This page is part of the CodeX™ Radiation Therapy (v1.0.0-ballot: STU 1 Ballot 1) based on FHIR R4. . For a full list of available versions, see the Directory of published versions
Definitions for the codexrt-radiotheraphy-treatment-device extension.
1. Extension | |
Definition | The device used for delivering the Radiotherapy. This can be a treatment machine or auxiliary device, for example a positioning device. Could be used for a LINAC (external beam) or an Afterloader (brachytherapy). The device is specified by its manufacturer and model number. |
Control | 0..* This element is affected by the following invariants: ele-1 |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (: extension.exists() != value.exists()) |
2. Extension.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
3. Extension.extension | |
Definition | An Extension |
Control | 2..* |
Type | Extension |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (: extension.exists() != value.exists()) |
Slicing | This element introduces a set of slices on Extension.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
|
4. Extension.extension:manufacturer | |
SliceName | manufacturer |
Definition | The manufacturer of a device used for delivering radiotherapy. |
Control | 1..1 |
Type | Extension(RadiotherapyTreatmentDeviceManufacturer) (Extension Type: string) |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (: extension.exists() != value.exists()) |
5. Extension.extension:model | |
SliceName | model |
Definition | The model number of a device used for delivering radiotherapy.. |
Control | 1..1 |
Type | Extension(RadiotherapyTreatmentDeviceModel) (Extension Type: string) |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (: extension.exists() != value.exists()) |
6. Extension.url | |
Definition | Source of the definition for the extension code - a logical name or a URL. |
Control | 1..1 |
Type | uri |
Comments | The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension. |
Fixed Value | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotheraphy-treatment-device |
7. Extension.value[x] | |
Definition | Value of extension - must be one of a constrained set of the data types (see Extensibility for a list). |
Control | 0..0 |
Type | Choice of: base64Binary, boolean, canonical, code, date, dateTime, decimal, id, instant, integer, markdown, oid, positiveInt, string, time, unsignedInt, uri, url, uuid, Address, Age, Annotation, Attachment, CodeableConcept, Coding, ContactPoint, Count, Distance, Duration, HumanName, Identifier, Money, Period, Quantity, Range, Ratio, Reference, SampledData, Signature, Timing, ContactDetail, Contributor, DataRequirement, Expression, ParameterDefinition, RelatedArtifact, TriggerDefinition, UsageContext, Dosage, Meta |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) |