Release 5

This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version in it's permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Example DiagnosticReport/f202 (JSON)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner

Raw JSON (canonical form + also see JSON Format Specification)

Real-world patient example

{
  "resourceType" : "Bundle",
  "id" : "f202",
  "type" : "collection",
  "entry" : [{
    "fullUrl" : "https://example.com/base/DiagnosticReport/f202",
    "resource" : {
      "resourceType" : "DiagnosticReport",
      "id" : "f202",
      "text" : {
        "status" : "generated",
        "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2><span title=\"Codes: {http://snomed.info/sct 104177005}\">Blood culture for bacteria, including anaerobic screen</span> (<span title=\"Codes: {http://snomed.info/sct 15220000}, {http://terminology.hl7.org/CodeSystem/v2-0074 LAB}\">Laboratory test</span>) </h2><table class=\"grid\"><tr><td>Subject</td><td><b>Roel(OFFICIAL)</b> male, DoB: 1960-03-13 ( BSN:\u00a0123456789\u00a0(use:\u00a0OFFICIAL))</td></tr><tr><td>Reported</td><td>2013-03-11T10:28:00+01:00</td></tr></table><p><b>Report Details</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>Value</b></td><td><b>Flags</b></td><td><b>Reported</b></td></tr><tr><td><a href=\"observation-example-f206-staphylococcus.html\"><span title=\"Codes: {http://acmelabs.org 104177}, {http://loinc.org 600-7}\">Blood culture</span></a></td><td><span title=\"Codes: {http://snomed.info/sct 3092008}\">Staphylococcus aureus</span></td><td><span title=\"Codes: {http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation POS}\">Positive</span></td><td/></tr></table><div><p>Blood culture tested positive on staphylococcus aureus</p>\n</div><p><b>Coded Conclusions :</b></p><ul><li><span title=\"Codes: {http://snomed.info/sct 428763004}\">Bacteremia due to staphylococcus</span></li></ul></div>"
      },
      "basedOn" : [{
        "reference" : "ServiceRequest/req"
      }],
      "status" : "final",
      "category" : [{
        "coding" : [{
          "system" : "http://snomed.info/sct",
          "code" : "15220000",
          "display" : "Laboratory test"
        },
        {
          "system" : "http://terminology.hl7.org/CodeSystem/v2-0074",
          "code" : "LAB"
        }]
      }],
      "code" : {
        "coding" : [{
          "system" : "http://snomed.info/sct",
          "code" : "104177005",
          "display" : "Blood culture for bacteria, including anaerobic screen"
        }]
      },
      "subject" : {
        "reference" : "Patient/f201",
        "display" : "Roel"
      },
      "issued" : "2013-03-11T10:28:00+01:00",
      "performer" : [{
        "reference" : "Organization/f201",
        "display" : "AUMC"
      }],
      "result" : [{
        "reference" : "Observation/f206",
        "display" : "Results for staphylococcus analysis on Roel's blood culture"
      }],
      "conclusion" : "Blood culture tested positive on staphylococcus aureus",
      "conclusionCode" : [{
        "coding" : [{
          "system" : "http://snomed.info/sct",
          "code" : "428763004",
          "display" : "Bacteremia due to staphylococcus"
        }]
      }]
    }
  },
  {
    "fullUrl" : "https://example.com/base/ServiceRequest/req",
    "resource" : {
      "resourceType" : "ServiceRequest",
      "id" : "req",
      "text" : {
        "status" : "generated",
        "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: ServiceRequest</b><a name=\"req\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource ServiceRequest &quot;req&quot; </p></div><p><b>status</b>: active</p><p><b>intent</b>: original-order</p><h3>Codes</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td></tr><tr><td>*</td><td>Blood culture for bacteria, including anaerobic screen <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#104177005)</span></td></tr></table><p><b>subject</b>: <a href=\"patient-example-f201-roel.html\">Patient/f201: Roel</a> &quot;Roel&quot;</p><p><b>encounter</b>: <a href=\"encounter-example-f203-20130311.html\">Encounter/f203: Roel's encounter on March elevanth 2013</a></p><p><b>requester</b>: <a href=\"practitioner-example-f201-ab.html\">Practitioner/f201: Dokter Bronsig</a> &quot;Dokter Bronsig&quot;</p></div>"
      },
      "status" : "active",
      "intent" : "original-order",
      "code" : {
        "concept" : {
          "coding" : [{
            "system" : "http://snomed.info/sct",
            "code" : "104177005",
            "display" : "Blood culture for bacteria, including anaerobic screen"
          }]
        }
      },
      "subject" : {
        "reference" : "Patient/f201",
        "display" : "Roel"
      },
      "encounter" : {
        "reference" : "Encounter/f203",
        "display" : "Roel's encounter on March elevanth 2013"
      },
      "requester" : {
        "reference" : "Practitioner/f201",
        "display" : "Dokter Bronsig"
      }
    }
  }]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.