Snapshot 3: Connectathon 32 Base

This is Snapshot #3 for FHIR R5, released to support Connectathon 32. For a full list of available versions, see the Directory of published versions.

Example AuditEvent/example (XML)

Security Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Patient, Practitioner

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

General AuditEvent Example (id = "example")

<?xml version="1.0" encoding="UTF-8"?>

<AuditEvent xmlns="http://hl7.org/fhir">
  <id value="example"/> 
  <text> 
    <status value="generated"/> 
    <div xmlns="http://www.w3.org/1999/xhtml">Application Start for under service login &quot;Grahame&quot; (id: Grahame's Test
       HL7Connect)</div> 
  </text> 
  <category> 
    <coding> 
      <system value="http://dicom.nema.org/resources/ontology/DCM"/> 
      <code value="110100"/> 
      <display value="Application Activity"/> 
    </coding> 
  </category> 
  <code> 
    <coding> 
      <system value="http://dicom.nema.org/resources/ontology/DCM"/> 
      <code value="110120"/> 
      <display value="Application Start"/> 
    </coding> 
  </code> 
  <action value="E"/> 
  <recorded value="2012-10-25T22:04:27+11:00"/> 
  <outcome> 
    <code> 
      <system value="http://terminology.hl7.org/CodeSystem/audit-event-outcome"/> 
      <code value="success"/> 
      <display value="Success"/> 
    </code> 
  </outcome> 
  <agent> 
    <role> 
      <text value="Service User (Logon)"/> 
    </role> 
    <who> 
      <identifier> 
        <value value="Grahame"/> 
      </identifier> 
    </who> 
    <requestor value="false"/> 

  </agent> 
  <agent> 
      <!--   Source active participant, the software making the . AlternativeUserId - Process
     ID   -->
    <extension url="http://hl7.org/fhir/StructureDefinition/auditevent-AlternativeUserID">
      <valueIdentifier> 
        <type> 
          <text value="process ID"/> 
        </type> 
        <value value="6580"/> 
      </valueIdentifier> 
    </extension> 
    <who> 
      <identifier> 
        <system value="urn:oid:2.16.840.1.113883.4.2"/> 
        <value value="2.16.840.1.113883.4.2"/> 
      </identifier> 
    </who> 
    <requestor value="false"/> 
    <networkString value="Workstation1.ehr.familyclinic.com"/> 

  </agent> 
  <source> 
    <observer> 
      <display value="Grahame's Laptop"/> 
    </observer> 
    <type> 
      <coding> 
        <system value="http://dicom.nema.org/resources/ontology/DCM"/> 
        <code value="110122"/> 
        <display value="Login"/> 
      </coding> 
    </type> 
  </source> 
  <entity> 
    <what> 
      <identifier> 
        <type> 
          <coding> 
            <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/> 
            <code value="SNO"/> 
          </coding> 
          <text value="Dell Serial Number"/> 
        </type> 
        <value value="ABCDEF"/> 
      </identifier> 
    </what> 

    <role> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/object-role"/> 
        <code value="4"/> 
        <display value="Domain Resource"/> 
      </coding> 
    </role> 
  </entity> 
</AuditEvent> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.