Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/pediatric-weight-for-height vs http://hl7.org/fhir/us/bfdr/StructureDefinition/Observation-edit-flag-number-previous-cesareans

Left:US Core Pediatric Weight for Height Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/pediatric-weight-for-height)
Right:Observation - Edit Flag Number of Previous Cesareans (http://hl7.org/fhir/us/bfdr/StructureDefinition/Observation-edit-flag-number-previous-cesareans)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/pediatric-weight-for-height' vs 'http://hl7.org/fhir/us/bfdr/StructureDefinition/Observation-edit-flag-number-previous-cesareans'
ErrorStructureDefinition.versionValues for version differ: '3.1.1' vs '0.1.0'
InformationStructureDefinition.nameValues for name differ: 'USCorePediatricWeightForHeightObservationProfile' vs 'ObservationEditFlagNumberPreviousCesareans'
InformationStructureDefinition.titleValues for title differ: 'US Core Pediatric Weight for Height Observation Profile' vs 'Observation - Edit Flag Number of Previous Cesareans'
InformationStructureDefinition.dateValues for date differ: '2020-06-27' vs '2020-12-16T19:12:11+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 US Realm Steering Committee' vs 'HL7 International - Public Health Work Group'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/vitalsigns' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'FHIR Vital Signs Profile' 'Measurements and simple assertions'
WarningObservationElements differ in definition: 'This profile defines how to represent Weight-for-length per age and gender observations in FHIR using a standard LOINC code and UCUM units of measure.' 'Measurements and simple assertions made about a patient, device or other subject.'
ErrorObservation.statusElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Weight-for-length per age and gender' 'Number of Previous Cesareans edit flag'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.codeElements differ in binding.description: 'This identifies the vital sign result type.' 'Codes identifying names of simple observations.'
ErrorObservation.subjectElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
ErrorObservation.effective[x]Elements differ in definition for mustSupport: 'true' 'false'
WarningObservation.value[x]Elements differ in short: 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' 'Number of Previous Cesareans Edit Flags (NCHS)'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' 'Related resource that belongs to the Observation group'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
WarningObservation.componentElements differ in short: 'Used when reporting systolic and diastolic blood pressure.' 'Component results'
WarningObservation.componentElements differ in definition: 'Used when reporting systolic and diastolic blood pressure.' 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
ErrorObservation.componentElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.component.codeElements differ in binding.description: 'This identifies the vital sign result type.' 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Value recorded with UCUM' 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Sign Value recorded with UCUM.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.component.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/vitalsignshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyright
      .date2020-06-272020-12-16T19:12:11+00:00
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for use in querying and retrieving pediatric Weight-for-length per age and gender observations.This profile indicates whether the original number of previous cesareans data provided passed validation checks. These validation checks are done at the jurisdiction prior to sending to the National Statistical Agency and are based on the item specific edit criteria specified in the Birth Edit Specifications for the 2003 Proposed Revision of the U.S. Standard Certificate of Birth and the Fetal Death Edit Specifications for the 2003 Revision of the U.S. Standard Report of Fetal Death.
      • Values Differ
      .experimentalfalse
        .fhirVersion4.0.1
          .jurisdiction
            ..jurisdiction[0]urn:iso:std:iso:3166#US
              .kindresource
                .nameUSCorePediatricWeightForHeightObservationProfileObservationEditFlagNumberPreviousCesareans
                • Values Differ
                .publisherHL7 US Realm Steering CommitteeHL7 International - Public Health Work Group
                • Values Differ
                .purpose
                  .statusactive
                    .titleUS Core Pediatric Weight for Height Observation ProfileObservation - Edit Flag Number of Previous Cesareans
                    • Values Differ
                    .typeObservation
                      .urlhttp://hl7.org/fhir/us/core/StructureDefinition/pediatric-weight-for-heighthttp://hl7.org/fhir/us/bfdr/StructureDefinition/Observation-edit-flag-number-previous-cesareans
                      • Values Differ
                      .version3.1.10.1.0
                      • Values Differ

