US Core Implementation Guide
7.0.0 - STU7 United States of America flag

This page is part of the US Core (v7.0.0: STU7) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Resource Profile: USCoreBloodPressureProfile - Detailed Descriptions

Page standards status: Trial-use Maturity Level: 3

Definitions for the us-core-blood-pressure resource profile.

Guidance on how to interpret the contents of this table can be found here

0. Observation
ShortUS Core Blood Pressure Profile
2. Observation.code
ShortBlood Pressure
TypeCodeableConcept
Must Supporttrue
Pattern Value{
  "coding" : [{
    "system" : "http://loinc.org",
    "code" : "85354-9"
  }]
}
4. Observation.component
ShortComponent observations
Control2..*
Must Supporttrue
SlicingThis element introduces a set of slices on Observation.component. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • pattern @ code
  • 6. Observation.component:systolic
    Slice Namesystolic
    ShortSystolic Blood Pressure
    Control1..1
    Must Supporttrue
    8. Observation.component:systolic.code
    ShortSystolic Blood Pressure Code
    Control1..1
    Must Supporttrue
    Pattern Value{
      "coding" : [{
        "system" : "http://loinc.org",
        "code" : "8480-6"
      }]
    }
    10. Observation.component:systolic.valueQuantity
    ShortVital Sign Component Value
    TypeQuantity
    Must Supporttrue
    12. Observation.component:systolic.valueQuantity.value
    Control1..1
    Typedecimal
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    14. Observation.component:systolic.valueQuantity.unit
    Control1..1
    Typestring
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    16. Observation.component:systolic.valueQuantity.system
    Control1..1
    Typeuri
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Fixed Valuehttp://unitsofmeasure.org
    18. Observation.component:systolic.valueQuantity.code
    Control1..1
    Typecode
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Fixed Valuemm[Hg]
    20. Observation.component:diastolic
    Slice Namediastolic
    ShortDiastolic Blood Pressure
    Control1..1
    Must Supporttrue
    22. Observation.component:diastolic.code
    ShortDiastolic Blood Pressure Code
    Control1..1
    Must Supporttrue
    Pattern Value{
      "coding" : [{
        "system" : "http://loinc.org",
        "code" : "8462-4"
      }]
    }
    24. Observation.component:diastolic.valueQuantity
    ShortVital Sign Component Value
    TypeQuantity
    Must Supporttrue
    26. Observation.component:diastolic.valueQuantity.value
    Control1..1
    Typedecimal
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    28. Observation.component:diastolic.valueQuantity.unit
    Control1..1
    Typestring
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    30. Observation.component:diastolic.valueQuantity.system
    Control1..1
    Typeuri
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Fixed Valuehttp://unitsofmeasure.org
    32. Observation.component:diastolic.valueQuantity.code
    Control1..1
    Typecode
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Fixed Valuemm[Hg]

    Guidance on how to interpret the contents of this table can be found here

    0. Observation
    Definition

    The FHIR Vitals Signs profile sets minimum expectations for the Observation Resource to record, search and fetch the vital signs associated with a patient.


    Measurements and simple assertions made about a patient, device or other subject.

    ShortUS Core Blood Pressure ProfileMeasurements and simple assertions
    Comments

    Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

    Control0..*
    Is Modifierfalse
    Summaryfalse
    Alternate NamesVital Signs, Measurement, Results, Tests
    Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
    dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
    dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
    dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
    dom-6: A resource should have narrative for robust management (text.`div`.exists())
    obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
    obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
    vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. ((component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()))
    obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
    obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
    2. Observation.implicitRules
    Definition

    A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

    ShortA set of rules under which this content was created
    Comments

    Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

    Control0..1
    Typeuri
    Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Summarytrue
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    4. Observation.modifierExtension
    Definition

    May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

    Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

    ShortExtensions that cannot be ignored
    Comments

    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

    Control0..*
    TypeExtension
    Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
    Summaryfalse
    Requirements

    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.


    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

    Alternate Namesextensions, user content
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
    6. Observation.status
    Definition

    The status of the result value.

    Shortregistered | preliminary | final | amended +
    Comments

    This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

    Control1..1
    BindingThe codes SHALL be taken from ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1
    (required to http://hl7.org/fhir/ValueSet/observation-status|4.0.1)
    Typecode
    Is Modifiertrue because This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Summarytrue
    Requirements

    Need to track the status of individual results. Some results are finalized before the whole report is finalized.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    8. Observation.category
    Definition

    A code that classifies the general type of observation being made.

    ShortClassification of type of observation
    Comments

    In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

    Control10..*
    BindingThe codes SHOULD be taken from ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category
    (preferred to http://hl7.org/fhir/ValueSet/observation-category)

    Codes for high level observation categories.

    TypeCodeableConcept
    Is Modifierfalse
    Must Supporttrue
    Summaryfalse
    Requirements

    Used for filtering what observations are retrieved and displayed.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    SlicingThis element introduces a set of slices on Observation.category. The slices are unordered and Open, and can be differentiated using the following discriminators:
    • value @ coding.code
    • value @ coding.system
    • 10. Observation.category:VSCat
      Slice NameVSCat
      Definition

      A code that classifies the general type of observation being made.

      ShortClassification of type of observation
      Comments

      In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

      Control10..1*
      BindingThe codes SHOULD be taken from ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category
      (preferred to http://hl7.org/fhir/ValueSet/observation-category)

      Codes for high level observation categories.

      TypeCodeableConcept
      Is Modifierfalse
      Must Supporttrue
      Summaryfalse
      Requirements

      Used for filtering what observations are retrieved and displayed.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      12. Observation.category:VSCat.coding
      Definition

      A reference to a code defined by a terminology system.

      ShortCode defined by a terminology system
      Comments

      Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

      Control10..*
      TypeCoding
      Is Modifierfalse
      Must Supporttrue
      Summarytrue
      Requirements

      Allows for alternative encodings within a code system, and translations to other code systems.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      14. Observation.category:VSCat.coding.system
      Definition

      The identification of the code system that defines the meaning of the symbol in the code.

      ShortIdentity of the terminology system
      Comments

      The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.

      Control10..1
      Typeuri
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Summarytrue
      Requirements

      Need to be unambiguous about the source of the definition of the symbol.

      Fixed Valuehttp://terminology.hl7.org/CodeSystem/observation-category
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      16. Observation.category:VSCat.coding.code
      Definition

      A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination).

      ShortSymbol in syntax defined by the system
      Control10..1
      Typecode
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Summarytrue
      Requirements

      Need to refer to a particular code in the system.

      Fixed Valuevital-signs
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      18. Observation.code
      Definition

      Coded Responses from C-CDA Vital Sign Results.


      Describes what was observed. Sometimes this is called the observation "name".

      ShortBlood PressureType of observation (code / type)
      Comments

      All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

      Control1..1
      BindingUnless not suitable, these codes SHALL be taken from For example codes, see Vital Sign Result Type .http://hl7.org/fhir/ValueSet/observation-codes
      (extensible to http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62)

      Vital sign result types


      Codes identifying names of simple observations.

