Data Exchange For Quality Measures Implementation Guide
5.0.0 - STU5 United States of America flag

This page is part of the Da Vinci Data Exchange for Quality Measures (DEQM) FHIR IG (v5.0.0: STU5 (v5.0.0)) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

OperationDefinition: Submit Data

Official URL: http://hl7.org/fhir/us/davinci-deqm/OperationDefinition/submit-data Version: 5.0.0
Standards status: Trial-use Maturity Level: 0 Computable Name: SubmitData
Other Identifiers: OID:2.16.840.1.113883.4.642.40.23.33.7

The submit-data operation is used to submit MeasureReports and any data of interest for one or more measures for one or more subjects. Each submitted Bundle SHOULD contain resources for a single subject and SHOULD contain all of the MeasureReport and data of interest related to that subject.

Generated Narrative: OperationDefinition submit-data

URL: [base]/Measure/$deqm-submit-data

Parameters

UseNameScopeCardinalityTypeBindingDocumentation
INbundle1..*Bundle