Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry vs http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-temperature

Left:US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry)
Right:US Core Body Temperature Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-temperature)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry' vs 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-temperature'
ErrorStructureDefinition.versionValues for version differ: '3.1.1' vs '3.2.0'
InformationStructureDefinition.nameValues for name differ: 'USCorePulseOximetryProfile' vs 'USCoreBodyTemperatureProfile'
InformationStructureDefinition.titleValues for title differ: 'US Core Pulse Oximetry Profile' vs 'US Core Body Temperature Profile'
InformationStructureDefinition.dateValues for date differ: '2020-06-29' vs '2020-11-17'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 US Realm Steering Committee' vs 'HL7 International - US Realm Steering Committee'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/oxygensat' vs 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs'
WarningObservationElements differ in short: 'FHIR Oxygen Saturation Profile' 'US Core Body Temperature Profile'
WarningObservationElements differ in definition: 'This profile defines how to represent pulse oximetry and inspired oxygen concentration based on the FHIR Core Vitals Profile. INSPIRED OXYGEN CONCENTRATION observations in FHIR using a standard LOINC code and UCUM units of measure.' 'Defines constraints on Observation to represent body temperature observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.'
WarningObservation.codeElements differ in short: 'Oxygen Saturation by Pulse Oximetry' 'Body Temperature'
WarningObservation.codeElements differ in definition: 'Oxygen Saturation.' 'Coded Responses from C-CDA Vital Sign Results.'
WarningObservation.codeElements differ in comments: 'The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood -).' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
WarningObservation.codeElements differ in description: 'This identifies the vital sign result type.' 'The vital sign codes from the base FHIR and US Core Vital Signs.'
WarningObservation.codeElements differ in description: 'This identifies the vital sign result type.' 'The vital sign codes from the base FHIR and US Core Vital Signs.'
ErrorObservation.code.codingElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.value[x]Elements differ in short: 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' 'Vital Signs Value'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' 'Vital Signs value are typically recorded using the Quantity data type.'
WarningObservation.componentElements differ in short: 'Used when reporting systolic and diastolic blood pressure.' 'Component observations'
WarningObservation.componentElements differ in definition: 'Used when reporting systolic and diastolic blood pressure.' 'Used when reporting component observation such as systolic and diastolic blood pressure.'
WarningObservation.component.codeElements differ in description: 'This identifies the vital sign result type.' 'The vital sign codes from the base FHIR and US Core Vital Signs.'
WarningObservation.component.codeElements differ in description: 'This identifies the vital sign result type.' 'The vital sign codes from the base FHIR and US Core Vital Signs.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Value recorded with UCUM' 'Vital Sign Component Value'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Sign Value recorded with UCUM.' 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/oxygensathttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Added the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2020-06-292020-11-17
    • Values Differ
    .descriptionDefines constraints and extensions on the Observation resource for use in querying and retrieving inspired O2 by pulse oximetry observations.Defines constraints on Observation to represent body temperature observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.
    • Values Differ
    .experimentalfalse
      .fhirVersion4.0.1
        .jurisdiction
          ..jurisdiction[0]urn:iso:std:iso:3166#US
            .kindresource
              .nameUSCorePulseOximetryProfileUSCoreBodyTemperatureProfile
              • Values Differ
              .publisherHL7 US Realm Steering CommitteeHL7 International - US Realm Steering Committee
              • Values Differ
              .purpose
                .statusactive
                  .titleUS Core Pulse Oximetry ProfileUS Core Body Temperature Profile
                  • Values Differ
                  .typeObservation
                    .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetryhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-body-temperature
                    • Values Differ
                    .version3.1.13.2.0
                    • Values Differ

                    Structure

                    NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                    .. Observation II
                    • Elements differ in short: "FHIR Oxygen Saturation Profile" "US Core Body Temperature Profile"
                    • Elements differ in definition: "This profile defines how to represent pulse oximetry and inspired oxygen concentration based on the FHIR Core Vitals Profile. INSPIRED OXYGEN CONCENTRATION observations in FHIR using a standard LOINC code and UCUM units of measure." "Defines constraints on Observation to represent body temperature observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile."
                    ... id ΣΣ
                      ... meta ΣΣ
                        ... implicitRules ?!Σ?!Σ
                          ... language
                            ... text
                              ... contained
                                ... extension ExtensionExtension
                                  ... modifierExtension ?!?!
                                    ... identifier ΣΣ
                                      ... basedOn ΣΣ
                                        ... partOf ΣΣ
                                          ... status ?!SΣ?!SΣ
                                            ... category S(Slice Definition)S(Slice Definition)
                                              ... code SΣSΣ
                                              • Elements differ in short: "Oxygen Saturation by Pulse Oximetry" "Body Temperature"
                                              • Elements differ in definition: "Oxygen Saturation." "Coded Responses from C-CDA Vital Sign Results."
                                              • Elements differ in comments: "The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood -)." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                              • Elements differ in description: "This identifies the vital sign result type." "The vital sign codes from the base FHIR and US Core Vital Signs."
                                              • Elements differ in description: "This identifies the vital sign result type." "The vital sign codes from the base FHIR and US Core Vital Signs."
                                              .... id
                                                .... extension ExtensionExtension
                                                  .... coding SΣ(Slice Definition)Σ
                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                  .... text ΣΣ
                                                    ... subject SΣSΣ
                                                      ... focus ΣΣ
                                                        ... encounter ΣΣ
                                                          ... effective[x] SΣISΣI
                                                            ... issued ΣΣ
                                                              ... performer ΣΣ
                                                                ... value[x] SΣI(Slice Definition)SΣI(Slice Definition)
                                                                • Elements differ in short: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "Vital Signs Value"
                                                                • Elements differ in definition: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "Vital Signs value are typically recorded using the Quantity data type."
                                                                ... dataAbsentReason SISI
                                                                  ... interpretation
                                                                    ... note
                                                                      ... bodySite
                                                                        ... method
                                                                          ... specimen
                                                                            ... device
                                                                              ... referenceRange II
                                                                                .... id
                                                                                  .... extension ExtensionExtension
                                                                                    .... modifierExtension ?!Σ?!Σ
                                                                                      .... low II
                                                                                        .... high II
                                                                                          .... type
                                                                                            .... appliesTo
                                                                                              .... age
                                                                                                .... text
                                                                                                  ... hasMember ΣΣ
                                                                                                    ... derivedFrom ΣΣ
                                                                                                      ... component SΣI(Slice Definition)SΣI
                                                                                                      • Elements differ in short: "Used when reporting systolic and diastolic blood pressure." "Component observations"
                                                                                                      • Elements differ in definition: "Used when reporting systolic and diastolic blood pressure." "Used when reporting component observation such as systolic and diastolic blood pressure."
                                                                                                      .... id
                                                                                                        .... extension ExtensionExtension
                                                                                                          .... modifierExtension ?!Σ?!Σ
                                                                                                            .... code SΣSΣ
                                                                                                            • Elements differ in description: "This identifies the vital sign result type." "The vital sign codes from the base FHIR and US Core Vital Signs."
                                                                                                            • Elements differ in description: "This identifies the vital sign result type." "The vital sign codes from the base FHIR and US Core Vital Signs."
                                                                                                            .... value[x] SΣISΣI
                                                                                                            • Elements differ in short: "Vital Sign Value recorded with UCUM" "Vital Sign Component Value"
                                                                                                            • Elements differ in definition: "Vital Sign Value recorded with UCUM." "Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept."
                                                                                                            .... dataAbsentReason SISI
                                                                                                              .... interpretation
                                                                                                                .... referenceRange

                                                                                                                  doco Documentation for this format