      TypeCodeableConcept
      Is Modifierfalse
      Must Supporttrue
      Summarytrue
      Requirements
      1. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).

      Knowing what kind of observation is being made is essential to understanding the observation.

      Alternate NamesName
      Pattern Value{
        "coding" : [{
          "system" : "http://loinc.org",
          "code" : "85354-9"
        }]
      }
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      20. Observation.subject
      Definition

      The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

      ShortWho and/or what the observation is about
      Comments

      One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.

      Control10..1
      TypeReference(US Core Patient Profile, Patient, Group, Device, Location)
      Is Modifierfalse
      Must Supporttrue
      Summarytrue
      Requirements

      Observations have no value if you don't know who or what they're about.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      22. Observation.effective[x]
      Definition

      Often just a dateTime for Vital Signs.


      The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

      ShortOften just a dateTime for Vital SignsClinically relevant time/time-period for observation
      Comments

      At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.


      At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

      Control10..1
      This element is affected by the following invariants: vs-1
      TypeChoice of: dateTime, Period, Timing, instant
      [x] NoteSee Choice of Data Types for further information about how to use [x]
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Must Support TypesdateTime
      Summarytrue
      Requirements

      Knowing when an observation was deemed true is important to its relevance as well as determining trends.

      Alternate NamesOccurrence
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day ($this is dateTime implies $this.toString().length() >= 10)
      24. Observation.value[x]
      Definition

      Vital Signs value are typically recorded using the Quantity data type.


      The information determined as a result of making the observation, if the information has a simple value.

      ShortVital Signs ValueActual result
      Comments

      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: obs-7, vs-2
      BindingUnless not suitable, these codes SHALL be taken from For codes, see VitalSignsUnits
      (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

      Common UCUM units for recording Vital Signs.

      TypeChoice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period
      [x] NoteSee Choice of Data Types for further information about how to use [x]
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Must Support TypesQuantity
      Summarytrue
      Requirements
      1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      26. Observation.dataAbsentReason
      Definition

      Provides a reason why the expected value in the element Observation.value[x] is missing.

      ShortWhy the result is missing
      Comments

      Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory".

      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.

      Control0..1
      This element is affected by the following invariants: obs-6, vs-2
      BindingUnless not suitable, these codes SHALL be taken from DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason
      (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

      Codes specifying why the result (Observation.value[x]) is missing.

      TypeCodeableConcept
      Is Modifierfalse
      Must Supporttrue
      Summaryfalse
      Requirements

      For many results it is necessary to handle exceptional values in measurements.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      28. Observation.component
      Definition

      Used when reporting component observation such as systolic and diastolic blood pressure.


      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

      ShortComponent observationsComponent results
      Comments

      For a discussion on the ways Observations can be assembled in groups together see Notes below.


      For a discussion on the ways Observations can be assembled in groups together see Notes below.

      Control20..*
      TypeBackboneElement
      Is Modifierfalse
      Must Supporttrue
      Summarytrue
      Requirements

      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
      SlicingThis element introduces a set of slices on Observation.component. The slices are unordered and Open, and can be differentiated using the following discriminators:
      • pattern @ code
      • 30. Observation.component.modifierExtension
        Definition

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        ShortExtensions that cannot be ignored even if unrecognized
        Comments

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Control0..*
        TypeExtension
        Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Requirements

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.


        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Alternate Namesextensions, user content, modifiers
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        32. Observation.component.code
        Definition

        Describes what was observed. Sometimes this is called the observation "code".

        ShortCoded vital sign result typeType of component observation (code / type)
        Comments

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Control1..1
        BindingUnless not suitable, these codes SHALL be taken from For example codes, see Vital Sign Result Type .http://hl7.org/fhir/ValueSet/observation-codes
        (extensible to http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62)

        Vital sign result types


        Codes identifying names of simple observations.

        TypeCodeableConcept
        Is Modifierfalse
        Must Supporttrue
        Summarytrue
        Requirements

        Knowing what kind of observation is being made is essential to understanding the observation.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        34. Observation.component.value[x]
        Definition

        Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.


        The information determined as a result of making the observation, if the information has a simple value.

        ShortVital Sign Component ValueActual component result
        Comments

        Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


        Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

        Control0..1
        This element is affected by the following invariants: vs-3
        BindingUnless not suitable, these codes SHALL be taken from For codes, see VitalSignsUnits
        (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

        Common UCUM units for recording Vital Signs.

        TypeChoice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period
        [x] NoteSee Choice of Data Types for further information about how to use [x]
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Must Support TypesQuantity
        Summarytrue
        Requirements
        1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        36. Observation.component.dataAbsentReason
        Definition

        Provides a reason why the expected value in the element Observation.component.value[x] is missing.

        ShortWhy the component result is missing
        Comments

        "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

        The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

        Control0..1
        This element is affected by the following invariants: obs-6, vs-3
        BindingUnless not suitable, these codes SHALL be taken from DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason
        (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

        Codes specifying why the result (Observation.value[x]) is missing.

        TypeCodeableConcept
        Is Modifierfalse
        Must Supporttrue
        Summaryfalse
        Requirements

        For many results it is necessary to handle exceptional values in measurements.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        38. Observation.component:systolic
        Slice Namesystolic
        Definition

        Used when reporting component observation such as systolic and diastolic blood pressure.


        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        ShortSystolic Blood PressureComponent results
        Comments

        For a discussion on the ways Observations can be assembled in groups together see Notes below.


        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Control10..1*
        TypeBackboneElement
        Is Modifierfalse
        Must Supporttrue
        Summarytrue
        Requirements

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
        40. Observation.component:systolic.modifierExtension
        Definition

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        ShortExtensions that cannot be ignored even if unrecognized
        Comments

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Control0..*
        TypeExtension
        Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Requirements

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.


        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Alternate Namesextensions, user content, modifiers
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        42. Observation.component:systolic.code
        Definition

        Describes what was observed. Sometimes this is called the observation "code".

        ShortSystolic Blood Pressure CodeType of component observation (code / type)
        Comments

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Control1..1
        BindingUnless not suitable, these codes SHALL be taken from For example codes, see Vital Sign Result Type .http://hl7.org/fhir/ValueSet/observation-codes
        (extensible to http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62)

        Vital sign result types


        Codes identifying names of simple observations.

        TypeCodeableConcept
        Is Modifierfalse
        Must Supporttrue
        Summarytrue
        Requirements

        Knowing what kind of observation is being made is essential to understanding the observation.

        Pattern Value{
          "coding" : [{
            "system" : "http://loinc.org",
            "code" : "8480-6"
          }]
        }
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        44. Observation.component:systolic.value[x]
        Definition

        Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.


        The information determined as a result of making the observation, if the information has a simple value.

        ShortVital Sign Component ValueActual component result
        Comments

        Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


        Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

        Control0..1
        This element is affected by the following invariants: vs-3
        BindingUnless not suitable, these codes SHALL be taken from For codes, see VitalSignsUnits
        (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

        Common UCUM units for recording Vital Signs.

