Snapshot 3: Connectathon 32 Base

This is Snapshot #3 for FHIR R5, released to support Connectathon 32. For a full list of available versions, see the Directory of published versions.

Example Device/example-udi1 (XML)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

example-udi1 (id = "example-udi1")

<?xml version="1.0" encoding="UTF-8"?>

<Device xmlns="http://hl7.org/fhir">

  <id value="example-udi1"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="example-udi1"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device &quot;example-udi1&quot; </p> </div> <p> <b> identifier</b> : 1234-5678-90AB-CDEF, Serial Number: 10987654d321</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierAIDC</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td> *</td> <td> 00844588003288</td> <td> <a href="http://hl7.org/fhir/NamingSystem/gs1">http://hl7.org/fhir/NamingSystem/gs1</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH</td> <td> {01}00844588003288{17}141120{10}7654321D{21}10987654d321</td> <td> barcode</td> </tr> </table> <p> <b> status</b> : active</p> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> expirationDate</b> : 2014-11-20</p> <p> <b> lotNumber</b> : 7654321D</p> <h3> DeviceNames</h3> <table class="grid"><tr> <td> -</td> <td> <b> Name</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> PM/Octane 2014</td> <td> user-friendly-name</td> </tr> </table> <p> <b> type</b> : Coated femoral stem prosthesis, modular <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #468063009)</span> </p> <h3> Associations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Status</b> </td> <td> <b> HumanSubject</b> </td> </tr> <tr> <td> *</td> <td> attached <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (device-association-status#attached)</span> </td> <td> <a href="patient-example.html">Patient/example</a>  &quot;Peter CHALMERS&quot;</td> </tr> </table> <p> <b> safety</b> : MR Unsafe <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (unknown#mr-unsafe)</span> </p> </div> </text> <identifier> 
     <type> 
      <coding> 
           <system value="http://acme.com/devices/pacemakers/octane/serial"/> 
    </coding> 
     </type> 
     <value value="1234-5678-90AB-CDEF"/> 
  </identifier> 
  <identifier> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/> 
        <code value="SNO"/> 
      </coding> 
    </type> 
    <value value="10987654d321"/> 
  </identifier> 
  <udiCarrier> 
    <deviceIdentifier value="00844588003288"/> 
    <issuer value="http://hl7.org/fhir/NamingSystem/gs1"/> 
    <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> 
    <carrierAIDC value="XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH"/> 
    <carrierHRF value="{01}00844588003288{17}141120{10}7654321D{21}10987654d321"/> 
    <entryType value="barcode"/> 
  </udiCarrier> 
  <status value="active"/> 
  <manufacturer value="Acme Devices, Inc"/> 
  <expirationDate value="2014-11-20"/> 
  <lotNumber value="7654321D"/> 
  <deviceName> 
      <name value="PM/Octane 2014"/> 
      <type value="user-friendly-name"/> 
    </deviceName> 
  <type> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="468063009"/> 
      <display value="Coated femoral stem prosthesis, modular"/> 
    </coding> 
    <text value="Coated femoral stem prosthesis, modular"/> 
        <!--    note: optional text value added here for a prettier generated narrative    -->
  </type> 
  <association> 
    <status>  
       <coding> 
       <system value="http://terminology.hl7.org/CodeSystem/device-association-status"/> 
           <code value="attached"/> 
     </coding> 
    </status> 
      <humanSubject> 
    <reference value="Patient/example"/> 
    </humanSubject> 
  </association> 
  <safety> 
    <coding> 
      <system value="urn:oid:2.16.840.1.113883.3.26.1.1"/> 
      <code value="mr-unsafe"/> 
      <display value="MR Unsafe"/> 
    </coding> 
    <text value="MR Unsafe"/> 
        <!--    note: optional text value added here for a prettier generated narrative    -->
  </safety> 
  
</Device> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.