This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Patient, Practitioner |
Dispense for Lorazepam (Rx norm code) - completed with rate range
{ "resourceType": "MedicationDispense", "id": "meddisp0314", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: meddisp0314</p><p><b>contained</b>: </p><p><b>status</b>: completed</p><p><b>medication</b>: id: med0313; Lorazepam 2mg/ml Injectable Solution (Ativan) <span>(Details : {RxNorm code '206819' = '206819', given as 'Lorazepam 2mg/ml Injectable Solution (Ativan)'})</span>; isBrand; Injection solution (qualifier value) <span>(Details : {SNOMED CT code '385219001' = 'Injection solution', given as 'Injection solution (qualifier value)'})</span></p><p><b>subject</b>: <a>Donald Duck </a></p><h3>Performers</h3><table><tr><td>-</td><td><b>Actor</b></td><td><b>OnBehalfOf</b></td></tr><tr><td>*</td><td><a>Practitioner/f006</a></td><td><a>Organization/2.16.840.1.113883.19.5</a></td></tr></table><p><b>authorizingPrescription</b>: <a>MedicationRequest/medrx0315</a></p><p><b>type</b>: Trial Fill <span>(Details : {http://hl7.org/fhir/v3/ActCode code 'TF' = 'Trial Fill', given as 'Trial Fill'})</span></p><p><b>quantity</b>: 1 415818005<span> (Details: SNOMED CT code 415818005 = '415818005')</span></p><p><b>daysSupply</b>: 1 Day<span> (Details: UCUM code d = 'd')</span></p><p><b>whenPrepared</b>: 25/06/2015 7:13:00 AM</p><p><b>whenHandedOver</b>: 26/06/2015 7:13:00 AM</p><p><b>dosageInstruction</b>: </p></div>" }, "contained": [ { "resourceType": "Medication", "id": "med0313", "code": { "coding": [ { "system": "http://www.nlm.nih.gov/research/umls/rxnorm", "code": "206819", "display": "Lorazepam 2mg/ml Injectable Solution (Ativan)" } ] }, "isBrand": true, "form": { "coding": [ { "system": "http://snomed.info/sct", "code": "385219001", "display": "Injection solution (qualifier value)" } ] }, "ingredient": [ { "itemCodeableConcept": { "coding": [ { "system": "http://snomed.info/sct", "code": "387106007", "display": "Lorazepam (substance)" } ] }, "amount": { "numerator": { "value": 2, "system": "http://unitsofmeasure.org", "code": "mg" }, "denominator": { "value": 1, "system": "http://unitsofmeasure.org", "code": "mL" } } } ] } ], "status": "completed", "medicationReference": { "reference": "#med0313" }, "subject": { "reference": "Patient/pat1", "display": "Donald Duck " }, "performer": [ { "actor": { "reference": "Practitioner/f006" }, "onBehalfOf": { "reference": "Organization/2.16.840.1.113883.19.5" } } ], "authorizingPrescription": [ { "reference": "MedicationRequest/medrx0315" } ], "type": { "coding": [ { "system": "http://hl7.org/fhir/v3/ActCode", "code": "TF", "display": "Trial Fill" } ] }, "quantity": { "value": 1, "system": "http://snomed.info/sct", "code": "415818005" }, "daysSupply": { "value": 1, "unit": "Day", "system": "http://unitsofmeasure.org", "code": "d" }, "whenPrepared": "2015-06-25T07:13:00+05:00", "whenHandedOver": "2015-06-26T07:13:00+05:00", "dosageInstruction": [ { "sequence": 1, "text": "7mg IV over 2-5 minutes every 15 minutes as needed", "timing": { "repeat": { "frequency": 1, "period": 15, "periodUnit": "min" } }, "asNeededBoolean": true, "route": { "coding": [ { "system": "http://snomed.info/sct", "code": "255560000", "display": "Intravenous" } ] }, "method": { "coding": [ { "system": "http://snomed.info/sct", "code": "420620005", "display": "Push - dosing instruction imperative (qualifier value)" } ] }, "doseQuantity": { "value": 7, "unit": "mg", "system": "http://unitsofmeasure.org", "code": "mg" }, "rateRange": { "low": { "value": 2, "unit": "min", "system": "http://unitsofmeasure.org", "code": "min" }, "high": { "value": 5, "unit": "min", "system": "http://unitsofmeasure.org", "code": "min" } } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.