        TypeQuantity, dateTime, boolean, string, SampledData, Period, Ratio, integer, time, Range, CodeableConcept
        [x] NoteSee Choice of Data Types for further information about how to use [x]
        Is Modifierfalse
        Must Supporttrue
        Must Support TypesQuantity
        Summarytrue
        Requirements
        1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        46. Observation.component:systolic.value[x].value
        Definition

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        ShortNumerical value (with implicit precision)
        Comments

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Control10..1
        Typedecimal
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Summarytrue
        Requirements

        Precision is handled implicitly in almost all cases of measurement.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        48. Observation.component:systolic.value[x].comparator
        Definition

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Short< | <= | >= | > - how to understand the value
        Control0..1
        BindingThe codes SHALL be taken from QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1)

        How the Quantity should be understood and represented.

        Typecode
        Is Modifiertrue because This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Requirements

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Meaning if MissingIf there is no comparator, then there is no modification of the value
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        50. Observation.component:systolic.value[x].unit
        Definition

        A human-readable form of the unit.

        ShortUnit representation
        Control10..1
        Typestring
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Summarytrue
        Requirements

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        52. Observation.component:systolic.value[x].system
        Definition

        The identification of the system that provides the coded form of the unit.

        ShortSystem that defines coded unit form
        Control10..1
        This element is affected by the following invariants: qty-3
        Typeuri
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Summarytrue
        Requirements

        Need to know the system that defines the coded form of the unit.

        Fixed Valuehttp://unitsofmeasure.org
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        54. Observation.component:systolic.value[x].code
        Definition

        A computer processable form of the unit in some unit representation system.

        ShortCoded form of the unit
        Comments

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Control10..1
        Typecode
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Summarytrue
        Requirements

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Fixed Valuemm[Hg]
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        56. Observation.component:systolic.dataAbsentReason
        Definition

        Provides a reason why the expected value in the element Observation.component.value[x] is missing.

        ShortWhy the component result is missing
        Comments

        "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

        The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

        Control0..1
        This element is affected by the following invariants: obs-6, vs-3
        BindingUnless not suitable, these codes SHALL be taken from DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason
        (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

        Codes specifying why the result (Observation.value[x]) is missing.

        TypeCodeableConcept
        Is Modifierfalse
        Must Supporttrue
        Summaryfalse
        Requirements

        For many results it is necessary to handle exceptional values in measurements.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        58. Observation.component:diastolic
        Slice Namediastolic
        Definition

        Used when reporting component observation such as systolic and diastolic blood pressure.


        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        ShortDiastolic Blood PressureComponent results
        Comments

        For a discussion on the ways Observations can be assembled in groups together see Notes below.


        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Control10..1*
        TypeBackboneElement
        Is Modifierfalse
        Must Supporttrue
        Summarytrue
        Requirements

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
        60. Observation.component:diastolic.modifierExtension
        Definition

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        ShortExtensions that cannot be ignored even if unrecognized
        Comments

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Control0..*
        TypeExtension
        Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Requirements

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.


        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Alternate Namesextensions, user content, modifiers
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        62. Observation.component:diastolic.code
        Definition

        Describes what was observed. Sometimes this is called the observation "code".

        ShortDiastolic Blood Pressure CodeType of component observation (code / type)
        Comments

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Control1..1
        BindingUnless not suitable, these codes SHALL be taken from For example codes, see Vital Sign Result Type .http://hl7.org/fhir/ValueSet/observation-codes
        (extensible to http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62)

        Vital sign result types


        Codes identifying names of simple observations.

        TypeCodeableConcept
        Is Modifierfalse
        Must Supporttrue
        Summarytrue
        Requirements

        Knowing what kind of observation is being made is essential to understanding the observation.

        Pattern Value{
          "coding" : [{
            "system" : "http://loinc.org",
            "code" : "8462-4"
          }]
        }
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        64. Observation.component:diastolic.value[x]
        Definition

        Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.


        The information determined as a result of making the observation, if the information has a simple value.

        ShortVital Sign Component ValueActual component result
        Comments

        Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


        Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

        Control0..1
        This element is affected by the following invariants: vs-3
        BindingUnless not suitable, these codes SHALL be taken from For codes, see VitalSignsUnits
        (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

        Common UCUM units for recording Vital Signs.

        TypeQuantity, dateTime, boolean, string, SampledData, Period, Ratio, integer, time, Range, CodeableConcept
        [x] NoteSee Choice of Data Types for further information about how to use [x]
        Is Modifierfalse
        Must Supporttrue
        Must Support TypesQuantity
        Summarytrue
        Requirements
        1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        66. Observation.component:diastolic.value[x].value
        Definition

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        ShortNumerical value (with implicit precision)
        Comments

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Control10..1
        Typedecimal
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Summarytrue
        Requirements

        Precision is handled implicitly in almost all cases of measurement.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        68. Observation.component:diastolic.value[x].comparator
        Definition

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Short< | <= | >= | > - how to understand the value
        Control0..1
        BindingThe codes SHALL be taken from QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1)

        How the Quantity should be understood and represented.

        Typecode
        Is Modifiertrue because This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Requirements

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Meaning if MissingIf there is no comparator, then there is no modification of the value
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        70. Observation.component:diastolic.value[x].unit
        Definition

        A human-readable form of the unit.

        ShortUnit representation
        Control10..1
        Typestring
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Summarytrue
        Requirements

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        72. Observation.component:diastolic.value[x].system
        Definition

        The identification of the system that provides the coded form of the unit.

        ShortSystem that defines coded unit form
        Control10..1
        This element is affected by the following invariants: qty-3
        Typeuri
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Summarytrue
        Requirements

        Need to know the system that defines the coded form of the unit.

        Fixed Valuehttp://unitsofmeasure.org
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        74. Observation.component:diastolic.value[x].code
        Definition

        A computer processable form of the unit in some unit representation system.

        ShortCoded form of the unit
        Comments

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Control10..1
        Typecode
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Summarytrue
        Requirements

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Fixed Valuemm[Hg]
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        76. Observation.component:diastolic.dataAbsentReason
        Definition

        Provides a reason why the expected value in the element Observation.component.value[x] is missing.

        ShortWhy the component result is missing
        Comments

        "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

        The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

        Control0..1
        This element is affected by the following invariants: obs-6, vs-3
        BindingUnless not suitable, these codes SHALL be taken from DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason
        (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

        Codes specifying why the result (Observation.value[x]) is missing.

        TypeCodeableConcept
        Is Modifierfalse
        Must Supporttrue
        Summaryfalse
        Requirements

        For many results it is necessary to handle exceptional values in measurements.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))

        Guidance on how to interpret the contents of this table can be found here

        0. Observation
        Definition

        The FHIR Vitals Signs profile sets minimum expectations for the Observation Resource to record, search and fetch the vital signs associated with a patient.

