This is Snapshot #3 for FHIR R5, released to support Connectathon 32. For a full list of available versions, see the Directory of published versions.
Clinical Decision Support Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
Raw XML (canonical form + also see XML Format Specification)
Certainty Rating of all-cause mortality in meta-analysis of RCTs of heparin for moderately ill patients with COVID-19 (id = "example-certainty-rating")
<?xml version="1.0" encoding="UTF-8"?> <ArtifactAssessment xmlns="http://hl7.org/fhir"> <id value="example-certainty-rating"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: ArtifactAssessment</b> <a name="example-certainty-rating"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource ArtifactAssessment "example-certainty-rating" </p> </div> <p> <b> identifier</b> : FEvIR Object Identifier: 27756</p> <p> <b> date</b> : 2021-11-02T14:48:59.89Z</p> <p> <b> copyright</b> : https://creativecommons.org/licenses/by-nc-sa/4.0/</p> <p> <b> artifact</b> : <a href="broken-link.html">Evidence/18812: Critically appraised summary of all-cause mortality in meta-analysis of RCTs of heparin for moderately ill patients with COVID-19</a> </p> <blockquote> <p> <b> content</b> </p> <p> <b> informationType</b> : rating</p> <p> <b> summary</b> : serious concerns with risk of bias, inconsistency, and imprecision</p> <p> <b> type</b> : Overall certainty <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-type.html">EvidenceCertaintyType</a> #Overall)</span> </p> <p> <b> classifier</b> : Very low quality <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-rating.html">EvidenceCertaintyRating</a> #very-low)</span> </p> <p> <b> author</b> : <span> : Brian S. Alper</span> </p> <p> <b> freeToShare</b> : true</p> <h3> Components</h3> <table class="grid"><tr> <td> -</td> <td> <b> InformationType</b> </td> <td> <b> Summary</b> </td> <td> <b> Type</b> </td> <td> <b> Classifier</b> </td> <td> <b> Author</b> </td> </tr> <tr> <td> *</td> <td> rating</td> <td> risk of bias in both included trials</td> <td> Risk of bias <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-type.html">EvidenceCertaintyType</a> #RiskOfBias)</span> </td> <td> serious concern <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-rating.html">EvidenceCertaintyRating</a> #serious-concern)</span> </td> <td> <span> : Brian S. Alper</span> </td> </tr> <tr> <td> *</td> <td> rating</td> <td> high degree of heterogeneity (I-squared 80.7%) with confidence intervals of 2 trial effect estimates barely overlapping</td> <td> Inconsistency <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-type.html">EvidenceCertaintyType</a> #Inconsistency)</span> </td> <td> serious concern <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-rating.html">EvidenceCertaintyRating</a> #serious-concern)</span> </td> <td> <span> : Brian S. Alper</span> </td> </tr> <tr> <td> *</td> <td> rating</td> <td> </td> <td> Indirectness <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-type.html">EvidenceCertaintyType</a> #Indirectness)</span> </td> <td> no serious concern <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-rating.html">EvidenceCertaintyRating</a> #no-concern)</span> </td> <td> <span> : Brian S. Alper</span> </td> </tr> <tr> <td> *</td> <td> rating</td> <td> 95% confidence interval includes both large effects and no effects</td> <td> Imprecision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-type.html">EvidenceCertaintyType</a> #Imprecision)</span> </td> <td> serious concern <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-rating.html">EvidenceCertaintyRating</a> #serious-concern)</span> </td> <td> <span> : Brian S. Alper</span> </td> </tr> <tr> <td> *</td> <td> rating</td> <td> </td> <td> Publication bias <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-type.html">EvidenceCertaintyType</a> #PublicationBias)</span> </td> <td> no serious concern <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-certainty-rating.html">EvidenceCertaintyRating</a> #no-concern)</span> </td> <td> <span> : Brian S. Alper</span> </td> </tr> </table> </blockquote> </div> </text> <identifier> <type> <text value="FEvIR Object Identifier"/> </type> <system value="https://fevir.net"/> <value value="27756"/> <assigner> <display value="Computable Publishing LLC"/> </assigner> </identifier> <date value="2021-11-02T14:48:59.890Z"/> <copyright value="https://creativecommons.org/licenses/by-nc-sa/4.0/"/> <artifactReference> <reference value="Evidence/18812"/> <type value="Evidence"/> <display value="Critically appraised summary of all-cause mortality in meta-analysis of RCTs of heparin for moderately ill patients with COVID-19"/> </artifactReference> <content> <informationType value="rating"/> <summary value="serious concerns with risk of bias, inconsistency, and imprecision"/> <type> <coding> <system value="http://hl7.org/fhir/certainty-type"/> <code value="Overall"/> <display value="Overall certainty"/> </coding> </type> <classifier> <coding> <system value="http://terminology.hl7.org/CodeSystem/certainty-rating"/> <code value="very-low"/> <display value="Very low quality"/> </coding> </classifier> <author> <display value="Brian S. Alper"/> </author> <freeToShare value="true"/> <component> <informationType value="rating"/> <summary value="risk of bias in both included trials"/> <type> <coding> <system value="http://hl7.org/fhir/certainty-type"/> <code value="RiskOfBias"/> <display value="Risk of bias"/> </coding> </type> <classifier> <coding> <system value="http://terminology.hl7.org/CodeSystem/certainty-rating"/> <code value="serious-concern"/> <display value="serious concern"/> </coding> </classifier> <author> <display value="Brian S. Alper"/> </author> </component> <component> <informationType value="rating"/> <summary value="high degree of heterogeneity (I-squared 80.7%) with confidence intervals of 2 trial effect estimates barely overlapping"/> <type> <coding> <system value="http://hl7.org/fhir/certainty-type"/> <code value="Inconsistency"/> <display value="Inconsistency"/> </coding> </type> <classifier> <coding> <system value="http://terminology.hl7.org/CodeSystem/certainty-rating"/> <code value="serious-concern"/> <display value="serious concern"/> </coding> </classifier> <author> <display value="Brian S. Alper"/> </author> </component> <component> <informationType value="rating"/> <type> <coding> <system value="http://hl7.org/fhir/certainty-type"/> <code value="Indirectness"/> <display value="Indirectness"/> </coding> </type> <classifier> <coding> <system value="http://terminology.hl7.org/CodeSystem/certainty-rating"/> <code value="no-concern"/> <display value="no serious concern"/> </coding> </classifier> <author> <display value="Brian S. Alper"/> </author> </component> <component> <informationType value="rating"/> <summary value="95% confidence interval includes both large effects and no effects"/> <type> <coding> <system value="http://hl7.org/fhir/certainty-type"/> <code value="Imprecision"/> <display value="Imprecision"/> </coding> </type> <classifier> <coding> <system value="http://terminology.hl7.org/CodeSystem/certainty-rating"/> <code value="serious-concern"/> <display value="serious concern"/> </coding> </classifier> <author> <display value="Brian S. Alper"/> </author> </component> <component> <informationType value="rating"/> <type> <coding> <system value="http://hl7.org/fhir/certainty-type"/> <code value="PublicationBias"/> <display value="Publication bias"/> </coding> </type> <classifier> <coding> <system value="http://terminology.hl7.org/CodeSystem/certainty-rating"/> <code value="no-concern"/> <display value="no serious concern"/> </coding> </classifier> <author> <display value="Brian S. Alper"/> </author> </component> </content> </ArtifactAssessment>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 Ballot hl7.fhir.core#5.0.0-snapshot3 generated on Wed, Dec 14, 2022 07:16+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4B |
Compare to R5 Draft |
|
Propose a change