Snapshot 3: Connectathon 32 Base

This is Snapshot #3 for FHIR R5, released to support Connectathon 32. For a full list of available versions, see the Directory of published versions.

Example Observation/blood-pressure-cancel (Narrative)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile Observation.


Generated Narrative: Observation

Resource Observation "blood-pressure-cancel"

Profile: Vital Signs Profile

identifier: id: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281

status: cancelled

category: Vital Signs (Observation Category Codes#vital-signs)

code: Blood pressure systolic & diastolic (LOINC#85354-9 "Blood pressure panel with all children optional")

subject: Patient/example "Peter CHALMERS"

effective: 2012-09-17

performer: Practitioner/example "Adam CAREFUL"

interpretation: Below low normal (ObservationInterpretation#L "low")

note: In this example, the blood pressure measurements are not available due to cancellation of the order. Data absent reason is present for each component

bodySite: Right arm (SNOMED CT#368209003)

component

code: Systolic blood pressure (LOINC#8480-6; SNOMED CT#271649006; clinical-codes#bp-s "Systolic Blood pressure")

dataAbsentReason: Not Asked (DataAbsentReason#not-asked)

component

code: Diastolic blood pressure (LOINC#8462-4)

dataAbsentReason: Not Asked (DataAbsentReason#not-asked)


 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.