        ShortUS Core Blood Pressure Profile
        Comments

        Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

        Control0..*
        Is Modifierfalse
        Summaryfalse
        Alternate NamesVital Signs, Measurement, Results, Tests
        Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
        dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
        dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
        dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
        dom-6: A resource should have narrative for robust management (text.`div`.exists())
        obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
        obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
        vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. ((component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()))
        2. Observation.id
        Definition

        The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes.

        ShortLogical id of this artifact
        Comments

        The only time that a resource does not have an id is when it is being submitted to the server using a create operation.

        Control0..1
        Typeid
        Is Modifierfalse
        Summarytrue
        4. Observation.meta
        Definition

        The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.

        ShortMetadata about the resource
        Control0..1
        TypeMeta
        Is Modifierfalse
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        6. Observation.implicitRules
        Definition

        A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

        ShortA set of rules under which this content was created
        Comments

        Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

        Control0..1
        Typeuri
        Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summarytrue
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        8. Observation.language
        Definition

        The base language in which the resource is written.

        ShortLanguage of the resource content
        Comments

        Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).

        Control0..1
        BindingThe codes SHOULD be taken from CommonLanguages
        (preferred to http://hl7.org/fhir/ValueSet/languages)

        A human language.

        Additional BindingsPurpose
        AllLanguagesMax Binding
        Typecode
        Is Modifierfalse
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Summaryfalse
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        10. Observation.text
        Definition

        A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety.

        ShortText summary of the resource, for human interpretation
        Comments

        Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.

        Control0..1
        TypeNarrative
        Is Modifierfalse
        Summaryfalse
        Alternate Namesnarrative, html, xhtml, display
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        12. Observation.contained
        Definition

        These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope.

        ShortContained, inline Resources
        Comments

        This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.

        Control0..*
        TypeResource
        Is Modifierfalse
        Summaryfalse
        Alternate Namesinline resources, anonymous resources, contained resources
        14. Observation.extension
        Definition

        May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

        ShortAdditional content defined by implementations
        Comments

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Control0..*
        TypeExtension
        Is Modifierfalse
        Summaryfalse
        Alternate Namesextensions, user content
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        16. Observation.modifierExtension
        Definition

        May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        ShortExtensions that cannot be ignored
        Comments

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Control0..*
        TypeExtension
        Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
        Summaryfalse
        Requirements

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Alternate Namesextensions, user content
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        18. Observation.identifier
        Definition

        A unique identifier assigned to this observation.

        ShortBusiness Identifier for observation
        NoteThis is a business identifier, not a resource identifier (see discussion)
        Control0..*
        TypeIdentifier
        Is Modifierfalse
        Summarytrue
        Requirements

        Allows observations to be distinguished and referenced.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        20. Observation.basedOn
        Definition

        A plan, proposal or order that is fulfilled in whole or in part by this event. For example, a MedicationRequest may require a patient to have laboratory test performed before it is dispensed.

        ShortFulfills plan, proposal or order
        Control0..*
        TypeReference(CarePlan, DeviceRequest, ImmunizationRecommendation, MedicationRequest, NutritionOrder, ServiceRequest)
        Is Modifierfalse
        Summarytrue
        Requirements

        Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon.

        Alternate NamesFulfills
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        22. Observation.partOf
        Definition

        A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure.

        ShortPart of referenced event
        Comments

        To link an Observation to an Encounter use encounter. See the Notes below for guidance on referencing another Observation.

        Control0..*
        TypeReference(MedicationAdministration, MedicationDispense, MedicationStatement, Procedure, Immunization, ImagingStudy)
        Is Modifierfalse
        Summarytrue
        Alternate NamesContainer
        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        24. Observation.status
        Definition

        The status of the result value.

        Shortregistered | preliminary | final | amended +
        Comments

        This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

        Control1..1
        BindingThe codes SHALL be taken from ObservationStatus
        (required to http://hl7.org/fhir/ValueSet/observation-status|4.0.1)
        Typecode
        Is Modifiertrue because This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
        Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
        Must Supporttrue
        Summarytrue
        Requirements

        Need to track the status of individual results. Some results are finalized before the whole report is finalized.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        26. Observation.category
        Definition

        A code that classifies the general type of observation being made.

        ShortClassification of type of observation
        Comments

        In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

        Control1..*
        BindingThe codes SHOULD be taken from ObservationCategoryCodes
        (preferred to http://hl7.org/fhir/ValueSet/observation-category)

        Codes for high level observation categories.

        TypeCodeableConcept
        Is Modifierfalse
        Must Supporttrue
        Summaryfalse
        Requirements

        Used for filtering what observations are retrieved and displayed.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        SlicingThis element introduces a set of slices on Observation.category. The slices are unordered and Open, and can be differentiated using the following discriminators:
        • value @ coding.code
        • value @ coding.system
        • 28. Observation.category:VSCat
          Slice NameVSCat
          Definition

          A code that classifies the general type of observation being made.

          ShortClassification of type of observation
          Comments

          In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

          Control1..1
          BindingThe codes SHOULD be taken from ObservationCategoryCodes
          (preferred to http://hl7.org/fhir/ValueSet/observation-category)

          Codes for high level observation categories.

          TypeCodeableConcept
          Is Modifierfalse
          Must Supporttrue
          Summaryfalse
          Requirements

          Used for filtering what observations are retrieved and displayed.

          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          30. Observation.category:VSCat.id
          Definition

          Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

          ShortUnique id for inter-element referencing
          Control0..1
          Typestring
          Is Modifierfalse
          XML FormatIn the XML format, this property is represented as an attribute.
          Summaryfalse
          32. Observation.category:VSCat.extension
          Definition

          May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

          ShortAdditional content defined by implementations
          Comments

          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

          Control0..*
          TypeExtension
          Is Modifierfalse
          Summaryfalse
          Alternate Namesextensions, user content
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          SlicingThis element introduces a set of slices on Observation.category.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
          • value @ url
          • 34. Observation.category:VSCat.coding
            Definition

            A reference to a code defined by a terminology system.

            ShortCode defined by a terminology system
            Comments

            Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

            Control1..*
            TypeCoding
            Is Modifierfalse
            Must Supporttrue
            Summarytrue
            Requirements

            Allows for alternative encodings within a code system, and translations to other code systems.

            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            36. Observation.category:VSCat.coding.id
            Definition

            Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

            ShortUnique id for inter-element referencing
            Control0..1
            Typestring
            Is Modifierfalse
            XML FormatIn the XML format, this property is represented as an attribute.
            Summaryfalse
            38. Observation.category:VSCat.coding.extension
            Definition

            May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

            ShortAdditional content defined by implementations
            Comments

            There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

            Control0..*
            TypeExtension
            Is Modifierfalse
            Summaryfalse
            Alternate Namesextensions, user content
            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
            SlicingThis element introduces a set of slices on Observation.category.coding.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
            • value @ url
            • 40. Observation.category:VSCat.coding.system
              Definition

              The identification of the code system that defines the meaning of the symbol in the code.

              ShortIdentity of the terminology system
              Comments

              The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.

