This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
ShEx statement for devicedefinition
PREFIX fhir: <http://hl7.org/fhir/> PREFIX fhirvs: <http://hl7.org/fhir/ValueSet/> PREFIX xsd: <http://www.w3.org/2001/XMLSchema#> PREFIX rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#> IMPORT <uri.shex> IMPORT <code.shex> IMPORT <Range.shex> IMPORT <string.shex> IMPORT <Period.shex> IMPORT <Coding.shex> IMPORT <integer.shex> IMPORT <boolean.shex> IMPORT <markdown.shex> IMPORT <Quantity.shex> IMPORT <Reference.shex> IMPORT <Identifier.shex> IMPORT <Annotation.shex> IMPORT <Attachment.shex> IMPORT <Organization.shex> IMPORT <ContactPoint.shex> IMPORT <UsageContext.shex> IMPORT <DomainResource.shex> IMPORT <CodeableConcept.shex> IMPORT <BackboneElement.shex> IMPORT <RelatedArtifact.shex> IMPORT <ProductShelfLife.shex> IMPORT <CodeableReference.shex> start=@<DeviceDefinition> AND {fhir:nodeRole [fhir:treeRoot]} # An instance of a medical-related component of a medical device <DeviceDefinition> EXTENDS @<DomainResource> CLOSED { a [fhir:DeviceDefinition]?; fhir:nodeRole [fhir:treeRoot]?; fhir:description @<markdown>?; # Additional information to describe # the device fhir:identifier @<OneOrMore_Identifier>?; # Instance identifier fhir:udiDeviceIdentifier @<OneOrMore_DeviceDefinition.udiDeviceIdentifier>?; # Unique Device Identifier (UDI) # Barcode string fhir:regulatoryIdentifier @<OneOrMore_DeviceDefinition.regulatoryIdentifier>?; # Regulatory identifier(s) # associated with this device fhir:partNumber @<string>?; # The part number or catalog number # of the device fhir:manufacturer @<Reference> AND {fhir:link @<Organization> ? }?; # Name of device manufacturer fhir:deviceName @<OneOrMore_DeviceDefinition.deviceName>?; # The name or names of the device as # given by the manufacturer fhir:modelNumber @<string>?; # The catalog or model number for # the device for example as defined # by the manufacturer fhir:classification @<OneOrMore_DeviceDefinition.classification>?; # What kind of device or device # system this is fhir:conformsTo @<OneOrMore_DeviceDefinition.conformsTo>?; # Identifies the standards, # specifications, or formal # guidances for the capabilities # supported by the device fhir:hasPart @<OneOrMore_DeviceDefinition.hasPart>?; # A device, part of the current one fhir:packaging @<OneOrMore_DeviceDefinition.packaging>?; # Information about the packaging of # the device, i.e. how the device is # packaged fhir:version @<OneOrMore_DeviceDefinition.version>?; # The version of the device or # software fhir:safety @<OneOrMore_CodeableConcept>?; # Safety characteristics of the # device fhir:shelfLifeStorage @<OneOrMore_ProductShelfLife>?; # Shelf Life and storage information fhir:languageCode @<OneOrMore_CodeableConcept>?; # Language code for the # human-readable text strings # produced by the device (all # supported) fhir:property @<OneOrMore_DeviceDefinition.property>?; # Inherent, essentially fixed, # characteristics of this kind of # device, e.g., time properties, # size, etc fhir:owner @<Reference> AND {fhir:link @<Organization> ? }?; # Organization responsible for device fhir:contact @<OneOrMore_ContactPoint>?; # Details for human/organization for # support fhir:link @<OneOrMore_DeviceDefinition.link>?; # An associated device, attached to, # used with, communicating with or # linking a previous or new device # model to the focal device fhir:note @<OneOrMore_Annotation>?; # Device notes and comments fhir:material @<OneOrMore_DeviceDefinition.material>?; # A substance used to create the # material(s) of which the device is # made fhir:productionIdentifierInUDI @<OneOrMore_code> AND {fhir:v @fhirvs:device-productidentifierinudi}?; # lot-number | manufactured-date | # serial-number | expiration-date | # biological-source | # software-version fhir:guideline @<DeviceDefinition.guideline>?; # Information aimed at providing # directions for the usage of this # model of device fhir:correctiveAction @<DeviceDefinition.correctiveAction>?; # Tracking of latest field safety # corrective action fhir:chargeItem @<OneOrMore_DeviceDefinition.chargeItem>?; # Billing code or reference # associated with the device } # The version of the device or software <DeviceDefinition.version> EXTENDS @<BackboneElement> CLOSED { fhir:type @<CodeableConcept>?; # The type of the device version, # e.g. manufacturer, approved, # internal fhir:component @<Identifier>?; # The hardware or software module of # the device to which the version # applies fhir:value @<string>; # The version text } # Unique Device Identifier (UDI) Barcode string <DeviceDefinition.udiDeviceIdentifier> EXTENDS @<BackboneElement> CLOSED { fhir:deviceIdentifier @<string>; # The identifier that is to be # associated with every Device that # references this DeviceDefintiion # for the issuer and jurisdiction # provided in the # DeviceDefinition.udiDeviceIdenti- # fier fhir:issuer @<uri>; # The organization that assigns the # identifier algorithm fhir:jurisdiction @<uri>; # The jurisdiction to which the # deviceIdentifier applies fhir:marketDistribution @<OneOrMore_DeviceDefinition.udiDeviceIdentifier.marketDistribution>?; # Indicates whether and when the # device is available on the market } # Information about the packaging of the device, i.e. how the device is packaged <DeviceDefinition.packaging> EXTENDS @<BackboneElement> CLOSED { fhir:identifier @<Identifier>?; # Business identifier of the # packaged medication fhir:type @<CodeableConcept>?; # A code that defines the specific # type of packaging fhir:count @<integer>?; # The number of items contained in # the package (devices or # sub-packages) fhir:distributor @<OneOrMore_DeviceDefinition.packaging.distributor>?; # An organization that distributes # the packaged device fhir:udiDeviceIdentifier @<OneOrMore_DeviceDefinition.udiDeviceIdentifier>?; # Unique Device Identifier (UDI) # Barcode string on the packaging fhir:packaging @<OneOrMore_DeviceDefinition.packaging>?; # Allows packages within packages } # Information aimed at providing directions for the usage of this model of device <DeviceDefinition.guideline> EXTENDS @<BackboneElement> CLOSED { fhir:useContext @<OneOrMore_UsageContext>?; # The circumstances that form the # setting for using the device fhir:usageInstruction @<markdown>?; # Detailed written and visual # directions for the user on how to # use the device fhir:relatedArtifact @<OneOrMore_RelatedArtifact>?; # A source of information or # reference for this guideline fhir:indication @<OneOrMore_CodeableConcept>?; # A clinical condition for which the # device was designed to be used fhir:contraindication @<OneOrMore_CodeableConcept>?; # A specific situation when a device # should not be used because it may # cause harm fhir:warning @<OneOrMore_CodeableConcept>?; # Specific hazard alert information # that a user needs to know before # using the device fhir:intendedUse @<string>?; # A description of the general # purpose or medical use of the # device or its function } # Indicates whether and when the device is available on the market <DeviceDefinition.udiDeviceIdentifier.marketDistribution> EXTENDS @<BackboneElement> CLOSED { fhir:marketPeriod @<Period>; # Begin and end dates for the # commercial distribution of the # device fhir:subJurisdiction @<uri>; # National state or territory where # the device is commercialized } # Billing code or reference associated with the device <DeviceDefinition.chargeItem> EXTENDS @<BackboneElement> CLOSED { fhir:chargeItemCode @<CodeableReference>; # The code or reference for the # charge item fhir:count @<Quantity>; # Coefficient applicable to the # billing code fhir:effectivePeriod @<Period>?; # A specific time period in which # this charge item applies fhir:useContext @<OneOrMore_UsageContext>?; # The context to which this charge # item applies } # A device, part of the current one <DeviceDefinition.hasPart> EXTENDS @<BackboneElement> CLOSED { fhir:reference @<Reference> AND {fhir:link @<DeviceDefinition> ? }; # Reference to the part fhir:count @<integer>?; # Number of occurrences of the part } # An organization that distributes the packaged device <DeviceDefinition.packaging.distributor> EXTENDS @<BackboneElement> CLOSED { fhir:name @<string>?; # Distributor's human-readable name fhir:organizationReference @<OneOrMore_Reference_Organization>?; # Distributor as an Organization # resource } # Allows packages within packages <DeviceDefinition.packaging.packagingnull> CLOSED { } # What kind of device or device system this is <DeviceDefinition.classification> EXTENDS @<BackboneElement> CLOSED { fhir:type @<CodeableConcept>; # A classification or risk class of # the device model fhir:justification @<OneOrMore_RelatedArtifact>?; # Further information qualifying # this classification of the device # model } # The name or names of the device as given by the manufacturer <DeviceDefinition.deviceName> EXTENDS @<BackboneElement> CLOSED { fhir:name @<string>; # A name that is used to refer to # the device fhir:type @<code> AND {fhir:v @fhirvs:device-nametype}; # registered-name | # user-friendly-name | # patient-reported-name } # Tracking of latest field safety corrective action <DeviceDefinition.correctiveAction> EXTENDS @<BackboneElement> CLOSED { fhir:recall @<boolean>; # Whether the corrective action was # a recall fhir:scope @<code> AND {fhir:v @fhirvs:device-correctiveactionscope}?; # model | lot-numbers | # serial-numbers fhir:period @<Period>; # Start and end dates of the # corrective action } # A substance used to create the material(s) of which the device is made <DeviceDefinition.material> EXTENDS @<BackboneElement> CLOSED { fhir:substance @<CodeableConcept>; # A relevant substance that the # device contains, may contain, or # is made of fhir:alternate @<boolean>?; # Indicates an alternative material # of the device fhir:allergenicIndicator @<boolean>?; # Whether the substance is a known # or suspected allergen } # An associated device, attached to, used with, communicating with or linking a previous or new device model to the focal device <DeviceDefinition.link> EXTENDS @<BackboneElement> CLOSED { fhir:relation @<Coding>; # The type indicates the # relationship of the related device # to the device instance fhir:relatedDevice @<CodeableReference>; # A reference to the linked device } # Regulatory identifier(s) associated with this device <DeviceDefinition.regulatoryIdentifier> EXTENDS @<BackboneElement> CLOSED { fhir:type @<code> AND {fhir:v @fhirvs:devicedefinition-regulatory-identifier-type}; # basic | master | license fhir:deviceIdentifier @<string>; # The identifier itself fhir:issuer @<uri>; # The organization that issued this # identifier fhir:jurisdiction @<uri>; # The jurisdiction to which the # deviceIdentifier applies } # Inherent, essentially fixed, characteristics of this kind of device, e.g., time properties, size, etc <DeviceDefinition.property> EXTENDS @<BackboneElement> CLOSED { fhir:type @<CodeableConcept>; # Code that specifies the property # being represented fhir:value @<Quantity> OR @<CodeableConcept> OR @<string> OR @<boolean> OR @<integer> OR @<Range> OR @<Attachment> ; # Value of the property } # Identifies the standards, specifications, or formal guidances for the capabilities supported by the device <DeviceDefinition.conformsTo> EXTENDS @<BackboneElement> CLOSED { fhir:category @<CodeableConcept>?; # Describes the common type of the # standard, specification, or formal # guidance fhir:specification @<CodeableConcept>; # Identifies the standard, # specification, or formal guidance # that the device adheres to the # Device Specification type fhir:version @<OneOrMore_string>?; # The specific form or variant of # the standard, specification or # formal guidance fhir:source @<OneOrMore_RelatedArtifact>?; # Standard, regulation, # certification, or guidance # website, document, or other # publication, or similar, # supporting the conformance } #---------------------- Cardinality Types (OneOrMore) ------------------- <OneOrMore_Identifier> CLOSED { rdf:first @<Identifier> ; rdf:rest [rdf:nil] OR @<OneOrMore_Identifier> } <OneOrMore_DeviceDefinition.udiDeviceIdentifier> CLOSED { rdf:first @<DeviceDefinition.udiDeviceIdentifier> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.udiDeviceIdentifier> } <OneOrMore_DeviceDefinition.regulatoryIdentifier> CLOSED { rdf:first @<DeviceDefinition.regulatoryIdentifier> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.regulatoryIdentifier> } <OneOrMore_DeviceDefinition.deviceName> CLOSED { rdf:first @<DeviceDefinition.deviceName> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.deviceName> } <OneOrMore_DeviceDefinition.classification> CLOSED { rdf:first @<DeviceDefinition.classification> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.classification> } <OneOrMore_DeviceDefinition.conformsTo> CLOSED { rdf:first @<DeviceDefinition.conformsTo> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.conformsTo> } <OneOrMore_DeviceDefinition.hasPart> CLOSED { rdf:first @<DeviceDefinition.hasPart> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.hasPart> } <OneOrMore_DeviceDefinition.packaging> CLOSED { rdf:first @<DeviceDefinition.packaging> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.packaging> } <OneOrMore_DeviceDefinition.version> CLOSED { rdf:first @<DeviceDefinition.version> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.version> } <OneOrMore_CodeableConcept> CLOSED { rdf:first @<CodeableConcept> ; rdf:rest [rdf:nil] OR @<OneOrMore_CodeableConcept> } <OneOrMore_ProductShelfLife> CLOSED { rdf:first @<ProductShelfLife> ; rdf:rest [rdf:nil] OR @<OneOrMore_ProductShelfLife> } <OneOrMore_DeviceDefinition.property> CLOSED { rdf:first @<DeviceDefinition.property> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.property> } <OneOrMore_ContactPoint> CLOSED { rdf:first @<ContactPoint> ; rdf:rest [rdf:nil] OR @<OneOrMore_ContactPoint> } <OneOrMore_DeviceDefinition.link> CLOSED { rdf:first @<DeviceDefinition.link> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.link> } <OneOrMore_Annotation> CLOSED { rdf:first @<Annotation> ; rdf:rest [rdf:nil] OR @<OneOrMore_Annotation> } <OneOrMore_DeviceDefinition.material> CLOSED { rdf:first @<DeviceDefinition.material> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.material> } <OneOrMore_code> CLOSED { rdf:first @<code> ; rdf:rest [rdf:nil] OR @<OneOrMore_code> } <OneOrMore_DeviceDefinition.chargeItem> CLOSED { rdf:first @<DeviceDefinition.chargeItem> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.chargeItem> } <OneOrMore_DeviceDefinition.udiDeviceIdentifier.marketDistribution> CLOSED { rdf:first @<DeviceDefinition.udiDeviceIdentifier.marketDistribution> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.udiDeviceIdentifier.marketDistribution> } <OneOrMore_DeviceDefinition.packaging.distributor> CLOSED { rdf:first @<DeviceDefinition.packaging.distributor> ; rdf:rest [rdf:nil] OR @<OneOrMore_DeviceDefinition.packaging.distributor> } <OneOrMore_UsageContext> CLOSED { rdf:first @<UsageContext> ; rdf:rest [rdf:nil] OR @<OneOrMore_UsageContext> } <OneOrMore_RelatedArtifact> CLOSED { rdf:first @<RelatedArtifact> ; rdf:rest [rdf:nil] OR @<OneOrMore_RelatedArtifact> } <OneOrMore_Reference_Organization> CLOSED { rdf:first @<Reference> AND {fhir:link @<Organization> } ; rdf:rest [rdf:nil] OR @<OneOrMore_Reference_Organization> } <OneOrMore_string> CLOSED { rdf:first @<string> ; rdf:rest [rdf:nil] OR @<OneOrMore_string> } #---------------------- Value Sets ------------------------ # Device - Corrective action scope fhirvs:device-correctiveactionscope ["model" "lot-numbers" "serial-numbers"] # The type of name the device is referred by. fhirvs:device-nametype ["registered-name" "user-friendly-name" "patient-reported-name"] # Device Production Identifier in UDI fhirvs:device-productidentifierinudi ["lot-number" "manufactured-date" "serial-number" "expiration-date" "biological-source" "software-version"] # Regulatory Identifier type fhirvs:devicedefinition-regulatory-identifier-type ["basic" "master" "license"]
Usage note: every effort has been made to ensure that the ShEx files are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:24+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4 |
Compare to R4B |
|
Propose a change