Publish-box (todo)
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
Nonin20601PulseOx
{ "resourceType" : "Device", "id" : "Nonin20601PulseOx", "text" : { "status" : "generated", "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"Nonin20601PulseOx\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "Nonin20601PulseOx" </p></div><p><b>identifier</b>: System Identifier: 00-1C-05-04-00-00-78-25, Bluetooth Address: 00-1C-05-00-78-25</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>120343001125</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)120343001125(21)0400007825</td><td>unknown</td></tr></table><p><b>manufacturer</b>: Nonin Medical, Inc.</p><p><b>serialNumber</b>: 0400007825</p><h3>Names</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>Nonin_Medical_Inc._323552</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: Model 3150</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 "MDC_MOC_VMS_MDS_SIMP")</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></p><p><b>value</b>: 0.9C</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352)</span></p><p><b>value</b>: 1.0</p></blockquote><h3>ConformsTos</h3><table class=\"grid\"><tr><td>-</td><td><b>Specification</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528388)</span></td><td>1</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>value</b>: 4 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaPAN#4)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#532354.0)</span></p><p><b>value</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>value</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.0)</span></p><p><b>value</b>: real time clock supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.2)</span></p><p><b>value</b>: setting the time supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-relative-time <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.2)</span></p><p><b>value</b>: relative time supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_RES_ABS: Resolution of absolute time clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68222)</span></p><p><b>value</b>: 1000000 us<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code us = 'us')</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_RES_REL: Resolution of relative time clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68222)</span></p><p><b>value</b>: 1000000 us<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code us = 'us')</span></p></blockquote></div>" }, "identifier" : [{ "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers", "code" : "SYSID", "display" : "System Identifier" }] }, "system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680", "value" : "00-1C-05-04-00-00-78-25" }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers", "code" : "BTMAC", "display" : "Bluetooth Address" }] }, "system" : "http://hl7.org/fhir/sid/eui-48", "value" : "00-1C-05-00-78-25" }], "udiCarrier" : [{ "deviceIdentifier" : "120343001125", "issuer" : "http://hl7.org/fhir/NamingSystem/gs1-di", "jurisdiction" : "http://hl7.org/fhir/NamingSystem/fda-udi", "carrierHRF" : "(01)120343001125(21)0400007825", "entryType" : "unknown" }], "manufacturer" : "Nonin Medical, Inc.", "serialNumber" : "0400007825", "name" : [{ "value" : "Nonin_Medical_Inc._323552", "type" : "user-friendly-name" }], "modelNumber" : "Model 3150", "type" : [{ "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "65573", "display" : "MDC_MOC_VMS_MDS_SIMP" }], "text" : "MDC_MOC_VMS_MDS_SIMP: Personal Health Device" }], "version" : [{ "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "531976" }], "text" : "MDC_ID_PROD_SPEC_FW: Firmware revision" }, "value" : "0.9C" }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "532352" }], "text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" }, "value" : "1.0" }], "conformsTo" : [{ "specification" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "528388" }], "text" : "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter" }, "version" : "1" }], "property" : [{ "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "532353" }], "text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ContinuaPAN", "code" : "4" }] } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "532354.0" }], "text" : "regulation-status" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "N" }], "text" : "Device is Regulated" } }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "68220" }], "text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" }, "valueCodeableConcept" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "532224" }], "text" : "MDC_TIME_SYNC_NONE: No time synchronization" } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "68219.0" }], "text" : "mds-time-capab-real-time-clock" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "Y" }], "text" : "real time clock supported" } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "68219.2" }], "text" : "mds-time-capab-set-clock" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "Y" }], "text" : "setting the time supported" } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "68219.2" }], "text" : "mds-time-capab-relative-time" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "Y" }], "text" : "relative time supported" } }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "68222" }], "text" : "MDC_TIME_RES_ABS: Resolution of absolute time clock" }, "valueQuantity" : { "value" : 1000000, "system" : "http://unitsofmeasure.org", "code" : "us" } }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "68222" }], "text" : "MDC_TIME_RES_REL: Resolution of relative time clock" }, "valueQuantity" : { "value" : 1000000, "system" : "http://unitsofmeasure.org", "code" : "us" } }] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:24+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4 |
Compare to R4B |
|
Propose a change