              Control1..1
              Typeuri
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Must Supporttrue
              Summarytrue
              Requirements

              Need to be unambiguous about the source of the definition of the symbol.

              Fixed Valuehttp://terminology.hl7.org/CodeSystem/observation-category
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              42. Observation.category:VSCat.coding.version
              Definition

              The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged.

              ShortVersion of the system - if relevant
              Comments

              Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.

              NoteThis is a business versionId, not a resource version id (see discussion)
              Control0..1
              Typestring
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Summarytrue
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              44. Observation.category:VSCat.coding.code
              Definition

              A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination).

              ShortSymbol in syntax defined by the system
              Control1..1
              Typecode
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Must Supporttrue
              Summarytrue
              Requirements

              Need to refer to a particular code in the system.

              Fixed Valuevital-signs
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              46. Observation.category:VSCat.coding.display
              Definition

              A representation of the meaning of the code in the system, following the rules of the system.

              ShortRepresentation defined by the system
              Control0..1
              Typestring
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Summarytrue
              Requirements

              Need to be able to carry a human-readable meaning of the code for readers that do not know the system.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              48. Observation.category:VSCat.coding.userSelected
              Definition

              Indicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays).

              ShortIf this coding was chosen directly by the user
              Comments

              Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.

              Control0..1
              Typeboolean
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Summarytrue
              Requirements

              This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              50. Observation.category:VSCat.text
              Definition

              A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user.

              ShortPlain text representation of the concept
              Comments

              Very often the text is the same as a displayName of one of the codings.

              Control0..1
              Typestring
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Summarytrue
              Requirements

              The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              52. Observation.code
              Definition

              Coded Responses from C-CDA Vital Sign Results.

              ShortBlood Pressure
              Comments

              All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

              Control1..1
              BindingUnless not suitable, these codes SHALL be taken from Vital Sign Result Type .
              (extensible to http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62)

              Vital sign result types

              TypeCodeableConcept
              Is Modifierfalse
              Must Supporttrue
              Summarytrue
              Requirements
              1. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).
              Alternate NamesName
              Pattern Value{
                "coding" : [{
                  "system" : "http://loinc.org",
                  "code" : "85354-9"
                }]
              }
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              54. Observation.subject
              Definition

              The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

              ShortWho and/or what the observation is about
              Comments

              One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.

              Control1..1
              TypeReference(US Core Patient Profile)
              Is Modifierfalse
              Must Supporttrue
              Summarytrue
              Requirements

              Observations have no value if you don't know who or what they're about.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              56. Observation.focus
              Definition

              The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.

              ShortWhat the observation is about, when it is not about the subject of record
              Comments

              Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use specimen if a reference to a specimen is required. If a code is required instead of a resource use either bodysite for bodysites or the standard extension focusCode.

              Control0..*
              TypeReference(Resource)
              Is Modifierfalse
              Summarytrue
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              58. Observation.encounter
              Definition

              The healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made.

              ShortHealthcare event during which this observation is made
              Comments

              This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).

              Control0..1
              TypeReference(Encounter)
              Is Modifierfalse
              Summarytrue
              Requirements

              For some observations it may be important to know the link between an observation and a particular encounter.

              Alternate NamesContext
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              60. Observation.effective[x]
              Definition

              Often just a dateTime for Vital Signs.

              ShortOften just a dateTime for Vital Signs
              Comments

              At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

              Control1..1
              This element is affected by the following invariants: vs-1
              TypeChoice of: dateTime, Period
              [x] NoteSee Choice of Data Types for further information about how to use [x]
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Must Supporttrue
              Must Support TypesdateTime
              Summarytrue
              Requirements

              Knowing when an observation was deemed true is important to its relevance as well as determining trends.

              Alternate NamesOccurrence
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day ($this is dateTime implies $this.toString().length() >= 10)
              62. Observation.issued
              Definition

              The date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified.

              ShortDate/Time this version was made available
              Comments

              For Observations that don’t require review and verification, it may be the same as the lastUpdated time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the lastUpdated time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.

              Control0..1
              Typeinstant
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Summarytrue
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              64. Observation.performer
              Definition

              Who was responsible for asserting the observed value as "true".

              ShortWho is responsible for the observation
              Control0..*
              TypeReference(Practitioner, PractitionerRole, Organization, CareTeam, Patient, RelatedPerson)
              Is Modifierfalse
              Summarytrue
              Requirements

              May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              66. Observation.value[x]
              Definition

              Vital Signs value are typically recorded using the Quantity data type.

              ShortVital Signs Value
              Comments

              An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

              Control0..1
              This element is affected by the following invariants: obs-7, vs-2
              BindingUnless not suitable, these codes SHALL be taken from VitalSignsUnits
              (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

              Common UCUM units for recording Vital Signs.

              TypeChoice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period
              [x] NoteSee Choice of Data Types for further information about how to use [x]
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Must Supporttrue
              Must Support TypesQuantity
              Summarytrue
              Requirements
              1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              68. Observation.dataAbsentReason
              Definition

              Provides a reason why the expected value in the element Observation.value[x] is missing.

              ShortWhy the result is missing
              Comments

              Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory".

              The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.

              Control0..1
              This element is affected by the following invariants: obs-6, vs-2
              BindingUnless not suitable, these codes SHALL be taken from DataAbsentReason
              (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

              Codes specifying why the result (Observation.value[x]) is missing.

              TypeCodeableConcept
              Is Modifierfalse
              Must Supporttrue
              Summaryfalse
              Requirements

              For many results it is necessary to handle exceptional values in measurements.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              70. Observation.interpretation
              Definition

              A categorical assessment of an observation value. For example, high, low, normal.

              ShortHigh, low, normal, etc.
              Comments

              Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

              Control0..*
              BindingUnless not suitable, these codes SHALL be taken from ObservationInterpretationCodes
              (extensible to http://hl7.org/fhir/ValueSet/observation-interpretation)

              Codes identifying interpretations of observations.

              TypeCodeableConcept
              Is Modifierfalse
              Summaryfalse
              Requirements

              For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

              Alternate NamesAbnormal Flag
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              72. Observation.note
              Definition

              Comments about the observation or the results.

              ShortComments about the observation
              Comments

              May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.

              Control0..*
              TypeAnnotation
              Is Modifierfalse
              Summaryfalse
              Requirements

              Need to be able to provide free text additional information.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              74. Observation.bodySite
              Definition

              Indicates the site on the subject's body where the observation was made (i.e. the target site).

              ShortObserved body part
              Comments

              Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component.

              If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension bodySite.

              Control0..1
              BindingFor example codes, see SNOMEDCTBodyStructures
              (example to http://hl7.org/fhir/ValueSet/body-site)

              Codes describing anatomical locations. May include laterality.

              TypeCodeableConcept
              Is Modifierfalse
              Summaryfalse
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              76. Observation.method
              Definition

              Indicates the mechanism used to perform the observation.

              ShortHow it was done
              Comments

              Only used if not implicit in code for Observation.code.

