Release 4

This page is part of the FHIR Specification (v4.0.1: R4 - Mixed Normative and STU) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4B R4 R3

Adverseevent-example.json

Patient Care Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient, Practitioner, RelatedPerson

Raw JSON (canonical form + also see JSON Format Specification)

Example of adverseevent

{
  "resourceType": "AdverseEvent",
  "id": "example",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>identifier</b>: 49476534</p><p><b>actuality</b>: actual</p><p><b>category</b>: Product Use Error <span>(Details : {http://terminology.hl7.org/CodeSystem/adverse-event-category code 'product-use-error' = 'Product Use Error', given as 'Product Use Error'})</span></p><p><b>event</b>: This was a mild rash on the left forearm <span>(Details : {SNOMED CT code '304386008' = 'O/E - itchy rash', given as 'O/E - itchy rash'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>date</b>: 29/01/2017 12:34:56 PM</p><p><b>seriousness</b>: Non-serious <span>(Details : {http://terminology.hl7.org/CodeSystem/adverse-event-seriousness code 'Non-serious' = 'Non-serious', given as 'Non-serious'})</span></p><p><b>severity</b>: Mild <span>(Details : {http://terminology.hl7.org/CodeSystem/adverse-event-severity code 'mild' = 'Mild', given as 'Mild'})</span></p><p><b>recorder</b>: <a>Practitioner/example</a></p><h3>SuspectEntities</h3><table><tr><td>-</td><td><b>Instance</b></td></tr><tr><td>*</td><td><a>Medication/example</a></td></tr></table></div>"
  },
  "identifier": {
    "system": "http://acme.com/ids/patients/risks",
    "value": "49476534"
  },
  "actuality": "actual",
  "category": [
    {
      "coding": [
        {
          "system": "http://terminology.hl7.org/CodeSystem/adverse-event-category",
          "code": "product-use-error",
          "display": "Product Use Error"
        }
      ]
    }
  ],
  "event": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "304386008",
        "display": "O/E - itchy rash"
      }
    ],
    "text": "This was a mild rash on the left forearm"
  },
  "subject": {
    "reference": "Patient/example"
  },
  "date": "2017-01-29T12:34:56+00:00",
  "seriousness": {
    "coding": [
      {
        "system": "http://terminology.hl7.org/CodeSystem/adverse-event-seriousness",
        "code": "Non-serious",
        "display": "Non-serious"
      }
    ]
  },
  "severity": {
    "coding": [
      {
        "system": "http://terminology.hl7.org/CodeSystem/adverse-event-severity",
        "code": "mild",
        "display": "Mild"
      }
    ]
  },
  "recorder": {
    "reference": "Practitioner/example"
  },
  "suspectEntity": [
    {
      "instance": {
        "reference": "Medication/example"
      }
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.