Release 5

This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version in it's permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Example Condition/f201 (JSON)

Patient Care Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Encounter, Patient, Practitioner, RelatedPerson

Raw JSON (canonical form + also see JSON Format Specification)

Real-word condition example (fever)

{
  "resourceType" : "Condition",
  "id" : "f201",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Condition</b><a name=\"f201\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Condition &quot;f201&quot; </p></div><p><b>identifier</b>: id:\u00a012345</p><p><b>clinicalStatus</b>: Resolved <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-condition-clinical.html\">Condition Clinical Status Codes</a>#resolved)</span></p><p><b>verificationStatus</b>: Confirmed <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-condition-ver-status.html\">ConditionVerificationStatus</a>#confirmed)</span></p><p><b>category</b>: Problem <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#55607006; <a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-condition-category.html\">Condition Category Codes</a>#problem-list-item)</span></p><p><b>severity</b>: Mild <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#255604002)</span></p><p><b>code</b>: Fever <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#386661006)</span></p><p><b>bodySite</b>: Entire body as a whole <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#38266002)</span></p><p><b>subject</b>: <a href=\"patient-example-f201-roel.html\">Patient/f201: Roel</a> &quot;Roel&quot;</p><p><b>encounter</b>: <a href=\"encounter-example-f201-20130404.html\">Encounter/f201</a></p><p><b>onset</b>: 2013-04-02</p><p><b>abatement</b>: around April 9, 2013</p><p><b>recordedDate</b>: 2013-04-04</p><blockquote><p><b>participant</b></p><p><b>function</b>: Enterer <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-provenance-participant-type.html\">Provenance participant type</a>#enterer)</span></p><p><b>actor</b>: <a href=\"practitioner-example-f201-ab.html\">Practitioner/f201</a> &quot;Dokter Bronsig&quot;</p></blockquote><blockquote><p><b>participant</b></p><p><b>function</b>: Verifier <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-provenance-participant-type.html\">Provenance participant type</a>#verifier)</span></p><p><b>actor</b>: <a href=\"practitioner-example-f201-ab.html\">Practitioner/f201</a> &quot;Dokter Bronsig&quot;</p></blockquote><h3>Evidences</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td><td><b>Reference</b></td></tr><tr><td>*</td><td><span title=\" Problem is confirmed by 39 degrees Celsius \">degrees C <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#258710007)</span></span></td><td><a href=\"observation-example-f202-temperature.html\">Observation/f202: Temperature</a></td></tr></table></div>"
  },
  "identifier" : [{
    "value" : "12345"
  }],
  "clinicalStatus" : {
    "coding" : [{
      "system" : "http://terminology.hl7.org/CodeSystem/condition-clinical",
      "code" : "resolved"
    }]
  },
  "verificationStatus" : {
    "coding" : [{
      "system" : "http://terminology.hl7.org/CodeSystem/condition-ver-status",
      "code" : "confirmed"
    }]
  },
  "category" : [{
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "55607006",
      "display" : "Problem"
    },
    {
      "system" : "http://terminology.hl7.org/CodeSystem/condition-category",
      "code" : "problem-list-item"
    }]
  }],
  "severity" : {
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "255604002",
      "display" : "Mild"
    }]
  },
  "code" : {
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "386661006",
      "display" : "Fever"
    }]
  },
  "bodySite" : [{
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "38266002",
      "display" : "Entire body as a whole"
    }]
  }],
  "subject" : {
    "reference" : "Patient/f201",
    "display" : "Roel"
  },
  "encounter" : {
    "reference" : "Encounter/f201"
  },
  "onsetDateTime" : "2013-04-02",
  "abatementString" : "around April 9, 2013",
  "recordedDate" : "2013-04-04",
  "participant" : [{
    "function" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/provenance-participant-type",
        "code" : "enterer",
        "display" : "Enterer"
      }]
    },
    "actor" : {
      "reference" : "Practitioner/f201"
    }
  },
  {
    "function" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/provenance-participant-type",
        "code" : "verifier",
        "display" : "Verifier"
      }]
    },
    "actor" : {
      "reference" : "Practitioner/f201"
    }
  }],
  "evidence" : [{
    "concept" : {
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "258710007",
        "display" : "degrees C"
      }]
    },
    "reference" : {
      "reference" : "Observation/f202",
      "display" : "Temperature"
    }
  }]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.