              Control0..1
              BindingFor example codes, see ObservationMethods
              (example to http://hl7.org/fhir/ValueSet/observation-methods)

              Methods for simple observations.

              TypeCodeableConcept
              Is Modifierfalse
              Summaryfalse
              Requirements

              In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              78. Observation.specimen
              Definition

              The specimen that was used when this observation was made.

              ShortSpecimen used for this observation
              Comments

              Should only be used if not implicit in code found in Observation.code. Observations are not made on specimens themselves; they are made on a subject, but in many cases by the means of a specimen. Note that although specimens are often involved, they are not always tracked and reported explicitly. Also note that observation resources may be used in contexts that track the specimen explicitly (e.g. Diagnostic Report).

              Control0..1
              TypeReference(Specimen)
              Is Modifierfalse
              Summaryfalse
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              80. Observation.device
              Definition

              The device used to generate the observation data.

              Short(Measurement) Device
              Comments

              Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant.

              Control0..1
              TypeReference(Device, DeviceMetric)
              Is Modifierfalse
              Summaryfalse
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              82. Observation.referenceRange
              Definition

              Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two referenceRange elements would be used.

              ShortProvides guide for interpretation
              Comments

              Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

              Control0..*
              TypeBackboneElement
              Is Modifierfalse
              Summaryfalse
              Requirements

              Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
              84. Observation.referenceRange.id
              Definition

              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

              ShortUnique id for inter-element referencing
              Control0..1
              Typestring
              Is Modifierfalse
              XML FormatIn the XML format, this property is represented as an attribute.
              Summaryfalse
              86. Observation.referenceRange.extension
              Definition

              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

              ShortAdditional content defined by implementations
              Comments

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Control0..*
              TypeExtension
              Is Modifierfalse
              Summaryfalse
              Alternate Namesextensions, user content
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              88. Observation.referenceRange.modifierExtension
              Definition

              May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

              ShortExtensions that cannot be ignored even if unrecognized
              Comments

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Control0..*
              TypeExtension
              Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
              Summarytrue
              Requirements

              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

              Alternate Namesextensions, user content, modifiers
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              90. Observation.referenceRange.low
              Definition

              The value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3).

              ShortLow Range, if relevant
              Control0..1
              This element is affected by the following invariants: obs-3
              TypeQuantity(SimpleQuantity)
              Is Modifierfalse
              Summaryfalse
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              92. Observation.referenceRange.high
              Definition

              The value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3).

              ShortHigh Range, if relevant
              Control0..1
              This element is affected by the following invariants: obs-3
              TypeQuantity(SimpleQuantity)
              Is Modifierfalse
              Summaryfalse
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              94. Observation.referenceRange.type
              Definition

              Codes to indicate the what part of the targeted reference population it applies to. For example, the normal or therapeutic range.

              ShortReference range qualifier
              Comments

              This SHOULD be populated if there is more than one range. If this element is not present then the normal range is assumed.

              Control0..1
              BindingThe codes SHOULD be taken from ObservationReferenceRangeMeaningCodes
              (preferred to http://hl7.org/fhir/ValueSet/referencerange-meaning)

              Code for the meaning of a reference range.

              TypeCodeableConcept
              Is Modifierfalse
              Summaryfalse
              Requirements

              Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, etc., - for proper interpretation.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              96. Observation.referenceRange.appliesTo
              Definition

              Codes to indicate the target population this reference range applies to. For example, a reference range may be based on the normal population or a particular sex or race. Multiple appliesTo are interpreted as an "AND" of the target populations. For example, to represent a target population of African American females, both a code of female and a code for African American would be used.

              ShortReference range population
              Comments

              This SHOULD be populated if there is more than one range. If this element is not present then the normal population is assumed.

              Control0..*
              BindingFor example codes, see ObservationReferenceRangeAppliesToCodes
              (example to http://hl7.org/fhir/ValueSet/referencerange-appliesto)

              Codes identifying the population the reference range applies to.

              TypeCodeableConcept
              Is Modifierfalse
              Summaryfalse
              Requirements

              Need to be able to identify the target population for proper interpretation.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              98. Observation.referenceRange.age
              Definition

              The age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so.

              ShortApplicable age range, if relevant
              Control0..1
              TypeRange
              Is Modifierfalse
              Summaryfalse
              Requirements

              Some analytes vary greatly over age.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              100. Observation.referenceRange.text
              Definition

              Text based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals".

              ShortText based reference range in an observation
              Control0..1
              Typestring
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Summaryfalse
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              102. Observation.hasMember
              Definition

              Used when reporting vital signs panel components.

              ShortUsed when reporting vital signs panel components
              Comments

              When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

              Control0..*
              TypeReference(QuestionnaireResponse, MolecularSequence, Vital Signs Profile)
              Is Modifierfalse
              Summarytrue
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              104. Observation.derivedFrom
              Definition

              The target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image.

              ShortRelated measurements the observation is made from
              Comments

              All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below.

              Control0..*
              TypeReference(DocumentReference, ImagingStudy, Media, QuestionnaireResponse, MolecularSequence, Vital Signs Profile)
              Is Modifierfalse
              Summarytrue
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              106. Observation.component
              Definition

              Used when reporting component observation such as systolic and diastolic blood pressure.

              ShortComponent observations
              Comments

              For a discussion on the ways Observations can be assembled in groups together see Notes below.

              Control2..*
              TypeBackboneElement
              Is Modifierfalse
              Must Supporttrue
              Summarytrue
              Requirements

              Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
              SlicingThis element introduces a set of slices on Observation.component. The slices are unordered and Open, and can be differentiated using the following discriminators:
              • pattern @ code
              • 108. Observation.component.id
                Definition

                Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                ShortUnique id for inter-element referencing
                Control0..1
                Typestring
                Is Modifierfalse
                XML FormatIn the XML format, this property is represented as an attribute.
                Summaryfalse
                110. Observation.component.extension
                Definition

                May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                ShortAdditional content defined by implementations
                Comments

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Control0..*
                TypeExtension
                Is Modifierfalse
                Summaryfalse
                Alternate Namesextensions, user content
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                112. Observation.component.modifierExtension
                Definition

                May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                ShortExtensions that cannot be ignored even if unrecognized
                Comments

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Control0..*
                TypeExtension
                Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                Summarytrue
                Requirements

                Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                Alternate Namesextensions, user content, modifiers
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                114. Observation.component.code
                Definition

                Describes what was observed. Sometimes this is called the observation "code".

                ShortCoded vital sign result type
                Comments

                All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                Control1..1
                BindingUnless not suitable, these codes SHALL be taken from Vital Sign Result Type .
                (extensible to http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62)

                Vital sign result types

                TypeCodeableConcept
                Is Modifierfalse
                Must Supporttrue
                Summarytrue
                Requirements

                Knowing what kind of observation is being made is essential to understanding the observation.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                116. Observation.component.value[x]
                Definition

                Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.

