Validation Results for PatientCostTransparency

Generated Thu Mar 30 13:40:53 UTC 2023, FHIR version 4.0.1 for hl7.fhir.us.davinci-pct#1.0.0 (canonical = http://hl7.org/fhir/us/davinci-pct (history)). See Full QA Report

Quality Checks
Publisher Version:IG Publisher Version: v1.3.4
Publication Code:davinci-pct . PackageId = hl7.fhir.us.davinci-pct, Canonical = http://hl7.org/fhir/us/davinci-pct
Realm Check for US:

Snomed: The IG doesn't use SNOMED CT

1 Profiles not based on US Core

Publication Request:
package-idhl7.fhir.us.davinci-pct
version1.0.0
pathhttp://hl7.org/fhir/us/davinci-pct/STU1
modemilestone
statustrial-use
sequenceSTU 1
descDa Vinci Patient Cost Transparency Implementation Guide Release 1 - US Realm STU
No Messages found - all good
Supressed Messages:24 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. hl7.fhir.us.davinci-pct1.0.0R4http://hl7.org/fhir/us/davinci-pct
... hl7.terminology.r45.0.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.0.0Latest Release is 5.1.0
... hl7.fhir.us.core3.1.1 OR4http://hl7.org/fhir/us/corehttp://hl7.org/fhir/us/core/STU3.1.1Latest Release is 5.0.1
... hl7.fhir.us.davinci-hrex1.0.0 MR4http://hl7.org/fhir/us/davinci-hrexhttp://hl7.org/fhir/us/davinci-hrex/STU1
.... hl7.fhir.us.core3.1.1 OR4http://hl7.org/fhir/us/corehttp://hl7.org/fhir/us/core/STU3.1.1see above. Latest Release is 5.0.1
.... hl7.fhir.us.udap-security0.1.0 OR4http://hl7.org/fhir/us/udap-securityhttp://hl7.org/fhir/us/udap-security/2021SepLatest Release is 1.0.0
..... hl7.fhir.us.core3.1.1 OR4http://hl7.org/fhir/us/corehttp://hl7.org/fhir/us/core/STU3.1.1see above. Latest Release is 5.0.1
Templates: hl7.davinci.template#current -> hl7.fhir.template#current -> hl7.base.template#current -> fhir.base.template#current
Dependent IGs:no references
Global Profiles:(none declared)
HTA Analysis:All OK
R5 Dependencies:(none)
Modifier Extensions:(none)
Previous Version Comparison: Comparison with version 0.1.0
IPA Comparison: n/a
Summary: errors = 3, warn = 0, info = 0, broken links = 0
FilenameErrorsWarningsHints
Build Errors000
C:\temp\hl7.fhir.us.davinci-pct#1.0.0\fsh-generated\resources\Bundle-PCT-AEOB-Bundle-1100
C:\temp\hl7.fhir.us.davinci-pct#1.0.0\fsh-generated\resources\Bundle-PCT-GFE-Bundle-Inst-1100
C:\temp\hl7.fhir.us.davinci-pct#1.0.0\fsh-generated\resources\Bundle-PCT-GFE-Bundle-Prof-1100

n/a Show Validation Information


C:\temp\hl7.fhir.us.davinci-pct#1.0.0\fsh-generated\resources\Bundle-PCT-AEOB-Bundle-1.json Show Validation Information (13)

PathSeverityMessage
Bundle.entry[0].resource/*ExplanationOfBenefit/PCT-AEOB-1*/.priority (l212/c10)errorFound a reference to a CodeSystem (http://terminology.hl7.org/CodeSystem/processpriority) where a ValueSet belongs

C:\temp\hl7.fhir.us.davinci-pct#1.0.0\fsh-generated\resources\Bundle-PCT-GFE-Bundle-Inst-1.json Show Validation Information (15)

PathSeverityMessage
Bundle.entry[0].resource/*Claim/PCT-GFE-Institutional-1*/ (l19/c8)error2 profiles found for entry resource. More than one is not supported at this time. (Type Claim: http://hl7.org/fhir/us/davinci-pct/StructureDefinition/davinci-pct-gfe-professional, http://hl7.org/fhir/us/davinci-pct/StructureDefinition/davinci-pct-gfe-institutional)

C:\temp\hl7.fhir.us.davinci-pct#1.0.0\fsh-generated\resources\Bundle-PCT-GFE-Bundle-Prof-1.json Show Validation Information (15)

PathSeverityMessage
Bundle.entry[0].resource/*Claim/PCT-GFE-Professional-MRI*/ (l19/c8)error2 profiles found for entry resource. More than one is not supported at this time. (Type Claim: http://hl7.org/fhir/us/davinci-pct/StructureDefinition/davinci-pct-gfe-professional, http://hl7.org/fhir/us/davinci-pct/StructureDefinition/davinci-pct-gfe-institutional)

Suppressed Messages (Warnings, hints, broken links)

Examples codes that can't be validated as they are part of proprietary code systems that require special license.

The GFE Patient examples include a patient identifier that is not a member number as defined by the only slice hrex-patient-demographics

Warning about using US Core Coverage, which is not available in US Core 3.1.1 which we are using. The variance was approved by cross workgroup projects on 2/9/2023: https://jira.hl7.org/browse/FHIR-40344

Warning: Code Systems and Value Sets that are referenced in the guide but are not expanded and validatable because they are part of proprietary code systems that require special license.

Errors sorted by type


BUNDLE_BUNDLE_ENTRY_MULTIPLE_PROFILES

C:\temp\hl7.fhir.us.davinci-pct#1.0.0\fsh-generated\resources\Bundle-PCT-GFE-Bundle-Inst-1.json2 profiles found for entry resource. More than one is not supported at this time. (Type Claim: http://hl7.org/fhir/us/davinci-pct/StructureDefinition/davinci-pct-gfe-professional, http://hl7.org/fhir/us/davinci-pct/StructureDefinition/davinci-pct-gfe-institutional)
C:\temp\hl7.fhir.us.davinci-pct#1.0.0\fsh-generated\resources\Bundle-PCT-GFE-Bundle-Prof-1.json2 profiles found for entry resource. More than one is not supported at this time. (Type Claim: http://hl7.org/fhir/us/davinci-pct/StructureDefinition/davinci-pct-gfe-professional, http://hl7.org/fhir/us/davinci-pct/StructureDefinition/davinci-pct-gfe-institutional)

Terminology_TX_ValueSet_NotFound_CS

C:\temp\hl7.fhir.us.davinci-pct#1.0.0\fsh-generated\resources\Bundle-PCT-AEOB-Bundle-1.jsonFound a reference to a CodeSystem (http://terminology.hl7.org/CodeSystem/processpriority) where a ValueSet belongs