This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version in it's permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Example MedicationAdministration/medadmin0303 (XML)
Raw XML (canonical form + also see XML Format Specification)
Jump past Narrative
Intravenous Antibiotic with a Dosage Rate - Piperacillin (id = "medadmin0303")
<?xml version="1.0" encoding="UTF-8"?>
<MedicationAdministration xmlns="http://hl7.org/fhir">
<id value="medadmin0303"/>
<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: MedicationAdministration</b> <a name="medadmin0303"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource MedicationAdministration "medadmin0303" </p> </div> <p> <b> status</b> : entered-in-error</p> <h3> Medications</h3> <table class="grid"><tr> <td> -</td> <td> <b> Reference</b> </td> </tr> <tr> <td> *</td> <td> <a name="med0303"> </a> <blockquote> <p/> <p> <a name="med0303"> </a> </p> <p> <b> code</b> : Zosyn (piperacillin/tazobactam) 4.5gm injection <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-ndc.html">National drug codes</a> #0206-8862-02)</span> </p> </blockquote> </td> </tr> </table> <p> <b> subject</b> : <a href="patient-example-a.html">Patient/pat1: Donald Duck</a> "Donald DUCK"</p> <p> <b> encounter</b> : <a href="encounter-example-f001-heart.html">Encounter/f001: encounter who leads to this prescription</a> </p> <p> <b> occurence</b> : 2015-01-15T04:30:00+01:00 --> 2015-01-15T14:30:00+01:00</p> <blockquote> <p> <b> performer</b> </p> <h3> Actors</h3> <table class="grid"><tr> <td> -</td> <td> <b> Reference</b> </td> </tr> <tr> <td> *</td> <td> <a href="practitioner-example-f007-sh.html">Practitioner/f007: Patrick Pump</a> "Simone HEPS"</td> </tr> </table> </blockquote> <p> <b> request</b> : <a href="medicationrequest0319.html">MedicationRequest/medrx0319</a> </p> <h3> Dosages</h3> <table class="grid"><tr> <td> -</td> <td> <b> Text</b> </td> <td> <b> Route</b> </td> <td> <b> Dose</b> </td> <td> <b> Rate[x]</b> </td> </tr> <tr> <td> *</td> <td> 4.5 grams in D5W 250 ml. IV every 6 hours. Infuse over 30 min at 8L/min </td> <td> Intravenous route (qualifier value) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #47625008)</span> </td> <td> 4.5 g<span style="background: LightGoldenRodYellow"> (Details: UCUM code g = 'g')</span> </td> <td> 8 ml<span style="background: LightGoldenRodYellow"> (Details: UCUM code ml = 'ml')</span> /1 min<span style="background: LightGoldenRodYellow"> (Details: UCUM code min = 'min')</span> </td> </tr> </table> </div> </text> <contained>
<Medication>
<id value="med0303"/>
<code>
<coding>
<system value="http://hl7.org/fhir/sid/ndc"/>
<code value="0206-8862-02"/>
<display value="Zosyn (piperacillin/tazobactam) 4.5gm injection"/>
</coding>
</code>
</Medication>
</contained>
<status value="entered-in-error"/>
<medication>
<reference>
<reference value="#med0303"/> </reference>
</medication>
<subject>
<reference value="Patient/pat1"/>
<display value="Donald Duck"/>
</subject>
<encounter>
<reference value="Encounter/f001"/>
<display value="encounter who leads to this prescription"/>
</encounter>
<occurencePeriod>
<start value="2015-01-15T04:30:00+01:00"/>
<end value="2015-01-15T14:30:00+01:00"/>
</occurencePeriod>
<performer>
<actor>
<reference>
<reference value="Practitioner/f007"/>
<display value="Patrick Pump"/>
</reference>
</actor>
</performer>
<request>
<reference value="MedicationRequest/medrx0319"/>
</request>
<dosage>
<text value="4.5 grams in D5W 250 ml. IV every 6 hours. Infuse over 30 min at 8L/min "/>
<route>
<coding>
<system value="http://snomed.info/sct"/>
<code value="47625008"/>
<display value="Intravenous route (qualifier value)"/>
</coding>
</route>
<dose>
<value value="4.5"/>
<unit value="g"/>
<system value="http://unitsofmeasure.org"/>
<code value="g"/>
</dose>
<rateRatio>
<numerator>
<value value="8"/>
<system value="http://unitsofmeasure.org"/>
<code value="ml"/>
</numerator>
<denominator>
<value value="1"/>
<system value="http://unitsofmeasure.org"/>
<code value="min"/>
</denominator>
</rateRatio>
</dosage>
</MedicationAdministration>
Usage note: every effort has been made to ensure that the
examples are correct and useful, but they are not a normative part
of the specification.