Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry vs http://hl7.org/fhir/us/ecr/StructureDefinition/travel-history-observation

Left:US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry)
Right:Travel History Observation (http://hl7.org/fhir/us/ecr/StructureDefinition/travel-history-observation)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry' vs 'http://hl7.org/fhir/us/ecr/StructureDefinition/travel-history-observation'
ErrorStructureDefinition.versionValues for version differ: '3.1.1' vs '1.1.0'
InformationStructureDefinition.nameValues for name differ: 'USCorePulseOximetryProfile' vs 'Travel_History_Observation'
InformationStructureDefinition.titleValues for title differ: 'US Core Pulse Oximetry Profile' vs 'Travel History Observation'
InformationStructureDefinition.dateValues for date differ: '2020-06-29' vs '2020-12-16T19:27:50+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 US Realm Steering Committee' vs 'HL7 Public Health Work Group (http://www.hl7.org/Special/committees/pher/index.cfm)'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/oxygensat' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'FHIR Oxygen Saturation Profile' 'eICR Travel History'
WarningObservationElements differ in definition: 'This profile defines how to represent pulse oximetry and inspired oxygen concentration based on the FHIR Core Vitals Profile. INSPIRED OXYGEN CONCENTRATION observations in FHIR using a standard LOINC code and UCUM units of measure.' 'Measurements and simple assertions made about a patient, device or other subject.'
ErrorObservationElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.statusElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Oxygen Saturation by Pulse Oximetry' 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'Oxygen Saturation.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood -).' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' 'Knowing what kind of observation is being made is essential to understanding the observation.'
ErrorObservation.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in binding.description: 'This identifies the vital sign result type.' 'Codes identifying names of simple observations.'
ErrorObservation.code.codingElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.subjectElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' 'Date or period of time spent in the location'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
WarningObservation.value[x]Elements differ in short: 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' 'Related resource that belongs to the Observation group'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
ErrorObservation.hasMemberElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/us/ecr/StructureDefinition/us-ph-transportation-details], CanonicalType[http://hl7.org/fhir/us/ecr/StructureDefinition/us-ph-exposure-contact-information]])
WarningObservation.componentElements differ in short: 'Used when reporting systolic and diastolic blood pressure.' 'Component results'
WarningObservation.componentElements differ in definition: 'Used when reporting systolic and diastolic blood pressure.' 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
ErrorObservation.componentElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.component.codeElements differ in binding.description: 'This identifies the vital sign result type.' 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Value recorded with UCUM' 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Sign Value recorded with UCUM.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.component.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/oxygensathttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyright
      .date2020-06-292020-12-16T19:27:50+00:00
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for use in querying and retrieving inspired O2 by pulse oximetry observations.This Observation profile represents a patient's travel history.
      • Values Differ
      .experimentalfalse
        .fhirVersion4.0.1
          .jurisdiction
            ..jurisdiction[0]urn:iso:std:iso:3166#US
              .kindresource
                .nameUSCorePulseOximetryProfileTravel_History_Observation
                • Values Differ
                .publisherHL7 US Realm Steering CommitteeHL7 Public Health Work Group (http://www.hl7.org/Special/committees/pher/index.cfm)
                • Values Differ
                .purpose
                  .statusactive
                    .titleUS Core Pulse Oximetry ProfileTravel History Observation
                    • Values Differ
                    .typeObservation
                      .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetryhttp://hl7.org/fhir/us/ecr/StructureDefinition/travel-history-observation
                      • Values Differ
                      .version3.1.11.1.0
                      • Values Differ

