse Event Detection and Reporting (v1.0.1: STU 1 Update) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: Transfusion Sample Event - XML Representation

Raw xml | Download



<AdverseEvent xmlns="http://hl7.org/fhir">
  <id value="TransfusionExampleEvent"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/us/icsr-ae-reporting/StructureDefinition/transfusion-adverseevent"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: AdverseEvent</b><a name="TransfusionExampleEvent"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource AdverseEvent &quot;TransfusionExampleEvent&quot; </p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-transfusion-adverseevent.html">Transfusion Adverse Event</a></p></div><p><b>AgeAtTimeOfOnset</b>: 1 a<span style="background: LightGoldenRodYellow"> (Details: UCUM code a = 'a')</span></p><p><b>actuality</b>: actual</p><p><b>event</b>: Allergic transfusion reaction <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (meddra.org#10066173)</span></p><p><b>subject</b>: <a href="Patient-BESTPatient.html">Patient/BESTPatient</a> &quot; CM&quot;</p><p><b>date</b>: 2000-01-01</p><p><b>seriousness</b>: Serious <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-adverse-event-seriousness.html">AdverseEventSeriousness</a>#serious)</span></p><blockquote><p><b>suspectEntity</b></p><p><b>instance</b>: <a href="Procedure-TransfusionExampleTransfusion.html">Procedure/TransfusionExampleTransfusion</a></p><h3>Causalities</h3><table class="grid"><tr><td style="display: none">-</td><td><b>ProductRelatedness</b></td></tr><tr><td style="display: none">*</td><td>Suspect</td></tr></table></blockquote><blockquote><p><b>suspectEntity</b></p><p><b>instance</b>: <a href="MedicationAdministration-TransfusionEpinephrine.html">MedicationAdministration/TransfusionEpinephrine</a></p><h3>Causalities</h3><table class="grid"><tr><td style="display: none">-</td><td><b>ProductRelatedness</b></td></tr><tr><td style="display: none">*</td><td>Concomitant</td></tr></table></blockquote><blockquote><p><b>suspectEntity</b></p><p><b>instance</b>: <a href="MedicationAdministration-TransfusionDiphenhydramine.html">MedicationAdministration/TransfusionDiphenhydramine</a></p><h3>Causalities</h3><table class="grid"><tr><td style="display: none">-</td><td><b>ProductRelatedness</b></td></tr><tr><td style="display: none">*</td><td>Concomitant</td></tr></table></blockquote></div>
  </text>
  <extension
             url="http://hl7.org/fhir/us/icsr-ae-reporting/StructureDefinition/icsr-ext-ageattimeofonset">
    <valueAge>
      <value value="1"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="a"/>
    </valueAge>
  </extension>
  <actuality value="actual"/>
  <event>
    <coding>
      <system value="http://meddra.org"/>
      <code value="10066173"/>
      <display value="Allergic transfusion reaction"/>
    </coding>
  </event>
  <subject>
    <reference value="Patient/BESTPatient"/>
  </subject>
  <date value="2000-01-01">
    <extension
               url="http://hl7.org/fhir/us/icsr-ae-reporting/StructureDefinition/icsr-ext-eventenddate">
      <valueDateTime value="2019-01-20"/>
    </extension>
    <extension
               url="http://hl7.org/fhir/us/icsr-ae-reporting/StructureDefinition/icsr-ext-eventduration">
      <valueDuration>
        <value value="19.05"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="a"/>
      </valueDuration>
    </extension>
  </date>
  <seriousness>
    <coding>
      <system
              value="http://terminology.hl7.org/CodeSystem/adverse-event-seriousness"/>
      <code value="serious"/>
    </coding>
  </seriousness>
  <suspectEntity>
    <instance>
      <reference value="Procedure/TransfusionExampleTransfusion"/>
    </instance>
    <causality>
      <productRelatedness value="Suspect"/>
    </causality>
  </suspectEntity>
  <suspectEntity>
    <instance>
      <reference value="MedicationAdministration/TransfusionEpinephrine"/>
    </instance>
    <causality>
      <productRelatedness value="Concomitant"/>
    </causality>
  </suspectEntity>
  <suspectEntity>
    <instance>
      <reference value="MedicationAdministration/TransfusionDiphenhydramine"/>
    </instance>
    <causality>
      <productRelatedness value="Concomitant"/>
    </causality>
  </suspectEntity>
</AdverseEvent>