Snapshot 3: Connectathon 32 Base

This is Snapshot #3 for FHIR R5, released to support Connectathon 32. For a full list of available versions, see the Directory of published versions.

Example Device/example-udi3 (XML)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

example-udi3 (id = "example-udi3")

<?xml version="1.0" encoding="UTF-8"?>

<Device xmlns="http://hl7.org/fhir">
  <id value="example-udi3"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="example-udi3"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device &quot;example-udi3&quot; </p> </div> <p> <b> identifier</b> : Serial Number: XYZ456789012345678</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td> *</td> <td> 007444534255003288</td> <td> <a href="http://hl7.org/fhir/NamingSystem/hibcc">http://hl7.org/fhir/NamingSystem/hibcc</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> +H123PARTNO1234567890120/$$420020216LOT123456789012345/SXYZ456789012345678/16D20130202C</td> <td> manual</td> </tr> </table> <p> <b> status</b> : inactive</p> <p> <b> manufacturer</b> : GlobalMed, Inc</p> <p> <b> manufactureDate</b> : 2013-02-02</p> <p> <b> expirationDate</b> : 2020-02-02</p> <p> <b> lotNumber</b> : LOT123456789012345</p> <h3> DeviceNames</h3> <table class="grid"><tr> <td> -</td> <td> <b> Name</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> Ultra Implantable</td> <td> user-friendly-name</td> </tr> </table> <h3> Associations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Status</b> </td> <td> <b> HumanSubject</b> </td> </tr> <tr> <td> *</td> <td> attached <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (device-association-status#attached)</span> </td> <td> <a href="patient-example.html">Patient/example</a>  &quot;Peter CHALMERS&quot;</td> </tr> </table> </div> </text> <identifier> 
        <!--   The serial number which is a component of the production identifier (PI), a conditional,
     variable portion of a UDI. The identifier.type code should be set to “SNO”(Serial
     Number) and the system left empty.    -->
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/> 
        <code value="SNO"/> 
      </coding> 
    </type> 
    <value value="XYZ456789012345678"/> 
        <!--     this is the serial number    -->
  </identifier> 
  <udiCarrier> 
      <deviceIdentifier value="007444534255003288"/> 
    <issuer value="http://hl7.org/fhir/NamingSystem/hibcc"/> 
    <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> 
    <carrierHRF value="+H123PARTNO1234567890120/$$420020216LOT123456789012345/SXYZ456789012345678/16D20130202C"/> 
    <entryType value="manual"/> 
  </udiCarrier> 
  <status value="inactive"/> 
  <manufacturer value="GlobalMed, Inc"/> 
  <manufactureDate value="2013-02-02"/> 
  <expirationDate value="2020-02-02"/> 
  <lotNumber value="LOT123456789012345"/> 
  <deviceName> 
      <name value="Ultra Implantable"/> 
      <type value="user-friendly-name"/> 
    </deviceName> 
  <association> 
    <status>  
       <coding> 
       <system value="http://terminology.hl7.org/CodeSystem/device-association-status"/> 
           <code value="attached"/> 
     </coding> 
    </status> 
      <humanSubject> 
    <reference value="Patient/example"/> 
    </humanSubject> 
  </association> 
</Device> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.