R6 Ballot (2nd Draft)

Publish-box (todo)

Example CapabilityStatement/phr (XML)

FHIR Infrastructure Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

PHR Example (id = "phr")

<?xml version="1.0" encoding="UTF-8"?>

<CapabilityStatement xmlns="http://hl7.org/fhir">
  <id value="phr"/> 
  <text> 
    <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml">
     
      
      <p> Prototype Capability Statement for September 2013 Connectathon</p> 
     
      
      <p> The server offers read and search support on the following resource types:</p> 
     
      
      <ul> 
      
        
        <li> Patient</li> 
      
        
        <li> DocumentReference</li> 
      
        
        <li> Condition</li> 
      
        
        <li> DiagnosticReport</li> 
    
      
      </ul> 
    
    
    </div> 
  </text> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="fhir"/> 
  </extension> 
  <name value="PHRTemplate"/> 
  <title value="PHR Template"/> 
  <status value="draft"/> 
  <date value="2013-06-18"/> 
  <publisher value="HL7 International / FHIR Infrastructure"/> 
  <contact> 
    <telecom> 
      <system value="url"/> 
      <value value="http://www.hl7.org/Special/committees/fiwg"/> 
    </telecom> 
  </contact> 
  <description value="Prototype Capability Statement for September 2013 Connectathon"/> 
  <kind value="capability"/> 
  <software> 
    <name value="ACME PHR Server"/> 
  </software> 
  <fhirVersion value="6.0.0"/> 
  <format value="json"/> 
  <format value="xml"/> 
  <rest> 
    <mode value="server"/> 
    <documentation value="Protoype server Capability Statement for September 2013 Connectathon"/> 
    <security> 
      <service> 
        <text value="OAuth"/> 
      </service> 
      <description value="We recommend that PHR servers use standard OAuth using a          standard 3rd
       party provider. We are not testing the ability to provide an          OAuth authentication/au
      thorization service itself, and nor is providing          any security required
       for the connectathon at all"/> 
    </security> 
    <resource> 
      <type value="Patient"/> 
      <interaction> 
        <code value="read"/> 
      </interaction> 
      <interaction> 
        <code value="search-type"/> 
        <documentation value="When a client searches patients with no search criteria, they get a list of all
         patients they have access too. Servers may elect to offer additional search parameters,
         but this is not required"/> 
      </interaction> 
    </resource> 
    <resource> 
      <type value="DocumentReference"/> 
      <interaction> 
        <code value="read"/> 
      </interaction> 
      <interaction> 
        <code value="search-type"/> 
      </interaction> 
      <searchParam> 
        <name value="_id"/> 
        <type value="token"/> 
        <documentation value="_id parameter always supported. For the connectathon, servers may elect which search
         parameters are supported"/> 
      </searchParam> 
    </resource> 
    <resource> 
      <type value="Condition"/> 
      <interaction> 
        <code value="read"/> 
      </interaction> 
      <interaction> 
        <code value="search-type"/> 
      </interaction> 
      <searchParam> 
        <name value="_id"/> 
        <type value="token"/> 
        <documentation value="Standard _id parameter"/> 
      </searchParam> 
    </resource> 
    <resource> 
      <type value="DiagnosticReport"/> 
      <interaction> 
        <code value="read"/> 
      </interaction> 
      <interaction> 
        <code value="search-type"/> 
      </interaction> 
      <searchParam> 
        <name value="_id"/> 
        <type value="token"/> 
        <documentation value="Standard _id parameter"/> 
      </searchParam> 
      <searchParam> 
        <name value="service"/> 
        <type value="token"/> 
        <documentation value="which diagnostic discipline/department created the report"/> 
      </searchParam> 
    </resource> 
  </rest> 
</CapabilityStatement> 