This page is part of the FHIR Core Extensions Registry (v5.1.0: Release 5.1) based on FHIR (HL7® FHIR® Standard) v5.0.0. This is the current published version. For a full list of available versions, see the Directory of published versions
Page standards status: Trial-use | Maturity Level: 3 |
<SearchParameter xmlns="http://hl7.org/fhir">
<id value="device-extensions-Device-din"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><h2>Din <a style="padding-left: 3px; padding-right: 3px; border: 1px grey solid; font-weight: bold; color: black; background-color: #fff5e6" href="http://hl7.org/fhir/R5/versions.html#std-process" title="Standards Status = Trial Use ">TU</a></h2><p>Parameter <code>din</code>:<code>token</code></p><div><p>The donation identification number (DIN)</p>
</div><table class="grid"><tr><td>Resource</td><td><a href="http://hl7.org/fhir/R5/device.html">Device</a></td></tr><tr><td>Expression</td><td><code>Device.extension('http://hl7.org/fhir/SearchParameter/device-extensions-Device-din').value</code></td></tr><tr><td>Processing Mode</td><td>Normal</td></tr><tr><td>Multiples</td><td><ul><li>multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true</li><li>multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true</li></ul></td></tr></table></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
<valueCode value="trial-use"/>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
<valueInteger value="3"/>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="dev"/>
</extension>
<url
value="http://hl7.org/fhir/SearchParameter/device-extensions-Device-din"/>
<identifier>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.4.642.31.19"/>
</identifier>
<version value="5.1.0"/>
<name value="Din"/>
<title value="din"/>
<status value="active"/>
<experimental value="false"/>
<date value="2024-04-27T18:54:50+10:00"/>
<publisher value="HL7 International / Health Care Devices"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/healthcaredevices"/>
</telecom>
</contact>
<description value="The donation identification number (DIN)"/>
<jurisdiction>
<coding>
<system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
<code value="001"/>
</coding>
</jurisdiction>
<code value="din"/>
<base value="Device"/>
<type value="token"/>
<expression
value="Device.extension('http://hl7.org/fhir/SearchParameter/device-extensions-Device-din').value"/>
<processingMode value="normal"/>
</SearchParameter>