FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3

Device-example-udi1.ttl

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device

Raw Turtle, JSON-LD

Implantable device/UDI example GS-1 Format

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/Device/example-udi1> a fhir:Device;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "example-udi1"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-udi1</p><p><b>identifier</b>: 1234-5678-90AB-CDEF, Serial Number = 10987654d321</p><h3>Udis</h3><table><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Name</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>CarrierAIDC</b></td><td><b>Issuer</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>00844588003288</td><td>FHIR® Hip System</td><td><a>http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>{01}00844588003288{17}141120{10}7654321D{21}10987654d321</td><td>XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH</td><td><a>http://hl7.org/fhir/NamingSystem/gs1</a></td><td>barcode</td></tr></table><p><b>status</b>: active</p><p><b>type</b>: Coated femoral stem prosthesis, modular <span>(Details : {SNOMED CT code '468063009' = 'Coated femoral stem prosthesis, modular', given as 'Coated femoral stem prosthesis, modular'})</span></p><p><b>lotNumber</b>: 7654321D</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>expirationDate</b>: 20/11/2014</p><p><b>model</b>: PM/Octane 2014</p><p><b>patient</b>: <a>Patient/example</a></p><p><b>safety</b>: MR Unsafe <span>(Details : {urn:oid:2.16.840.1.113883.3.26.1.1 code 'mr-unsafe' = 'mr-unsafe', given as 'MR Unsafe'})</span></p></div>"
  ];
  fhir:Device.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "http://acme.com/devices/pacemakers/octane/serial" ];
     fhir:Identifier.value [ fhir:value "1234-5678-90AB-CDEF" ]
  ], [
     fhir:index 1;
     fhir:Identifier.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/identifier-type" ];
         fhir:Coding.code [ fhir:value "SNO" ]
       ]
     ];
     fhir:Identifier.value [ fhir:value "10987654d321" ]
  ];
  fhir:Device.udi [
     fhir:Device.udi.deviceIdentifier [ fhir:value "00844588003288" ];
     fhir:Device.udi.name [ fhir:value "FHIR® Hip System" ];
     fhir:Device.udi.jurisdiction [ fhir:value "http://hl7.org/fhir/NamingSystem/fda-udi" ];
     fhir:Device.udi.carrierHRF [ fhir:value "{01}00844588003288{17}141120{10}7654321D{21}10987654d321" ];
     fhir:Device.udi.carrierAIDC [ fhir:value "XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH"^^xsd:base64Binary ];
     fhir:Device.udi.issuer [ fhir:value "http://hl7.org/fhir/NamingSystem/gs1" ];
     fhir:Device.udi.entryType [ fhir:value "barcode" ]
  ];
  fhir:Device.status [ fhir:value "active"];
  fhir:Device.type [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:468063009;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "468063009" ];
       fhir:Coding.display [ fhir:value "Coated femoral stem prosthesis, modular" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Coated femoral stem prosthesis, modular" ]
  ];
  fhir:Device.lotNumber [ fhir:value "7654321D"];
  fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc"];
  fhir:Device.expirationDate [ fhir:value "2014-11-20"^^xsd:date];
  fhir:Device.model [ fhir:value "PM/Octane 2014"];
  fhir:Device.patient [
     fhir:link <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ]
  ];
  fhir:Device.safety [
     fhir:index 0;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "urn:oid:2.16.840.1.113883.3.26.1.1" ];
       fhir:Coding.code [ fhir:value "mr-unsafe" ];
       fhir:Coding.display [ fhir:value "MR Unsafe" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "MR Unsafe" ]
  ] .

<http://hl7.org/fhir/Patient/example> a fhir:Patient .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/Device/example-udi1.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://hl7.org/fhir/STU3/Device/example-udi1.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.