FHIR Extensions Pack
5.1.0-snapshot1 - Working Copy International flag

This page is part of the FHIR Core Extensions Registry (v5.1.0-snapshot1: Release 5.1) based on FHIR (HL7® FHIR® Standard) v5.0.0. The current version which supersedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions

: Protective Factor Reference SearchParameter - JSON Representation

Page standards status: Draft

Raw json | Download


{
  "resourceType" : "SearchParameter",
  "id" : "workflow-protectiveFactorRef",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2>ProtectiveFactorRefSearchParameter <a style=\"padding-left: 3px; padding-right: 3px; border: 1px grey solid; font-weight: bold; color: black; background-color: #efefef\" href=\"http://hl7.org/fhir/R5/versions.html#std-process\" title=\"Standards Status = Draft\">D</a></h2><p>Parameter <code>workflow-protectiveFactorRef</code>:<code>reference</code></p><div><p>SearchParameter for Protective Factor Extension with Reference data type</p>\n</div><table class=\"grid\"><tr><td>Resources</td><td><a href=\"http://hl7.org/fhir/R5/careplan.html\">CarePlan</a>, <a href=\"http://hl7.org/fhir/R5/communicationrequest.html\">CommunicationRequest</a>, <a href=\"http://hl7.org/fhir/R5/goal.html\">Goal</a></td></tr><tr><td>Expression</td><td><code>CarePlan.activity.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference |                      CommunicationRequest.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference |                      Goal.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference</code></td></tr><tr><td>Processing Mode</td><td>Normal</td></tr><tr><td>Multiples</td><td><ul><li>multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true</li><li>multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true</li></ul></td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode" : "draft"
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "fhir"
    }
  ],
  "url" : "http://hl7.org/fhir/SearchParameter/workflow-protectiveFactorRef",
  "identifier" : [
    {
      "system" : "urn:ietf:rfc:3986",
      "value" : "urn:oid:2.16.840.1.113883.4.642.31.4"
    }
  ],
  "version" : "5.1.0-snapshot1",
  "name" : "ProtectiveFactorRefSearchParameter",
  "title" : "Protective Factor Reference SearchParameter",
  "status" : "draft",
  "experimental" : true,
  "date" : "2024-03-12T13:30:10+11:00",
  "publisher" : "HL7 International / FHIR Infrastructure",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description" : "SearchParameter for Protective Factor Extension with Reference data type",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001"
        }
      ]
    }
  ],
  "code" : "workflow-protectiveFactorRef",
  "base" : [
    "CarePlan",
    "CommunicationRequest",
    "Goal"
  ],
  "type" : "reference",
  "expression" : "CarePlan.activity.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference |                      CommunicationRequest.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference |                      Goal.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference",
  "processingMode" : "normal"
}