Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab vs http://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings

Left:US Core Laboratory Result Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab)
Right:Dental Findings (http://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' vs 'http://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings'
ErrorStructureDefinition.versionValues for version differ: '4.0.0' vs '1.0.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreLaboratoryResultObservationProfile' vs 'DentalFindings'
InformationStructureDefinition.titleValues for title differ: 'US Core Laboratory Result Observation Profile' vs 'Dental Findings'
InformationStructureDefinition.dateValues for date differ: '2020-06-27' vs '2021-11-02T16:22:15+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'Payer/Provider Information Exchange Work Group'
WarningObservationElements differ in definition: 'This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements.' 'Measurements and simple assertions made about a patient, device or other subject.'
ErrorObservation.statusElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Laboratory Test Name' 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'The typical patterns for codes are: 1) a LOINC code either as a translation from a 'local' code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display.' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
ErrorObservation.encounterElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.effective[x]Elements differ in definition: 'For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
ErrorObservation.performerElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.value[x]Elements differ in short: 'Result Value' 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT] if the concept exists. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification.' 'The information determined as a result of making the observation, if the information has a simple value.'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.bodySiteElements differ in definition for mustSupport: 'false' 'true'
InformationObservation.bodySiteExample/preferred bindings differ at Observation.bodySite using binding from DentalFindings
ErrorObservation.componentElements differ in definition for mustSupport: 'false' 'true'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observation
      .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
      • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
      .date2020-06-272021-11-02T16:22:15+00:00
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for the minimal set of data to query and retrieve laboratory test resultsThis profile is used to convey point-in-time oral findings including findings of an odontogram, periodontal assessment, tooth-specific measurement, intraoral or extraoral soft tissue exam, TMJ, TMD, or occlusion assessment. Findings in this profile often support associated Dental Conditions/Problems. See the FHIR base resource descriptions for comparisons of [Condition](https://www.hl7.org/fhir/condition.html) and [Observation](https://www.hl7.org/fhir/observation.html). As multiple tooth surfaces, tooth numbers, and oral cavity areas may be applicable for a single observation, yet only a single Observation.bodySite is allowed, see SNOMED CT [Composition Grammar Syntax](http://hl7.org/fhir/snomedct.html#4.3.1.0.5) for correct use of post-coordinated concepts.
      • Values Differ
      .experimentalfalse
      • Removed the item 'false'
      .fhirVersion4.0.1
        .jurisdiction
          ..jurisdiction[0]urn:iso:std:iso:3166#US
            .kindresource
              .nameUSCoreLaboratoryResultObservationProfileDentalFindings
              • Values Differ
              .publisherHL7 International - US Realm Steering CommitteePayer/Provider Information Exchange Work Group
              • Values Differ
              .purpose
                .statusactive
                  .titleUS Core Laboratory Result Observation ProfileDental Findings
                  • Values Differ
                  .typeObservation
                    .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-labhttp://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings
                    • Values Differ
                    .version4.0.01.0.0
                    • Values Differ

                    Structure

                    NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                    .. Observation II
                    • Elements differ in definition: "This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements." "Measurements and simple assertions made about a patient, device or other subject."
                    ... id ΣΣ
                      ... meta ΣΣ
                        ... implicitRules ?!Σ?!Σ
                          ... language
                            ... text
                              ... contained
                                ... extension ExtensionExtension
                                  ... modifierExtension ?!?!
                                    ... identifier ΣΣ
                                      ... basedOn ΣΣ
                                        ... partOf ΣΣ
                                          ... status ?!SΣ?!Σ
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          ... Slices for category S
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          ... code SΣSΣ
                                          • Elements differ in short: "Laboratory Test Name" "Type of observation (code / type)"
                                          • Elements differ in definition: "The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC." "Describes what was observed. Sometimes this is called the observation "name"."
                                          • Elements differ in comments: "The typical patterns for codes are: 1) a LOINC code either as a translation from a "local" code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                          ... subject SΣSΣ
                                            ... focus ΣΣ
                                              ... encounter ΣSΣ
                                              • Elements differ in definition for mustSupport: "false" "true"
                                              ... effective[x] SΣISΣ
                                              • Elements differ in definition: "For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                              ... issued ΣΣ
                                                ... performer ΣSΣ
                                                • Elements differ in definition for mustSupport: "false" "true"
                                                ... value[x] SΣISΣI
                                                • Elements differ in short: "Result Value" "Actual result"
                                                • Elements differ in definition: "The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT] if the concept exists. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification." "The information determined as a result of making the observation, if the information has a simple value."
                                                ... dataAbsentReason SII
                                                • Elements differ in definition for mustSupport: "true" "false"
                                                ... interpretation
                                                  ... note
                                                    ... bodySite S
                                                    • Elements differ in definition for mustSupport: "false" "true"
                                                    • Example/preferred bindings differ at Observation.bodySite using binding from DentalFindings
                                                    ... method
                                                      ... specimen
                                                        ... device
                                                          ... referenceRange II
                                                            .... id
                                                              .... extension ExtensionExtension
                                                                .... modifierExtension ?!Σ?!Σ
                                                                  .... low II
                                                                    .... high II
                                                                      .... type
                                                                        .... appliesTo
                                                                          .... age
                                                                            .... text
                                                                              ... hasMember ΣΣ
                                                                                ... derivedFrom ΣΣ
                                                                                  ... component ΣSΣ
                                                                                  • Elements differ in definition for mustSupport: "false" "true"
                                                                                  .... id
                                                                                    .... extension ExtensionExtension
                                                                                      .... modifierExtension ?!Σ?!Σ
                                                                                        .... code ΣΣ
                                                                                          .... value[x] ΣΣ
                                                                                            .... dataAbsentReason II
                                                                                              .... interpretation
                                                                                                .... referenceRange

                                                                                                  doco Documentation for this format