R6 Ballot (2nd Draft)

Publish-box (todo)

Example CapabilityStatement/example (JSON)

FHIR Infrastructure Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

Raw JSON (canonical form + also see JSON Format Specification)

General Capability Example

{
  "resourceType" : "CapabilityStatement",
  "id" : "example",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n\t\t\t\n      <p>The EHR Server supports the following transactions for the resource Person: read, vread, \n        update, history, search(name,gender), create and updates.</p>\n\t\t\t\n      <p>The EHR System supports the following message: admin-notify::Person.</p>\n\t\t\t\n      <p>The EHR Application has a \n        \n        <a href=\"http://fhir.hl7.org/base/Profilebc054d23-75e1-4dc6-aca5-838b6b1ac81d/_history/b5fdd9fc-b021-4ea1-911a-721a60663796\">general document profile</a>.\n      \n      </p>\n\t\t\n    </div>"
  },
  "extension" : [{
    "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
    "valueCode" : "fhir"
  }],
  "url" : "urn:uuid:68d043b5-9ecf-4559-a57a-396e0d452311",
  "version" : "20130510",
  "name" : "ACMEEHR",
  "title" : "ACME EHR capability statement",
  "status" : "draft",
  "experimental" : true,
  "date" : "2012-01-04",
  "publisher" : "HL7 International / FHIR Infrastructure",
  "contact" : [{
    "telecom" : [{
      "system" : "url",
      "value" : "http://www.hl7.org/Special/committees/fiwg"
    }]
  }],
  "description" : "This is the FHIR capability statement for the main EHR at ACME for the private interface - it does not describe the public interface",
  "useContext" : [{
    "code" : {
      "system" : "http://terminology.hl7.org/CodeSystem/usage-context-type",
      "code" : "focus"
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/variant-state",
        "code" : "positive"
      }]
    }
  }],
  "jurisdiction" : [{
    "coding" : [{
      "system" : "urn:iso:std:iso:3166",
      "code" : "US",
      "display" : "United States of America"
    }]
  }],
  "purpose" : "Main EHR capability statement, published for contracting and operational support",
  "copyright" : "Copyright © Acme Healthcare and GoodCorp EHR Systems",
  "kind" : "instance",
  "instantiates" : ["http://ihe.org/fhir/CapabilityStatement/pixm-client"],
  "software" : {
    "name" : "EHR",
    "version" : "0.00.020.2134",
    "releaseDate" : "2012-01-04"
  },
  "implementation" : {
    "description" : "main EHR at ACME",
    "url" : "http://10.2.3.4/fhir"
  },
  "fhirVersion" : "6.0.0",
  "format" : ["xml",
  "json"],
  "patchFormat" : ["application/xml-patch+xml",
  "application/json-patch+json"],
  "acceptLanguage" : ["en",
  "es"],
  "implementationGuide" : ["http://example.org/fhir/us/lab"],
  "rest" : [{
    "mode" : "server",
    "documentation" : "Main FHIR endpoint for acem health",
    "security" : {
      "cors" : true,
      "service" : [{
        "coding" : [{
          "system" : "http://hl7.org/fhir/restful-security-service",
          "code" : "SMART-on-FHIR"
        }]
      }],
      "description" : "See Smart on FHIR documentation"
    },
    "resource" : [{
      "type" : "Patient",
      "profile" : "http://registry.fhir.org/r5/StructureDefinition/7896271d-57f6-4231-89dc-dcc91eab2416",
      "supportedProfile" : ["http://registry.fhir.org/r5/StructureDefinition/00ab9e7a-06c7-4f77-9234-4154ca1e3347"],
      "documentation" : "This server does not let the clients create identities.",
      "interaction" : [{
        "code" : "read"
      },
      {
        "code" : "vread",
        "documentation" : "Only supported for patient records since 12-Dec 2012"
      },
      {
        "code" : "update"
      },
      {
        "code" : "history-instance"
      },
      {
        "code" : "create"
      },
      {
        "code" : "history-type"
      }],
      "versioning" : "versioned-update",
      "readHistory" : true,
      "updateCreate" : false,
      "conditionalCreate" : true,
      "conditionalRead" : "full-support",
      "conditionalUpdate" : false,
      "conditionalPatch" : false,
      "conditionalDelete" : "not-supported",
      "searchInclude" : ["Patient:organization"],
      "searchRevInclude" : ["Person:patient"],
      "searchParam" : [{
        "name" : "identifier",
        "definition" : "http://hl7.org/fhir/SearchParameter/Patient-identifier",
        "type" : "token",
        "documentation" : "Only supports search by institution MRN"
      },
      {
        "name" : "general-practitioner",
        "definition" : "http://hl7.org/fhir/SearchParameter/Patient-general-practitioner",
        "type" : "reference"
      }]
    }],
    "interaction" : [{
      "code" : "transaction"
    },
    {
      "code" : "history-system"
    }],
    "compartment" : ["http://hl7.org/fhir/CompartmentDefinition/patient"]
  }],
  "messaging" : [{
    "endpoint" : [{
      "protocol" : {
        "system" : "http://hl7.org/fhir/message-transport",
        "code" : "mllp"
      },
      "address" : "mllp:10.1.1.10:9234"
    }],
    "reliableCache" : 30,
    "documentation" : "ADT A08 equivalent for external system notifications",
    "supportedMessage" : [{
      "mode" : "receiver",
      "definition" : "http://hl7.org/fhir/MessageDefinition/example"
    }]
  }],
  "document" : [{
    "mode" : "consumer",
    "documentation" : "Basic rules for all documents in the EHR system",
    "profile" : "http://fhir.hl7.org/base/Profilebc054d23-75e1-4dc6-aca5-838b6b1ac81d/_history/b5fdd9fc-b021-4ea1-911a-721a60663796"
  }]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.