This page is part of the Quality Measure STU2 for FHIR R4 Implementation Guide (v2.0.0: STU 2) based on FHIR R4. The current version which supercedes this version is 3.0.0. For a full list of available versions, see the Directory of published versions
D.4.1.4 StructureDefinition: device-softwaresystem-cqfm - Mappings
Mappings for the StructureDefinition-device-softwaresystem-cqfm Profile.
CQFMDevice |
Device | Entity. Role, or Act, Device |
text | Act.text? |
contained | N/A |
extension | N/A |
modifierExtension | N/A |
identifier | .id |
udiCarrier | .id and .code |
id | n/a |
extension | n/a |
modifierExtension | N/A |
deviceIdentifier | Role.id.extension |
issuer | Role.id.root |
jurisdiction | Role.scoper |
carrierAIDC | Role.id.extension |
carrierHRF | Role.id.extension |
entryType | NA |
status | .statusCode |
distinctIdentifier | .lotNumberText |
manufacturer | .playedRole[typeCode=MANU].scoper.name |
manufactureDate | .existenceTime.low |
expirationDate | .expirationTime |
lotNumber | .lotNumberText |
serialNumber | .playedRole[typeCode=MANU].id |
deviceName | |
id | n/a |
extension | n/a |
modifierExtension | N/A |
type | .playedRole[typeCode=MANU].code |
modelNumber | .softwareName (included as part) |
partNumber | .playedRole[typeCode=MANU].id |
specialization | |
id | n/a |
extension | n/a |
modifierExtension | N/A |
version | |
id | n/a |
extension | n/a |
modifierExtension | N/A |
property | |
id | n/a |
extension | n/a |
modifierExtension | N/A |
patient | .playedRole[typeCode=USED].scoper.playedRole[typeCode=PAT] |
owner | .playedRole[typeCode=OWN].scoper |
contact | .scopedRole[typeCode=CON].player |
location | .playedRole[typeCode=LOCE].scoper |
url | .telecom |
note | .text |
safety | NA |
Mappings for FiveWs Pattern Mapping (http://hl7.org/fhir/fivews)
CQFMDevice |
Device | |
identifier | FiveWs.identifier |
udiCarrier | FiveWs.identifier |
deviceIdentifier | FiveWs.what[x] |
status | FiveWs.status |
statusReason | FiveWs.status |
distinctIdentifier | FiveWs.what[x] |
manufacturer | FiveWs.what[x] |
manufactureDate | FiveWs.what[x] |
expirationDate | FiveWs.what[x] |
lotNumber | FiveWs.what[x] |
serialNumber | FiveWs.what[x] |
deviceName | |
type | FiveWs.what[x] |
modelNumber | FiveWs.what[x] |
partNumber | FiveWs.what[x] |
specialization | |
version | FiveWs.what[x] |
version | |
patient | FiveWs.subject[x], FiveWs.subject |
owner | FiveWs.source |
contact | FiveWs.source |
location | FiveWs.where[x] |
url | FiveWs.where[x] |
Mappings for UDI Mapping (http://fda.gov/UDI)
CQFMDevice |
Device | |
identifier | The serial number which is a component of the production identifier (PI), a conditional, variable portion of a UDI. The identifier.type code should be set to “SNO”(Serial Number) and the system left empty. |
udiCarrier | |
deviceIdentifier | The device identifier (DI), a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device. |
issuer | All UDIs are to be issued under a system operated by an Jurisdiction-accredited issuing agency.
GS1 DIs:
http://hl7.org/fhir/NamingSystem/gs1
HIBCC DIs:
http://hl7.org/fhir/NamingSystem/hibcc
ICCBBA DIs for blood containers:
http://hl7.org/fhir/NamingSystem/iccbba-blood
ICCBA DIs for other devices:
http://hl7.org/fhir/NamingSystem/iccbba-other |
carrierAIDC | A unique device identifier (UDI) on a device label a form that uses automatic identification and data capture (AIDC) technology. |
carrierHRF | A unique device identifier (UDI) on a device label in plain text |
distinctIdentifier | The lot or batch number within which a device was manufactured - which is a component of the production identifier (PI), a conditional, variable portion of a UDI. |
manufacturer | N/A |
manufactureDate | The date a specific device was manufactured - which is a component of the production identifier (PI), a conditional, variable portion of a UDI. For FHIR, The datetime syntax must converted to YYYY-MM-DD[THH:MM:SS]. If hour is present, the minutes and seconds should both be set to “00”. |
expirationDate | the expiration date of a specific device - which is a component of the production identifier (PI), a conditional, variable portion of a UDI. For FHIR, The datetime syntax must converted to YYYY-MM-DD[THH:MM:SS]. If hour is present, the minutes and seconds should both be set to “00”. |
lotNumber | The lot or batch number within which a device was manufactured - which is a component of the production identifier (PI), a conditional, variable portion of a UDI. |