                ShortVital Sign Component Value
                Comments

                Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

                Control0..1
                This element is affected by the following invariants: vs-3
                BindingUnless not suitable, these codes SHALL be taken from VitalSignsUnits
                (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

                Common UCUM units for recording Vital Signs.

                TypeChoice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period
                [x] NoteSee Choice of Data Types for further information about how to use [x]
                Is Modifierfalse
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Must Supporttrue
                Must Support TypesQuantity
                Summarytrue
                Requirements
                1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                118. Observation.component.dataAbsentReason
                Definition

                Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                ShortWhy the component result is missing
                Comments

                "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                Control0..1
                This element is affected by the following invariants: obs-6, vs-3
                BindingUnless not suitable, these codes SHALL be taken from DataAbsentReason
                (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

                Codes specifying why the result (Observation.value[x]) is missing.

                TypeCodeableConcept
                Is Modifierfalse
                Must Supporttrue
                Summaryfalse
                Requirements

                For many results it is necessary to handle exceptional values in measurements.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                120. Observation.component.interpretation
                Definition

                A categorical assessment of an observation value. For example, high, low, normal.

                ShortHigh, low, normal, etc.
                Comments

                Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                Control0..*
                BindingUnless not suitable, these codes SHALL be taken from ObservationInterpretationCodes
                (extensible to http://hl7.org/fhir/ValueSet/observation-interpretation)

                Codes identifying interpretations of observations.

                TypeCodeableConcept
                Is Modifierfalse
                Summaryfalse
                Requirements

                For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                Alternate NamesAbnormal Flag
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                122. Observation.component.referenceRange
                Definition

                Guidance on how to interpret the value by comparison to a normal or recommended range.

                ShortProvides guide for interpretation of component result
                Comments

                Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                Control0..*
                TypeSee ttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                Is Modifierfalse
                Summaryfalse
                Requirements

                Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                124. Observation.component:systolic
                Slice Namesystolic
                Definition

                Used when reporting component observation such as systolic and diastolic blood pressure.

                ShortSystolic Blood Pressure
                Comments

                For a discussion on the ways Observations can be assembled in groups together see Notes below.

                Control1..1
                TypeBackboneElement
                Is Modifierfalse
                Must Supporttrue
                Summarytrue
                Requirements

                Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
                126. Observation.component:systolic.id
                Definition

                Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                ShortUnique id for inter-element referencing
                Control0..1
                Typestring
                Is Modifierfalse
                XML FormatIn the XML format, this property is represented as an attribute.
                Summaryfalse
                128. Observation.component:systolic.extension
                Definition

                May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                ShortAdditional content defined by implementations
                Comments

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Control0..*
                TypeExtension
                Is Modifierfalse
                Summaryfalse
                Alternate Namesextensions, user content
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                130. Observation.component:systolic.modifierExtension
                Definition

                May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                ShortExtensions that cannot be ignored even if unrecognized
                Comments

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Control0..*
                TypeExtension
                Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                Summarytrue
                Requirements

                Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                Alternate Namesextensions, user content, modifiers
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                132. Observation.component:systolic.code
                Definition

                Describes what was observed. Sometimes this is called the observation "code".

                ShortSystolic Blood Pressure Code
                Comments

                All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                Control1..1
                BindingUnless not suitable, these codes SHALL be taken from Vital Sign Result Type .
                (extensible to http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62)

                Vital sign result types

                TypeCodeableConcept
                Is Modifierfalse
                Must Supporttrue
                Summarytrue
                Requirements

                Knowing what kind of observation is being made is essential to understanding the observation.

                Pattern Value{
                  "coding" : [{
                    "system" : "http://loinc.org",
                    "code" : "8480-6"
                  }]
                }
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                134. Observation.component:systolic.value[x]
                Definition

                Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.

                ShortVital Sign Component Value
                Comments

                Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

                Control0..1
                This element is affected by the following invariants: vs-3
                BindingUnless not suitable, these codes SHALL be taken from VitalSignsUnits
                (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

                Common UCUM units for recording Vital Signs.

                TypeQuantity
                [x] NoteSee Choice of Data Types for further information about how to use [x]
                Is Modifierfalse
                Must Supporttrue
                Must Support TypesQuantity
                Summarytrue
                Requirements
                1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                136. Observation.component:systolic.value[x].id
                Definition

                Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                ShortUnique id for inter-element referencing
                Control0..1
                Typestring
                Is Modifierfalse
                XML FormatIn the XML format, this property is represented as an attribute.
                Summaryfalse
                138. Observation.component:systolic.value[x].extension
                Definition

                May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                ShortAdditional content defined by implementations
                Comments

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Control0..*
                TypeExtension
                Is Modifierfalse
                Summaryfalse
                Alternate Namesextensions, user content
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                SlicingThis element introduces a set of slices on Observation.component.value[x].extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
                • value @ url
                • 140. Observation.component:systolic.value[x].value
                  Definition

                  The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                  ShortNumerical value (with implicit precision)
                  Comments

                  The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                  Control1..1
                  Typedecimal
                  Is Modifierfalse
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Precision is handled implicitly in almost all cases of measurement.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  142. Observation.component:systolic.value[x].comparator
                  Definition

                  How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                  Short< | <= | >= | > - how to understand the value
                  Control0..1
                  BindingThe codes SHALL be taken from QuantityComparator
                  (required to http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1)

                  How the Quantity should be understood and represented.

                  Typecode
                  Is Modifiertrue because This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Summarytrue
                  Requirements

                  Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                  Meaning if MissingIf there is no comparator, then there is no modification of the value
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  144. Observation.component:systolic.value[x].unit
                  Definition

                  A human-readable form of the unit.

                  ShortUnit representation
                  Control1..1
                  Typestring
                  Is Modifierfalse
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  146. Observation.component:systolic.value[x].system
                  Definition

                  The identification of the system that provides the coded form of the unit.

                  ShortSystem that defines coded unit form
                  Control1..1
                  This element is affected by the following invariants: qty-3
                  Typeuri
                  Is Modifierfalse
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Need to know the system that defines the coded form of the unit.

                  Fixed Valuehttp://unitsofmeasure.org
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  148. Observation.component:systolic.value[x].code
                  Definition

                  A computer processable form of the unit in some unit representation system.

                  ShortCoded form of the unit
                  Comments

                  The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                  Control1..1
                  Typecode
                  Is Modifierfalse
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                  Fixed Valuemm[Hg]
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  150. Observation.component:systolic.dataAbsentReason
                  Definition

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  ShortWhy the component result is missing
                  Comments

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Control0..1
                  This element is affected by the following invariants: obs-6, vs-3
                  BindingUnless not suitable, these codes SHALL be taken from DataAbsentReason
                  (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

                  Codes specifying why the result (Observation.value[x]) is missing.

                  TypeCodeableConcept
                  Is Modifierfalse
                  Must Supporttrue
                  Summaryfalse
                  Requirements

                  For many results it is necessary to handle exceptional values in measurements.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  152. Observation.component:systolic.interpretation
                  Definition

                  A categorical assessment of an observation value. For example, high, low, normal.

