FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationdispense0316.xml

Pharmacy Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Patient, Practitioner

Raw XML (canonical form)

Jump past Narrative

Dispense for Insulin (Lantus) (NDC code) - in-progress with SC dosage (id = "meddisp0316")

<MedicationDispense xmlns="http://hl7.org/fhir">
    <id value="meddisp0316"/> 
    <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : meddisp0316</p> <p> <b> status</b> : in-progress</p> <p> <b> medication</b> : Lantus 100 unit/ml injectable solution <span> (Details : {RxNorm code '285018' = '285018', given as 'Lantus 100 unit/ml injectable solution'})</span> </p> <p> <b> subject</b> : <a> Donald Duck </a> </p> <h3> Performers</h3> <table> <tr> <td> -</td> <td> <b> Actor</b> </td> <td> <b> OnBehalfOf</b> </td> </tr> <tr> <td> *</td> <td> <a> Practitioner/f006</a> </td> <td> <a> Organization/2.16.840.1.113883.19.5</a> </td> </tr> </table> <p> <b> authorizingPrescription</b> : <a> MedicationRequest/medrx0320</a> </p> <p> <b> type</b> : Refill - Part Fill <span> (Details : {http://hl7.org/fhir/v3/ActCode code 'RFP' = 'Refill - Part Fill', given as
           'Refill - Part Fill'})</span> </p> <p> <b> quantity</b> : 10 ml<span>  (Details: UCUM code ml = 'ml')</span> </p> <p> <b> daysSupply</b> : 30 Day<span>  (Details: UCUM code d = 'd')</span> </p> <p> <b> whenPrepared</b> : 25/06/2015 7:13:00 AM</p> <p> <b> dosageInstruction</b> : </p> </div> </text> <status value="in-progress"/> 
    <medicationCodeableConcept> 
        <coding> 
            <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> 
            <code value="285018"/> 
            <display value="Lantus 100 unit/ml injectable solution"/> 
        </coding> 
    </medicationCodeableConcept> 
    <subject> 
        <reference value="Patient/pat1"/> 
        <display value="Donald Duck "/>  
    </subject> 
    <performer> 
        <actor> 
            <reference value="Practitioner/f006"/> 
        </actor> 
        <onBehalfOf> 
            <reference value="Organization/2.16.840.1.113883.19.5"/> 
        </onBehalfOf> 
    </performer> 
    <authorizingPrescription> 
        <reference value="MedicationRequest/medrx0320"/> 
    </authorizingPrescription> 
    <type> 
        <coding> 
            <system value="http://hl7.org/fhir/v3/ActCode"/> 
            <code value="RFP"/> 
            <display value="Refill - Part Fill"/> 
        </coding> 
    </type> 
    <quantity> 
        <value value="10"/> 
        <system value="http://unitsofmeasure.org"/> 
        <code value="ml"/> 
    </quantity> 
    <daysSupply> 
        <value value="30"/> 
        <unit value="Day"/> 
        <system value="http://unitsofmeasure.org"/> 
        <code value="d"/> 
    </daysSupply> 
    <whenPrepared value="2015-06-25T07:13:00+05:00"/> 
    <dosageInstruction> 
        <sequence value="1"/> 
        <text value="20 Units SC three times daily"/> 
        <timing> 
            <repeat> 
                <frequency value="3"/> 
                <period value="1"/> 
                <periodUnit value="d"/> 
            </repeat> 
        </timing> 
        <route> 
            <coding> 
                <system value="http://snomed.info/sct"/> 
                <code value="263887005"/> 
                <display value="Subcutaneous (qualifier value)"/> 
            </coding> 
        </route> 
        <doseQuantity> 
            <value value="20"/> 
            <unit value="U"/> 
            <system value="http://unitsofmeasure.org"/> 
            <code value="U"/> 
        </doseQuantity> 
    </dosageInstruction>  
</MedicationDispense> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.