Release 5

This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Example Observation/f203 (XML)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Real-world patient - CO2 (id = "f203")

<?xml version="1.0" encoding="UTF-8"?>

<Observation xmlns="http://hl7.org/fhir">
  <id value="f203"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Observation</b> <a name="f203"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation &quot;f203&quot; </p> </div> <p> <b> identifier</b> : id: 1304-03720-Bicarbonate</p> <p> <b> status</b> : <span title="  Bicarbonate was measured on April fourth  ">final</span> </p> <p> <b> code</b> : Bicarbonate [Moles/?volume] in Serum <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a> #1963-8; <a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #365722008 &quot;Bicarbonate level&quot;)</span> </p> <p> <b> subject</b> : <a href="patient-example-f201-roel.html">Patient/f201: Roel</a>  &quot;Roel&quot;</p> <p> <b> issued</b> : 5 Apr 2013, 12:34:00 am</p> <p> <b> performer</b> : <a href="practitioner-example-f202-lm.html">Practitioner/f202: Luigi Maas</a>  &quot;Luigi Maas&quot;</p> <p> <b> value</b> : 28 mmol/L<span style="background: LightGoldenRodYellow"> (Details: SNOMED CT code 258813002 = 'mM')</span> </p> <p> <b> interpretation</b> : Serum bicarbonate level normal <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #166698001; <a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-ObservationInterpretation.html">ObservationInterpretation</a> #N)</span> </p> <p> <b> method</b> : <span title="  The observation is complete  &amp;#10;  No reliability concerns  ">enzymatic method <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span> </span> </p> <h3> ReferenceRanges</h3> <table class="grid"><tr> <td> -</td> <td> <b> Low</b> </td> <td> <b> High</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> <span title="  Healthy bicarbonate level ranges from 22mmol/L to 29mmol/L  ">22</span> </td> <td> 29</td> <td> Normal Range <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-referencerange-meaning.html">Observation Reference Range Meaning Codes</a> #normal)</span> </td> </tr> </table> </div> </text> <identifier> 
    <system value="https://intranet.aumc.nl/labvalues"/>     <!--    Does not exist    --><value value="1304-03720-Bicarbonate"/> 
  </identifier>     <!--    Bicarbonate was measured on April fourth    --><status value="final"/> 
  <code>     <!--    Kind of observation = Bicarbonate LOINC and SNOMED CT translations here - Note
     in the US the primary code will be LOINC per meaningful use.  Further SNOMED CT
      has acceeded to LOINC being the primary coding system for vitals and anthropromorphic
     measures.  SNOMED CT is required in some countries such as the UK.   --><coding> 
      <system value="http://loinc.org"/> 
      <code value="1963-8"/> 
      <display value="Bicarbonate [Moles/?volume] in Serum"/> 
    </coding> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="365722008"/> 
      <display value="Bicarbonate level"/> 
    </coding> 
  </code> 
  <subject> 
    <reference value="Patient/f201"/> 
    <display value="Roel"/> 
  </subject> 
  <issued value="2013-04-04T14:34:00+01:00"/> 
  <performer> 
    <reference value="Practitioner/f202"/> 
    <display value="Luigi Maas"/> 
  </performer> 
  <valueQuantity>     <!--    Bicarbonate=28mmol/L    --><value value="28"/> 
    <unit value="mmol/L"/> 
    <system value="http://snomed.info/sct"/> 
    <code value="258813002"/> 
  </valueQuantity> 
  <interpretation> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="166698001"/> 
      <display value="Serum bicarbonate level normal"/> 
    </coding> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/> 
      <code value="N"/> 
    </coding> 
  </interpretation>     <!--    The observation is complete    -->    <!--    No reliability concerns    --><method>     <!--    Method was enzymatic method    --><text value="enzymatic method"/> 
  </method> 
  <referenceRange>     <!--    Healthy bicarbonate level ranges from 22mmol/L to 29mmol/L    --><low> 
      <value value="22"/> 
    </low> 
    <high> 
      <value value="29"/> 
    </high> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/referencerange-meaning"/> 
        <code value="normal"/> 
        <display value="Normal Range"/> 
      </coding> 
    </type> 
  </referenceRange> 
</Observation> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.