                  ShortHigh, low, normal, etc.
                  Comments

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Control0..*
                  BindingUnless not suitable, these codes SHALL be taken from ObservationInterpretationCodes
                  (extensible to http://hl7.org/fhir/ValueSet/observation-interpretation)

                  Codes identifying interpretations of observations.

                  TypeCodeableConcept
                  Is Modifierfalse
                  Summaryfalse
                  Requirements

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Alternate NamesAbnormal Flag
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  154. Observation.component:systolic.referenceRange
                  Definition

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  ShortProvides guide for interpretation of component result
                  Comments

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Control0..*
                  TypeSee ttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Is Modifierfalse
                  Summaryfalse
                  Requirements

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  156. Observation.component:diastolic
                  Slice Namediastolic
                  Definition

                  Used when reporting component observation such as systolic and diastolic blood pressure.

                  ShortDiastolic Blood Pressure
                  Comments

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Control1..1
                  TypeBackboneElement
                  Is Modifierfalse
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
                  158. Observation.component:diastolic.id
                  Definition

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  ShortUnique id for inter-element referencing
                  Control0..1
                  Typestring
                  Is Modifierfalse
                  XML FormatIn the XML format, this property is represented as an attribute.
                  Summaryfalse
                  160. Observation.component:diastolic.extension
                  Definition

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  ShortAdditional content defined by implementations
                  Comments

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Control0..*
                  TypeExtension
                  Is Modifierfalse
                  Summaryfalse
                  Alternate Namesextensions, user content
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  162. Observation.component:diastolic.modifierExtension
                  Definition

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  ShortExtensions that cannot be ignored even if unrecognized
                  Comments

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Control0..*
                  TypeExtension
                  Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Requirements

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Alternate Namesextensions, user content, modifiers
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  164. Observation.component:diastolic.code
                  Definition

                  Describes what was observed. Sometimes this is called the observation "code".

                  ShortDiastolic Blood Pressure Code
                  Comments

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Control1..1
                  BindingUnless not suitable, these codes SHALL be taken from Vital Sign Result Type .
                  (extensible to http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62)

                  Vital sign result types

                  TypeCodeableConcept
                  Is Modifierfalse
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Pattern Value{
                    "coding" : [{
                      "system" : "http://loinc.org",
                      "code" : "8462-4"
                    }]
                  }
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  166. Observation.component:diastolic.value[x]
                  Definition

                  Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.

                  ShortVital Sign Component Value
                  Comments

                  Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

                  Control0..1
                  This element is affected by the following invariants: vs-3
                  BindingUnless not suitable, these codes SHALL be taken from VitalSignsUnits
                  (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

                  Common UCUM units for recording Vital Signs.

                  TypeQuantity
                  [x] NoteSee Choice of Data Types for further information about how to use [x]
                  Is Modifierfalse
                  Must Supporttrue
                  Must Support TypesQuantity
                  Summarytrue
                  Requirements
                  1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  168. Observation.component:diastolic.value[x].id
                  Definition

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  ShortUnique id for inter-element referencing
                  Control0..1
                  Typestring
                  Is Modifierfalse
                  XML FormatIn the XML format, this property is represented as an attribute.
                  Summaryfalse
                  170. Observation.component:diastolic.value[x].extension
                  Definition

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  ShortAdditional content defined by implementations
                  Comments

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Control0..*
                  TypeExtension
                  Is Modifierfalse
                  Summaryfalse
                  Alternate Namesextensions, user content
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  SlicingThis element introduces a set of slices on Observation.component.value[x].extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
                  • value @ url
                  • 172. Observation.component:diastolic.value[x].value
                    Definition

                    The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                    ShortNumerical value (with implicit precision)
                    Comments

                    The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                    Control1..1
                    Typedecimal
                    Is Modifierfalse
                    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                    Must Supporttrue
                    Summarytrue
                    Requirements

                    Precision is handled implicitly in almost all cases of measurement.

                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    174. Observation.component:diastolic.value[x].comparator
                    Definition

                    How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                    Short< | <= | >= | > - how to understand the value
                    Control0..1
                    BindingThe codes SHALL be taken from QuantityComparator
                    (required to http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1)

                    How the Quantity should be understood and represented.

                    Typecode
                    Is Modifiertrue because This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                    Summarytrue
                    Requirements

                    Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                    Meaning if MissingIf there is no comparator, then there is no modification of the value
                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    176. Observation.component:diastolic.value[x].unit
                    Definition

                    A human-readable form of the unit.

                    ShortUnit representation
                    Control1..1
                    Typestring
                    Is Modifierfalse
                    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                    Must Supporttrue
                    Summarytrue
                    Requirements

                    There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    178. Observation.component:diastolic.value[x].system
                    Definition

                    The identification of the system that provides the coded form of the unit.

                    ShortSystem that defines coded unit form
                    Control1..1
                    This element is affected by the following invariants: qty-3
                    Typeuri
                    Is Modifierfalse
                    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                    Must Supporttrue
                    Summarytrue
                    Requirements

                    Need to know the system that defines the coded form of the unit.

                    Fixed Valuehttp://unitsofmeasure.org
                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    180. Observation.component:diastolic.value[x].code
                    Definition

                    A computer processable form of the unit in some unit representation system.

                    ShortCoded form of the unit
                    Comments

                    The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                    Control1..1
                    Typecode
                    Is Modifierfalse
                    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                    Must Supporttrue
                    Summarytrue
                    Requirements

                    Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                    Fixed Valuemm[Hg]
                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    182. Observation.component:diastolic.dataAbsentReason
                    Definition

                    Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                    ShortWhy the component result is missing
                    Comments

                    "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                    The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                    Control0..1
                    This element is affected by the following invariants: obs-6, vs-3
                    BindingUnless not suitable, these codes SHALL be taken from DataAbsentReason
                    (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

                    Codes specifying why the result (Observation.value[x]) is missing.

                    TypeCodeableConcept
                    Is Modifierfalse
                    Must Supporttrue
                    Summaryfalse
                    Requirements

                    For many results it is necessary to handle exceptional values in measurements.

                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    184. Observation.component:diastolic.interpretation
                    Definition

                    A categorical assessment of an observation value. For example, high, low, normal.

                    ShortHigh, low, normal, etc.
                    Comments

                    Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                    Control0..*
                    BindingUnless not suitable, these codes SHALL be taken from ObservationInterpretationCodes
                    (extensible to http://hl7.org/fhir/ValueSet/observation-interpretation)

                    Codes identifying interpretations of observations.

                    TypeCodeableConcept
                    Is Modifierfalse
                    Summaryfalse
                    Requirements

                    For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                    Alternate NamesAbnormal Flag
                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    186. Observation.component:diastolic.referenceRange
                    Definition

                    Guidance on how to interpret the value by comparison to a normal or recommended range.

                    ShortProvides guide for interpretation of component result
                    Comments

                    Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                    Control0..*
                    TypeSee ttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                    Is Modifierfalse
                    Summaryfalse
                    Requirements

                    Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))