Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/head-occipital-frontal-circumference-percentile' vs 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' |
Error | StructureDefinition.version | Values for version differ: '3.1.1' vs '3.2.0' |
Information | StructureDefinition.name | Values for name differ: 'UsCorePediatricHeadOccipitalFrontalCircumferencePercentileProfile' vs 'USCoreVitalSignsProfile' |
Information | StructureDefinition.title | Values for title differ: 'US Core Pediatric Head Occipital-frontal Circumference Percentile Profile' vs 'US Core Vital Signs Profile' |
Information | StructureDefinition.date | Values for date differ: '2020-07-01' vs '2020-11-17' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 US Realm Steering Committee' vs 'HL7 International - US Realm Steering Committee' |
Warning | Observation | Elements differ in short:
'FHIR Vital Signs Profile'
'US Core Vital Signs Profile' |
Warning | Observation | Elements differ in definition:
'This profile defines how to represent head occipital-frontal circumference percentile for patients from birth to 36 months of age in FHIR using a standard LOINC code and UCUM units of measure.'
'Defines constraints on the Observation resource to represent vital signs observation. This profile is used as the base definition for the other US Core Vital Signs Profiles and based on the FHIR VitalSigns Profile.' |
Warning | Observation.code | Elements differ in short:
'Head Occipital-frontal circumference Percentile'
'Coded Responses from C-CDA Vital Sign Results' |
Warning | Observation.code | Elements differ in comments:
'additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.'
'*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.' |
Warning | Observation.code | Elements differ in description:
'This identifies the vital sign result type.'
'The vital sign codes from the base FHIR and US Core Vital Signs.' |
Warning | Observation.code | Elements differ in description:
'This identifies the vital sign result type.'
'The vital sign codes from the base FHIR and US Core Vital Signs.' |
Warning | Observation.value[x] | Elements differ in short:
'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
'Vital Signs Value' |
Warning | Observation.value[x] | Elements differ in definition:
'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
'Vital Signs value are typically recorded using the Quantity data type.' |
Warning | Observation.component | Elements differ in short:
'Used when reporting systolic and diastolic blood pressure.'
'Component observations' |
Warning | Observation.component | Elements differ in definition:
'Used when reporting systolic and diastolic blood pressure.'
'Used when reporting component observation such as systolic and diastolic blood pressure.' |
Warning | Observation.component.code | Elements differ in description:
'This identifies the vital sign result type.'
'The vital sign codes from the base FHIR and US Core Vital Signs.' |
Warning | Observation.component.code | Elements differ in description:
'This identifies the vital sign result type.'
'The vital sign codes from the base FHIR and US Core Vital Signs.' |
Warning | Observation.component.value[x] | Elements differ in short:
'Vital Sign Value recorded with UCUM'
'Vital Sign Component Value' |
Warning | Observation.component.value[x] | Elements differ in definition:
'Vital Sign Value recorded with UCUM.'
'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' |