DSTU2

This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-f204-creatinine.json

Raw JSON (canonical form)

Real-world patient - creatinine

{
  "resourceType": "Observation",
  "id": "f204",
  "text": {
    "fhir_comments": [
      "   The observation is complete   ",
      "   No reliability concerns   "
    ],
    "status": "generated",
    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f204</p><p><b>identifier</b>: 1304-03720-Creatinine</p><p><b>status</b>: final</p><p><b>code</b>: Creatinine(Serum) <span>(Details : {https://intranet.aumc.nl/labtestcodes code '20005' = '??', given as 'Creatinine(Serum)'})</span></p><p><b>subject</b>: <a>Roel</a></p><p><b>issued</b>: 04/04/2013 2:34:00 PM</p><p><b>performer</b>: <a>Luigi Maas</a></p><p><b>value</b>: 122 umol/L<span> (Details: SNOMED CT code 258814008 = '258814008')</span></p><p><b>interpretation</b>: Serum creatinine raised <span>(Details : {SNOMED CT code '166717003' = '166717003', given as 'Serum creatinine raised'}; {http://hl7.org/fhir/v2/0078 code 'H' = 'High)</span></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td><td><b>Meaning</b></td></tr><tr><td>*</td><td>64</td><td>104</td><td>Normal Range <span>(Details : {http://hl7.org/fhir/referencerange-meaning code 'normal' = 'Normal Range', given as 'Normal Range'})</span></td></tr></table></div>"
  },
  "identifier": [
    {
      "system": "https://intranet.aumc.nl/labvalues",
      "value": "1304-03720-Creatinine",
      "_value": {
        "fhir_comments": [
          "   Does not exist   "
        ]
      }
    }
  ],
  "status": "final",
  "_status": {
    "fhir_comments": [
      "   Creatinine was measured on April fourth   "
    ]
  },
  "code": {
    "coding": [
      {
        "fhir_comments": [
          "   Kind of observation = Serum Creatinine, Using only a local code in this example    "
        ],
        "system": "https://intranet.aumc.nl/labtestcodes",
        "code": "20005",
        "_code": {
          "fhir_comments": [
            "   Does not exist   "
          ]
        },
        "display": "Creatinine(Serum)"
      }
    ]
  },
  "subject": {
    "reference": "Patient/f201",
    "display": "Roel"
  },
  "issued": "2013-04-04T14:34:00+01:00",
  "performer": [
    {
      "reference": "Practitioner/f202",
      "display": "Luigi Maas"
    }
  ],
  "valueQuantity": {
    "value": 122,
    "_value": {
      "fhir_comments": [
        "   Creatinine=122mmol/L   "
      ]
    },
    "unit": "umol/L",
    "system": "http://snomed.info/sct",
    "code": "258814008"
  },
  "interpretation": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "166717003",
        "display": "Serum creatinine raised"
      },
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "code": "H"
      }
    ]
  },
  "referenceRange": [
    {
      "low": {
        "fhir_comments": [
          "   Healthy creatinine level ranges from 64umol/L to 104umol/L   "
        ],
        "value": 64
      },
      "high": {
        "value": 104
      },
      "meaning": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/referencerange-meaning",
            "code": "normal",
            "display": "Normal Range"
          }
        ]
      }
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.