                      Structure

                      NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                      .. Observation II
                      • Elements differ in short: "FHIR Vital Signs Profile" "Measurements and simple assertions"
                      • Elements differ in definition: "This profile defines how to represent Weight-for-length per age and gender observations in FHIR using a standard LOINC code and UCUM units of measure." "Measurements and simple assertions made about a patient, device or other subject."
                      ... id ΣΣ
                        ... meta ΣΣ
                          ... implicitRules ?!Σ?!Σ
                            ... language
                              ... text
                                ... contained
                                  ... extension ExtensionExtension
                                    ... modifierExtension ?!?!
                                      ... identifier ΣΣ
                                        ... basedOn ΣΣ
                                          ... partOf ΣΣ
                                            ... status ?!SΣ?!Σ
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... category S(Slice Definition)
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... code SΣSΣ
                                            • Elements differ in short: "Weight-for-length per age and gender" "Number of Previous Cesareans edit flag"
                                            • Elements differ in definition: "Coded Responses from C-CDA Vital Sign Results." "Describes what was observed. Sometimes this is called the observation "name"."
                                            • Elements differ in comments: "additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                            • Elements differ in requirements: "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)." "Knowing what kind of observation is being made is essential to understanding the observation."
                                            • Elements differ in binding.description: "This identifies the vital sign result type." "Codes identifying names of simple observations."
                                            ... subject SΣΣ
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... focus ΣΣ
                                              ... encounter ΣΣ
                                                ... effective[x] SΣIΣ
                                                • Elements differ in short: "Often just a dateTime for Vital Signs" "Clinically relevant time/time-period for observation"
                                                • Elements differ in definition: "Often just a dateTime for Vital Signs." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                                • Elements differ in definition for mustSupport: "true" "false"
                                                ... issued ΣΣ
                                                  ... performer ΣΣ
                                                    ... value[x] SΣI(Slice Definition)SΣI
                                                    • Elements differ in short: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "Number of Previous Cesareans Edit Flags (NCHS)"
                                                    • Elements differ in definition: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "The information determined as a result of making the observation, if the information has a simple value."
                                                    • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                    ... dataAbsentReason SII
                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                    ... interpretation
                                                      ... note
                                                        ... bodySite
                                                          ... method
                                                            ... specimen
                                                              ... device
                                                                ... referenceRange II
                                                                  .... id
                                                                    .... extension ExtensionExtension
                                                                      .... modifierExtension ?!Σ?!Σ
                                                                        .... low II
                                                                          .... high II
                                                                            .... type
                                                                              .... appliesTo
                                                                                .... age
                                                                                  .... text
                                                                                    ... hasMember ΣΣ
                                                                                    • Elements differ in short: "Used when reporting vital signs panel components" "Related resource that belongs to the Observation group"
                                                                                    • Elements differ in definition: "Used when reporting vital signs panel components." "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group."
                                                                                    • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                                    ... derivedFrom ΣΣ
                                                                                      ... component SΣIΣ
                                                                                      • Elements differ in short: "Used when reporting systolic and diastolic blood pressure." "Component results"
                                                                                      • Elements differ in definition: "Used when reporting systolic and diastolic blood pressure." "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations."
                                                                                      • Elements differ in definition for mustSupport: "true" "false"
                                                                                      .... id
                                                                                        .... extension ExtensionExtension
                                                                                          .... modifierExtension ?!Σ?!Σ
                                                                                            .... code SΣΣ
                                                                                            • Elements differ in definition for mustSupport: "true" "false"
                                                                                            • Elements differ in binding.description: "This identifies the vital sign result type." "Codes identifying names of simple observations."
                                                                                            .... value[x] SΣIΣ
                                                                                            • Elements differ in short: "Vital Sign Value recorded with UCUM" "Actual component result"
                                                                                            • Elements differ in definition: "Vital Sign Value recorded with UCUM." "The information determined as a result of making the observation, if the information has a simple value."
                                                                                            • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                                                            • Elements differ in definition for mustSupport: "true" "false"
                                                                                            .... dataAbsentReason SII
                                                                                            • Elements differ in definition for mustSupport: "true" "false"
                                                                                            .... interpretation
                                                                                              .... referenceRange

                                                                                                doco Documentation for this format