Release 4B

This page is part of the FHIR Specification (v4.3.0: R4B - STU). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Observation-example-rhstatus.ttl

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw Turtle (+ also see Turtle/RDF Format Specification)

An example of a blood Rh antigen measurement.

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/rdf#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/Observation/rhstatus> a fhir:Observation;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "rhstatus"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource &quot;rhstatus&quot; </p></div><p><b>status</b>: final</p><p><b>category</b>: Laboratory <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"codesystem-observation-category.html\">Observation Category Codes</a>#laboratory)</span></p><p><b>code</b>: Blood Group <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#883-9 &quot;ABO group [Type] in Blood&quot;)</span></p><p><b>subject</b>: <a href=\"todo.html\">Patient/infant</a></p><p><b>effective</b>: 2018-03-11T16:07:54Z</p><p><b>value</b>: A <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#112144000 &quot;Blood group A (finding)&quot;)</span></p></div>"
  ];
  fhir:Observation.status [ fhir:value "final"];
  fhir:Observation.category [
     fhir:index 0;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/observation-category" ];
       fhir:Coding.code [ fhir:value "laboratory" ];
       fhir:Coding.display [ fhir:value "Laboratory" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Laboratory" ]
  ];
  fhir:Observation.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a loinc:883-9;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "883-9" ];
       fhir:Coding.display [ fhir:value "ABO group [Type] in Blood" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Blood Group" ]
  ];
  fhir:Observation.subject [
     fhir:link <http://hl7.org/fhir/Patient/infant>;
     fhir:Reference.reference [ fhir:value "Patient/infant" ]
  ];
  fhir:Observation.effectiveDateTime [ fhir:value "2018-03-11T16:07:54+00:00"^^xsd:dateTime];
  fhir:Observation.valueCodeableConcept [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:112144000;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "112144000" ];
       fhir:Coding.display [ fhir:value "Blood group A (finding)" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "A" ]
  ] .

<http://hl7.org/fhir/Patient/infant> a fhir:Patient .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/Observation/rhstatus.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://build.fhir.org/Observation/rhstatus.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.