                      Structure

                      NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                      .. Observation ISI
                      • Elements differ in short: "FHIR Oxygen Saturation Profile" "eICR Travel History"
                      • Elements differ in definition: "This profile defines how to represent pulse oximetry and inspired oxygen concentration based on the FHIR Core Vitals Profile. INSPIRED OXYGEN CONCENTRATION observations in FHIR using a standard LOINC code and UCUM units of measure." "Measurements and simple assertions made about a patient, device or other subject."
                      • Elements differ in definition for mustSupport: "false" "true"
                      ... id ΣΣ
                        ... meta ΣΣ
                          ... implicitRules ?!Σ?!Σ
                            ... language
                              ... text
                                ... contained
                                  ... extension ExtensionExtension
                                    ... modifierExtension ?!?!
                                      ... identifier ΣΣ
                                        ... basedOn ΣΣ
                                          ... partOf ΣΣ
                                            ... status ?!SΣ?!Σ
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... category S(Slice Definition)
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... code SΣΣ
                                            • Elements differ in short: "Oxygen Saturation by Pulse Oximetry" "Type of observation (code / type)"
                                            • Elements differ in definition: "Oxygen Saturation." "Describes what was observed. Sometimes this is called the observation "name"."
                                            • Elements differ in comments: "The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood -)." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                            • Elements differ in requirements: "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)." "Knowing what kind of observation is being made is essential to understanding the observation."
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            • Elements differ in binding.description: "This identifies the vital sign result type." "Codes identifying names of simple observations."
                                            .... id
                                              .... extension ExtensionExtension
                                                .... coding SΣ(Slice Definition)Σ
                                                • Elements differ in definition for mustSupport: "true" "false"
                                                .... text ΣΣ
                                                  ... subject SΣΣ
                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                  ... focus ΣΣ
                                                    ... encounter ΣΣ
                                                      ... effective[x] SΣISΣ
                                                      • Elements differ in short: "Often just a dateTime for Vital Signs" "Date or period of time spent in the location"
                                                      • Elements differ in definition: "Often just a dateTime for Vital Signs." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                                      ... issued ΣΣ
                                                        ... performer ΣΣ
                                                          ... value[x] SΣI(Slice Definition)ΣI
                                                          • Elements differ in short: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "Actual result"
                                                          • Elements differ in definition: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "The information determined as a result of making the observation, if the information has a simple value."
                                                          • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                          ... dataAbsentReason SII
                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                          ... interpretation
                                                            ... note
                                                              ... bodySite
                                                                ... method
                                                                  ... specimen
                                                                    ... device
                                                                      ... referenceRange II
                                                                        .... id
                                                                          .... extension ExtensionExtension
                                                                            .... modifierExtension ?!Σ?!Σ
                                                                              .... low II
                                                                                .... high II
                                                                                  .... type
                                                                                    .... appliesTo
                                                                                      .... age
                                                                                        .... text
                                                                                          ... hasMember ΣSΣ
                                                                                          • Elements differ in short: "Used when reporting vital signs panel components" "Related resource that belongs to the Observation group"
                                                                                          • Elements differ in definition: "Used when reporting vital signs panel components." "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group."
                                                                                          • Elements differ in definition for mustSupport: "false" "true"
                                                                                          • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/us/ecr/StructureDefinition/us-ph-transportation-details], CanonicalType[http://hl7.org/fhir/us/ecr/StructureDefinition/us-ph-exposure-contact-information]])
                                                                                          ... derivedFrom ΣΣ
                                                                                            ... component SΣI(Slice Definition)Σ(Slice Definition)
                                                                                            • Elements differ in short: "Used when reporting systolic and diastolic blood pressure." "Component results"
                                                                                            • Elements differ in definition: "Used when reporting systolic and diastolic blood pressure." "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations."
                                                                                            • Elements differ in definition for mustSupport: "true" "false"
                                                                                            .... id
                                                                                              .... extension ExtensionExtension
                                                                                                .... modifierExtension ?!Σ?!Σ
                                                                                                  .... code SΣΣ
                                                                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                                                                  • Elements differ in binding.description: "This identifies the vital sign result type." "Codes identifying names of simple observations."
                                                                                                  .... value[x] SΣIΣ
                                                                                                  • Elements differ in short: "Vital Sign Value recorded with UCUM" "Actual component result"
                                                                                                  • Elements differ in definition: "Vital Sign Value recorded with UCUM." "The information determined as a result of making the observation, if the information has a simple value."
                                                                                                  • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                                                                  .... dataAbsentReason SII
                                                                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                                                                  .... interpretation
                                                                                                    .... referenceRange

                                                                                                      doco Documentation for this format