Release 5

This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Example Observation/f003 (Narrative)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile Observation.


Generated Narrative: Observation

Resource Observation "f003"

identifier: id: 6325 (use: OFFICIAL)

status: final

code: Carbon dioxide in blood (LOINC#11557-6)

subject: Patient/f001: P. van de Heuvel "Pieter VAN DE HEUVEL"

effective: 2013-04-02T10:30:10+01:00

issued: 4 Apr 2013, 1:30:10 am

performer: Practitioner/f005: A. Langeveld "Langeveld ANNE"

value: 6.2 kPa (Details: UCUM code kPa = 'kPa')

interpretation: High (ObservationInterpretation#H)

ReferenceRanges

-LowHigh
*4.8 kPa (Details: UCUM code kPa = 'kPa')6.0 kPa (Details: UCUM code kPa = 'kPa')

 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.