This page is part of the FHIR Specification (v5.0.0-snapshot1: Release 5 Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3
| Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw Turtle (+ also see Turtle/RDF Format Specification)
Blood Pressure Measurement cancelled
@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/rdf#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir/Observation/blood-pressure-cancel> a fhir:Observation;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "blood-pressure-cancel"];
fhir:Resource.meta [
fhir:Meta.profile [
fhir:value "http://hl7.org/fhir/StructureDefinition/vitalsigns";
fhir:index 0;
fhir:link <http://hl7.org/fhir/StructureDefinition/vitalsigns>
]
];
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ];
fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div><p>Resource "blood-pressure-cancel" </p><p>Profile: <a>Vital Signs Profile</a></p></div><p><b>identifier</b>: id: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281</p><p><b>status</b>: cancelled</p><p><b>category</b>: Vital Signs <span> (<a>Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Blood pressure systolic & diastolic <span> (<a>LOINC</a>#85354-9 "Blood pressure panel with all children optional")</span></p><p><b>subject</b>: <a>Patient/example</a> "Peter CHALMERS"</p><p><b>effective</b>: 2012-09-17</p><p><b>performer</b>: <a>Practitioner/example</a> "Adam CAREFUL"</p><p><b>interpretation</b>: Below low normal <span> (<a>ObservationInterpretation</a>#L "low")</span></p><p><b>note</b>: In this example, the blood pressure measurements are not available due to cancellation of the order. Data absent reason is present for each component</p><p><b>bodySite</b>: Right arm <span> (<a>SNOMED CT</a>#368209003)</span></p><blockquote><p><b>component</b></p><p><b>code</b>: Systolic blood pressure <span> (<a>LOINC</a>#8480-6; <a>SNOMED CT</a>#271649006; clinical-codes#bp-s "Systolic Blood pressure")</span></p><p><b>dataAbsentReason</b>: Not Asked <span> (<a>DataAbsentReason</a>#not-asked)</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: Diastolic blood pressure <span> (<a>LOINC</a>#8462-4)</span></p><p><b>dataAbsentReason</b>: Not Asked <span> (<a>DataAbsentReason</a>#not-asked)</span></p></blockquote></div>"
];
fhir:Observation.identifier [
fhir:index 0;
fhir:Identifier.system [ fhir:value "urn:ietf:rfc:3986" ];
fhir:Identifier.value [ fhir:value "urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281" ]
];
fhir:Observation.status [ fhir:value "cancelled"];
fhir:Observation.category [
fhir:index 0;
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/observation-category" ];
fhir:Coding.code [ fhir:value "vital-signs" ];
fhir:Coding.display [ fhir:value "Vital Signs" ]
]
];
fhir:Observation.code [
fhir:CodeableConcept.coding [
fhir:index 0;
a loinc:85354-9;
fhir:Coding.system [ fhir:value "http://loinc.org" ];
fhir:Coding.code [ fhir:value "85354-9" ];
fhir:Coding.display [ fhir:value "Blood pressure panel with all children optional" ]
];
fhir:CodeableConcept.text [ fhir:value "Blood pressure systolic & diastolic" ]
];
fhir:Observation.subject [
fhir:link <http://hl7.org/fhir/Patient/example>;
fhir:Reference.reference [ fhir:value "Patient/example" ]
];
fhir:Observation.effectiveDateTime [ fhir:value "2012-09-17"^^xsd:date];
fhir:Observation.performer [
fhir:index 0;
fhir:link <http://hl7.org/fhir/Practitioner/example>;
fhir:Reference.reference [ fhir:value "Practitioner/example" ]
];
fhir:Observation.interpretation [
fhir:index 0;
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" ];
fhir:Coding.code [ fhir:value "L" ];
fhir:Coding.display [ fhir:value "low" ]
];
fhir:CodeableConcept.text [ fhir:value "Below low normal" ]
];
fhir:Observation.note [
fhir:index 0;
fhir:Annotation.text [ fhir:value "In this example, the blood pressure measurements are not available due to cancellation of the order. Data absent reason is present for each component" ]
];
fhir:Observation.bodySite [
fhir:CodeableConcept.coding [
fhir:index 0;
a sct:368209003;
fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
fhir:Coding.code [ fhir:value "368209003" ];
fhir:Coding.display [ fhir:value "Right arm" ]
]
];
fhir:Observation.component [
fhir:index 0;
fhir:Observation.component.code [
fhir:CodeableConcept.coding [
fhir:index 0;
a loinc:8480-6;
fhir:Coding.system [ fhir:value "http://loinc.org" ];
fhir:Coding.code [ fhir:value "8480-6" ];
fhir:Coding.display [ fhir:value "Systolic blood pressure" ]
], [
fhir:index 1;
a sct:271649006;
fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
fhir:Coding.code [ fhir:value "271649006" ];
fhir:Coding.display [ fhir:value "Systolic blood pressure" ]
], [
fhir:index 2;
fhir:Coding.system [ fhir:value "http://acme.org/devices/clinical-codes" ];
fhir:Coding.code [ fhir:value "bp-s" ];
fhir:Coding.display [ fhir:value "Systolic Blood pressure" ]
]
];
fhir:Observation.component.dataAbsentReason [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/data-absent-reason" ];
fhir:Coding.code [ fhir:value "not-asked" ];
fhir:Coding.display [ fhir:value "Not Asked" ]
]
]
], [
fhir:index 1;
fhir:Observation.component.code [
fhir:CodeableConcept.coding [
fhir:index 0;
a loinc:8462-4;
fhir:Coding.system [ fhir:value "http://loinc.org" ];
fhir:Coding.code [ fhir:value "8462-4" ];
fhir:Coding.display [ fhir:value "Diastolic blood pressure" ]
]
];
fhir:Observation.component.dataAbsentReason [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/data-absent-reason" ];
fhir:Coding.code [ fhir:value "not-asked" ];
fhir:Coding.display [ fhir:value "Not Asked" ]
]
]
] .
<http://hl7.org/fhir/Patient/example> a fhir:Patient .
<http://hl7.org/fhir/Practitioner/example> a fhir:Practitioner .
# - ontology header ------------------------------------------------------------
<http://hl7.org/fhir/Observation/blood-pressure-cancel.ttl> a owl:Ontology;
owl:imports fhir:fhir.ttl;
owl:versionIRI <http://build.fhir.org/Observation/blood-pressure-cancel.ttl> .
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.