Publish-box (todo)
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
Example definition of venous blood specimen.
{ "resourceType" : "SpecimenDefinition", "id" : "7", "text" : { "status" : "generated", "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: SpecimenDefinition</b><a name=\"7\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource SpecimenDefinition "7" </p></div><p><b>url</b>: <code>http://example-lab.com/specdef/123455</code></p><p><b>identifier</b>: id:\u00a0123455</p><p><b>title</b>: Venous blood specimen</p><p><b>status</b>: active</p><p><b>experimental</b>: true</p><p><b>typeCollected</b>: Venous blood specimen (specimen) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#122555007)</span></p><p><b>patientPreparation</b>: no strict fasting <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><blockquote><p><b>typeTested</b></p><p><b>isDerived</b>: true</p><p><b>type</b>: Serum specimen (specimen) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#119364003)</span></p><p><b>preference</b>: preferred</p><h3>Containers</h3><table class=\"grid\"><tr><td>-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td>glass <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></td><td>Evacuated blood collection tube with thrombin and clot activator and gel separator <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#702281005)</span></td><td>yellow cap <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (CodeSystem-container-cap.html#yellow)</span></td><td>2 ml<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mL = 'mL')</span></td></tr></table><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: room temperature <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ([not stated]#room)</span></p><p><b>temperatureRange</b>: 15-25 °C</p><h3>MaxDurations</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>12</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table></blockquote></blockquote></div>" }, "url" : "http://example-lab.com/specdef/123455", "identifier" : { "value" : "123455" }, "title" : "Venous blood specimen", "status" : "active", "experimental" : true, "typeCollected" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "122555007" }], "text" : "Venous blood specimen (specimen)" }, "patientPreparation" : [{ "text" : "no strict fasting" }], "typeTested" : [{ "isDerived" : true, "type" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "119364003" }], "text" : "Serum specimen (specimen)" }, "preference" : "preferred", "container" : { "material" : { "text" : "glass" }, "type" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "702281005", "display" : "Evacuated blood collection tube with thrombin and clot activator and gel separator" }] }, "cap" : { "coding" : [{ "system" : "http://terminology.hl7.org/5.1.0/CodeSystem-container-cap.html", "code" : "yellow", "display" : "yellow cap" }] }, "minimumVolumeQuantity" : { "value" : 2, "unit" : "ml", "system" : "http://unitsofmeasure.org", "code" : "mL" } }, "handling" : [{ "temperatureQualifier" : { "coding" : [{ "code" : "room", "display" : "room temperature" }] }, "temperatureRange" : { "low" : { "value" : 15, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" }, "high" : { "value" : 25, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" } }, "maxDuration" : { "value" : 12, "system" : "http://unitsofmeasure.org", "code" : "h" } }] }] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:26+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4 |
Compare to R4B |
|
Propose a change