This is Snapshot #3 for FHIR R5, released to support Connectathon 32. For a full list of available versions, see the Directory of published versions.
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
Example definition of serum or plasma specimen.
{ "resourceType" : "SpecimenDefinition", "id" : "2364", "text" : { "status" : "generated", "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: SpecimenDefinition</b><a name=\"2364\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource SpecimenDefinition "2364" </p></div><p><b>status</b>: active</p><p><b>typeCollected</b>: Venous blood specimen <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#122555007)</span></p><p><b>patientPreparation</b>: 12 hour fasting <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span>, At rest <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#263678003)</span></p><p><b>timeAspect</b>: preferrably morning time</p><blockquote><p><b>typeTested</b></p><p><b>type</b>: Serum specimen <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#119364003)</span></p><p><b>preference</b>: preferred</p><h3>Containers</h3><table class=\"grid\"><tr><td>-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td>plastic <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#61088005)</span></td><td>Evacuated blood collection tube, thrombin/clot activator/gel separator <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#702281005)</span></td><td>yellow cap <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (unknown#yellow)</span></td><td>2 ml<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mL = 'mL')</span></td></tr></table><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Ambient temperature <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><p><b>temperatureRange</b>: 15-25 °C</p><h3>MaxDurations</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>60</td><td>minute</td><td><a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>min</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Refrigerated temperature <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><p><b>temperatureRange</b>: 2-8 °C</p><h3>MaxDurations</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>8</td><td>hour</td><td><a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table></blockquote></blockquote><blockquote><p><b>typeTested</b></p><p><b>type</b>: Plasma specimen <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#119361006)</span></p><p><b>preference</b>: alternate</p><h3>Containers</h3><table class=\"grid\"><tr><td>-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td>glass <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#32039001)</span></td><td>Evacuated blood collection tube, thrombin/clot activator/gel separator <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#702281005)</span></td><td>green cap <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (unknown#green)</span></td><td>2 ml<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mL = 'mL')</span></td></tr></table><p><b>rejectionCriterion</b>: insufficient specimen volume <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-rejection-criteria.html\">RejectionCriterion</a>#insufficient)</span>, hemolized specimen <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-rejection-criteria.html\">RejectionCriterion</a>#hemolized)</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Ambient temperature <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><p><b>temperatureRange</b>: 15-25 °C</p><h3>MaxDurations</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>60</td><td>minute</td><td><a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>min</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Refrigerated temperature <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><p><b>temperatureRange</b>: 2-8 °C</p><h3>MaxDurations</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>8</td><td>hour</td><td><a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table></blockquote></blockquote></div>" }, "status" : "active", "typeCollected" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "122555007", "display" : "Venous blood specimen" }] }, "patientPreparation" : [{ "text" : "12 hour fasting" }, { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "263678003", "display" : "At rest" }] }], "timeAspect" : "preferrably morning time", "typeTested" : [{ "type" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "119364003", "display" : "Serum specimen" }] }, "preference" : "preferred", "container" : { "material" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "61088005", "display" : "plastic" }] }, "type" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "702281005", "display" : "Evacuated blood collection tube, thrombin/clot activator/gel separator" }] }, "cap" : { "coding" : [{ "system" : "urn:iso:std:iso:6710:2017", "code" : "yellow", "display" : "yellow cap" }] }, "minimumVolumeQuantity" : { "value" : 2, "unit" : "ml", "system" : "http://unitsofmeasure.org", "code" : "mL" } }, "handling" : [{ "temperatureQualifier" : { "text" : "Ambient temperature" }, "temperatureRange" : { "low" : { "value" : 15, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" }, "high" : { "value" : 25, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" } }, "maxDuration" : { "value" : 60, "unit" : "minute", "system" : "http://unitsofmeasure.org", "code" : "min" } }, { "temperatureQualifier" : { "text" : "Refrigerated temperature" }, "temperatureRange" : { "low" : { "value" : 2, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" }, "high" : { "value" : 8, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" } }, "maxDuration" : { "value" : 8, "unit" : "hour", "system" : "http://unitsofmeasure.org", "code" : "h" } }] }, { "type" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "119361006", "display" : "Plasma specimen" }] }, "preference" : "alternate", "container" : { "material" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "32039001", "display" : "glass" }] }, "type" : { "coding" : [{ "system" : "http://snomed.info/sct", "code" : "702281005", "display" : "Evacuated blood collection tube, thrombin/clot activator/gel separator" }] }, "cap" : { "coding" : [{ "system" : "urn:iso:std:iso:6710:2017", "code" : "green", "display" : "green cap" }] }, "minimumVolumeQuantity" : { "value" : 2, "unit" : "ml", "system" : "http://unitsofmeasure.org", "code" : "mL" } }, "rejectionCriterion" : [{ "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/rejection-criteria", "code" : "insufficient", "display" : "insufficient specimen volume" }] }, { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/rejection-criteria", "code" : "hemolized", "display" : "hemolized specimen" }] }], "handling" : [{ "temperatureQualifier" : { "text" : "Ambient temperature" }, "temperatureRange" : { "low" : { "value" : 15, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" }, "high" : { "value" : 25, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" } }, "maxDuration" : { "value" : 60, "unit" : "minute", "system" : "http://unitsofmeasure.org", "code" : "min" } }, { "temperatureQualifier" : { "text" : "Refrigerated temperature" }, "temperatureRange" : { "low" : { "value" : 2, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" }, "high" : { "value" : 8, "unit" : "°C", "system" : "http://unitsofmeasure.org", "code" : "Cel" } }, "maxDuration" : { "value" : 8, "unit" : "hour", "system" : "http://unitsofmeasure.org", "code" : "h" } }] }] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 Ballot hl7.fhir.core#5.0.0-snapshot3 generated on Wed, Dec 14, 2022 07:17+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4B |
Compare to R5 Draft |
|
Propose a change