This page is part of the US Core (v4.1.0: STU5 Ballot 1) based on FHIR R4. The current version which supercedes this version is 5.0.1. For a full list of available versions, see the Directory of published versions
{
"resourceType" : "Observation",
"id" : "satO2-fiO2",
"meta" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/instance-name",
"valueString" : "Observation SatO2 FiO2 Example"
},
{
"url" : "http://hl7.org/fhir/StructureDefinition/instance-description",
"valueMarkdown" : "This is a observation satO2 fiO2 example for the *US Core Pulse Oximetry Profile* representing a spO2 value with a for a patient on 6 l/min of O2 suppplemental oxygen."
}
],
"profile" : [
"http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource \"satO2-fiO2\" </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-us-core-pulse-oximetry.html\">US Core Pulse Oximetry Profile</a></p></div><p><b>identifier</b>: id: o1223435-10</p><p><b>status</b>: final</p><p><b>category</b>: Vital Signs <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.0.0/CodeSystem-observation-category.html\">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Oxygen saturation in Arterial blood <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#2708-6; <a href=\"https://loinc.org/\">LOINC</a>#59408-5 \"Oxygen saturation in Arterial blood by Pulse oximetry\"; <a href=\"http://terminology.hl7.org/3.0.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#150456 \"MDC_PULS_OXIM_SAT_O2\")</span></p><p><b>subject</b>: <a href=\"Patient-example.html\">Patient/example</a> \" SHAW\"</p><p><b>effective</b>: 2014-12-05T09:30:10+01:00</p><p><b>value</b>: 95 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code % = '%')</span></p><p><b>interpretation</b>: Normal (applies to non-numeric results) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.0.0/CodeSystem-v3-ObservationInterpretation.html\">ObservationInterpretation</a>#N \"Normal\")</span></p><p><b>device</b>: <span>: Acme Pulse Oximeter 2000</span></p><h3>ReferenceRanges</h3><table class=\"grid\"><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>90 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code % = '%')</span></td><td>99 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code % = '%')</span></td></tr></table><h3>Components</h3><table class=\"grid\"><tr><td>-</td><td><b>Code</b></td><td><b>Value[x]</b></td></tr><tr><td>*</td><td>Inhaled oxygen flow rate <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#3151-8)</span></td><td>6 liters/min<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code L/min = 'L/min')</span></td></tr></table></div>"
},
"identifier" : [
{
"system" : "http://goodcare.org/observation/id",
"value" : "o1223435-10"
}
],
"status" : "final",
"category" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/observation-category",
"code" : "vital-signs",
"display" : "Vital Signs"
}
],
"text" : "Vital Signs"
}
],
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "2708-6",
"display" : "Oxygen saturation in Arterial blood"
},
{
"system" : "http://loinc.org",
"code" : "59408-5",
"display" : "Oxygen saturation in Arterial blood by Pulse oximetry"
},
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "150456",
"display" : "MDC_PULS_OXIM_SAT_O2"
}
]
},
"subject" : {
"reference" : "Patient/example"
},
"effectiveDateTime" : "2014-12-05T09:30:10+01:00",
"valueQuantity" : {
"value" : 95,
"unit" : "%",
"system" : "http://unitsofmeasure.org",
"code" : "%"
},
"interpretation" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
"code" : "N",
"display" : "Normal"
}
],
"text" : "Normal (applies to non-numeric results)"
}
],
"device" : {
"display" : "Acme Pulse Oximeter 2000"
},
"referenceRange" : [
{
"low" : {
"value" : 90,
"unit" : "%",
"system" : "http://unitsofmeasure.org",
"code" : "%"
},
"high" : {
"value" : 99,
"unit" : "%",
"system" : "http://unitsofmeasure.org",
"code" : "%"
}
}
],
"component" : [
{
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "3151-8",
"display" : "Inhaled oxygen flow rate"
}
],
"text" : "Inhaled oxygen flow rate"
},
"valueQuantity" : {
"value" : 6,
"unit" : "liters/min",
"system" : "http://unitsofmeasure.org",
"code" : "L/min"
}
}
]
}