AdministrationPublish-box (todo)
| Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
AndroidGatewayPHG
{
"resourceType" : "Device",
"id" : "AndroidGatewayPHG",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"AndroidGatewayPHG\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "AndroidGatewayPHG" </p></div><p><b>identifier</b>: System Identifier: 4C-4E-49-12-34-56-FF-FF</p><p><b>type</b>: MDC_MOC_VMS_MDS_AHD: Continua compliant Gateway <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531981 "MDC_MOC_VMS_MDS_AHD")</span></p><h3>Versions</h3><table class=\"grid\"><tr><td>-</td><td><b>Type</b></td><td><b>Value</b></td></tr><tr><td>*</td><td>MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352)</span></td><td>6.0</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>value</b>: 4 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaPAN#4)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532355)</span></p><p><b>value</b>: 0 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaHFS#0)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532355)</span></p><p><b>value</b>: 3 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaHFS#3)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532355)</span></p><p><b>value</b>: 7 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaHFS#7)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532355)</span></p><p><b>value</b>: 2 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaHFS#2)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532355)</span></p><p><b>value</b>: 6 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaHFS#6)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#532354.0)</span></p><p><b>value</b>: Device is Unregulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>value</b>: MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532226)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_ACCURACY: unknown code <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68221)</span></p><p><b>value</b>: 120000000 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://ucum.org\">UCUM</a>#us)</span></p></blockquote></div>"
},
"identifier" : [{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "SYSID",
"display" : "System Identifier"
}]
},
"system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value" : "4C-4E-49-12-34-56-FF-FF"
}],
"type" : [{
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531981",
"display" : "MDC_MOC_VMS_MDS_AHD"
}],
"text" : "MDC_MOC_VMS_MDS_AHD: Continua compliant Gateway"
}],
"version" : [{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532352"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
},
"value" : "6.0"
}],
"property" : [{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532353"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaPAN",
"code" : "4"
}]
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532355"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaHFS",
"code" : "0"
}]
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532355"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaHFS",
"code" : "3"
}]
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532355"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaHFS",
"code" : "7"
}]
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532355"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaHFS",
"code" : "2"
}]
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532355"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaHFS",
"code" : "6"
}]
}
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code" : "532354.0",
"display" : "regulation-status"
}]
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "Y"
}],
"text" : "Device is Unregulated"
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68220"
}],
"text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532226"
}],
"text" : "MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization"
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68221"
}],
"text" : "MDC_TIME_SYNC_ACCURACY: unknown code"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://unitsofmeasure.org",
"code" : "us"
}],
"text" : "120000000"
}
}]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:24+1100.