This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
ValueSet Example defining codes using an inline code system
{ "resourceType": "ValueSet", "id": "example-inline", "meta": { "profile": [ "http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition" ] }, "text": { "status": "generated", "div": "<div>\n \n \n <p>Value set "ACME Codes for Cholesterol": This is an example value set that includes \n all the codes for serum cholesterol defined by ACME inc.</p>\n \n \n <p>Developed by: FHIR project team (example)</p>\n \n \n <p>Published for testing on 13-June 2012</p>\n \n \n <p>This value set includes all the ACME codes for serum cholesterol:</p>\n\t\t\t\n \n <table class=\"grid\">\n\t\t\t \n \n <tr>\n\t\t\t\t \n \n <td>\n \n <b>Code</b>\n \n </td>\n\t\t\t\t \n \n <td>\n \n <b>Display</b>\n \n </td>\n\t\t\t\t \n \n <td>\n \n <b>Definition</b>\n \n </td>\n\t\t\t\t\n \n </tr>\n\t\t\t \n \n <tr>\n\t\t\t\t \n \n <td>chol-mmol</td>\n\t\t\t\t \n \n <td>SChol (mmol/L)</td>\n\t\t\t\t \n \n <td>Serum Cholesterol, in mmol/L</td>\n\t\t\t\t\n \n </tr>\n\t\t\t \n \n <tr>\n\t\t\t\t \n \n <td>chol-mass</td>\n\t\t\t\t \n \n <td>SChol (mg/L)</td>\n\t\t\t\t \n \n <td>Serum Cholesterol, in mg/L</td>\n\t\t\t\t\n \n </tr>\n\t\t\t \n \n <tr>\n\t\t\t\t \n \n <td>chol</td>\n\t\t\t\t \n \n <td>SChol</td>\n\t\t\t\t \n \n <td>Serum Cholesterol</td>\n\t\t\t\t\n \n </tr>\n\t\t\t\n \n </table>\n \n \n </div>" }, "url": "http://hl7.org/fhir/ValueSet/example-inline", "_url": { "fhir_comments": [ " \n\t for this example, we use a real URI, since this example does have a canonical address\n\t\tat which it's posted. Alternatively, We could have used an OID, or a UUID " ] }, "identifier": { "fhir_comments": [ " an imaginary identifier. This is a non FHIR identifier - might be used in a \n\t v2 context (though you always need to translate namespaces for v2) " ], "system": "http://acme.com/identifiers/valuesets", "value": "loinc-cholesterol-inl" }, "version": "20150622", "_version": { "fhir_comments": [ " for version, we are going to simply use the day of publication. This is also \n arbitrary - whatever is here is what people use to refer to the version. \n Could also be a UUID too " ] }, "name": "ACME Codes for Cholesterol in Serum/Plasma", "_name": { "fhir_comments": [ " set of loinc codes for cholesterol for LONC 2.36 " ] }, "status": "draft", "experimental": true, "publisher": "HL7 International", "contact": [ { "name": "FHIR project team", "telecom": [ { "system": "other", "value": "http://hl7.org/fhir" } ] } ], "date": "2015-06-22", "description": "This is an example value set that includes all the ACME codes for serum/plasma cholesterol from v2.36.", "codeSystem": { "fhir_comments": [ " \n\t\tThis value set publishes the underlying definition of the ACME code system\n\t\tWe don't keep track of authorship etc. here - we assume that ACME has a\n\t\tsystem for that. We're just representing the public face of the code \n\t\tsystem for external users\n\t " ], "system": "http://acme.com/config/fhir/codesystems/cholesterol", "_system": { "fhir_comments": [ " \n\t\t\tnote that since we give a literal URL here, there's an expectation \n\t\t\tthat accessing that URL will give some form of representation of \n\t\t\tthe full code system, or a pointer about how to get more infomration. \n\t\n\t\t\tThis is not an absolute requirement, but it may be enforced by some \n\t\t\tservers - for instance, the HL7 valueset registry will. " ] }, "version": "4.2.3", "_version": { "fhir_comments": [ " version is not mandatory, but is highly recommended. Note that \n\t\t\tyou should change the identify of the code system if existing codes \n\t\t\tare redefined " ] }, "caseSensitive": true, "_caseSensitive": { "fhir_comments": [ " it's often unstated - are codes case sensitive or not. And \n it can be the cause of operational or clinical safety problems. \n So FHIR requires that it always be specified. " ] }, "concept": [ { "fhir_comments": [ " \n\t\t\tACME's defined definitions. Note that these are not \n\t\t\t*good* definitions - but they are very commonly the kind \n\t\t\tof definitions that are encountered in production\n\t\t " ], "code": "chol-mmol", "display": "SChol (mmol/L)", "definition": "Serum Cholesterol, in mmol/L", "designation": [ { "use": { "system": "http://acme.com/config/fhir/codesystems/internal", "code": "internal-label" }, "value": "From ACME POC Testing" } ] }, { "code": "chol-mass", "display": "SChol (mg/L)", "definition": "Serum Cholesterol, in mg/L", "designation": [ { "use": { "system": "http://acme.com/config/fhir/codesystems/internal", "code": "internal-label" }, "value": "From Paragon Labs" } ] }, { "code": "chol", "display": "SChol", "definition": "Serum Cholesterol", "designation": [ { "use": { "system": "http://acme.com/config/fhir/codesystems/internal", "code": "internal-label" }, "value": "Obdurate Labs uses this with both kinds of units..." } ] } ] } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.