This page is part of the FHIR Specification (v4.0.1: R4 - Mixed Normative and STU) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
Specimen Reject Example (id = "unsat")
<?xml version="1.0" encoding="UTF-8"?> <Observation xmlns="http://hl7.org/fhir"> <id value="unsat"/> <!-- urn:oid:2.16.840.1.113883.4.642.1.7 --> <!-- 2.16.840.1.113883.4.642.1.118 --> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : unsat</p> <p> <b> identifier</b> : 6323 (OFFICIAL)</p> <p> <b> status</b> : cancelled</p> <p> <b> code</b> : Glucose [Moles/volume] in Blood <span> (Details : {LOINC code '15074-8' = 'Glucose [Moles/volume] in Blood', given as 'Glucose [Moles/volume] in Blood'})</span> </p> <p> <b> subject</b> : <a> P. van de Heuvel</a> </p> <p> <b> effective</b> : 02/04/2013 9:30:10 AM --> 05/04/2013 9:30:10 AM</p> <p> <b> issued</b> : 03/04/2013 3:30:10 PM</p> <p> <b> performer</b> : <a> A. Langeveld</a> </p> <p> <b> dataAbsentReason</b> : Specimen unsatisfactory for evaluation <span> (Details : {SNOMED CT code '125154007' = 'Specimen unsatisfactory for evaluation', given as 'Specimen unsatisfactory for evaluation'})</span> </p> <p> <b> note</b> : Tube broken in transit and sample leaked</p> <h3> ReferenceRanges</h3> <table> <tr> <td> -</td> <td> <b> Low</b> </td> <td> <b> High</b> </td> </tr> <tr> <td> *</td> <td> 3.1 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span> </td> <td> 6.2 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span> </td> </tr> </table> </div> </text> <identifier> <use value="official"/> <system value="http://www.bmc.nl/zorgportal/identifiers/observations"/> <value value="6323"/> </identifier> <status value="cancelled"/> <code> <coding> <system value="http://loinc.org"/> <code value="15074-8"/> <display value="Glucose [Moles/volume] in Blood"/> </coding> </code> <subject> <reference value="Patient/f001"/> <display value="P. van de Heuvel"/> </subject> <effectivePeriod> <start value="2013-04-02T09:30:10+01:00"/> <end value="2013-04-05T09:30:10+01:00"/> </effectivePeriod> <issued value="2013-04-03T15:30:10+01:00"/> <performer> <reference value="Practitioner/f005"/> <display value="A. Langeveld"/> </performer> <dataAbsentReason> <coding> <system value="http://snomed.info/sct"/> <code value="125154007"/> <display value="Specimen unsatisfactory for evaluation"/> </coding> </dataAbsentReason> <note> <text value="Tube broken in transit and sample leaked"/> </note> <referenceRange> <low> <value value="3.1"/> <unit value="mmol/l"/> <system value="http://unitsofmeasure.org"/> <code value="mmol/L"/> </low> <high> <value value="6.2"/> <unit value="mmol/l"/> <system value="http://unitsofmeasure.org"/> <code value="mmol/L"/> </high> </referenceRange> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.