R5 Final QA

This page is part of the FHIR Specification (v5.0.0-draft-final: Final QA Preview for R5 - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Example Procedure/example-implant (Turtle)

Patient Care Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Encounter, Patient, Practitioner, RelatedPerson

Raw Turtle (+ also see Turtle/RDF Format Specification)

Example of a device manipulation

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

[a fhir:Procedure ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "example-implant"] ; # 
  fhir:text [
     fhir:status [ fhir:v "generated" ] ;
     fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Procedure</b><a name=\"example-implant\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Procedure &quot;example-implant&quot; </p></div><p><b>status</b>: completed</p><p><b>code</b>: Implant Pacemaker <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#25267002 &quot;Insertion of intracardiac pacemaker (procedure)&quot;)</span></p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> &quot;Peter CHALMERS&quot;</p><p><b>occurrence</b>: 2015-04-05</p><h3>Performers</h3><table class=\"grid\"><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a href=\"practitioner-example.html\">Practitioner/example: Dr Cecil Surgeon</a> &quot;Adam CAREFUL&quot;</td></tr></table><h3>Reasons</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td></tr><tr><td>*</td><td>Bradycardia <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></td></tr></table><p><b>followUp</b>: ROS 5 days  - 2013-04-10 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><p><b>note</b>: Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p><h3>FocalDevices</h3><table class=\"grid\"><tr><td>-</td><td><b>Action</b></td><td><b>Manipulated</b></td></tr><tr><td>*</td><td>Implanted <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"codesystem-device-action.html\">Procedure Device Action Codes</a>#implanted)</span></td><td><a name=\"example-pacemaker\"> </a><blockquote><p/><p><a name=\"example-pacemaker\"> </a></p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>lotNumber</b>: 1234-5678</p><p><b>type</b>: Cardiac pacemaker implant <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#14106009)</span></p></blockquote></td></tr></table></div>"
  ] ; # 
  fhir:contained ( [
     a fhir:Device ;
     fhir:id [ fhir:v "example-pacemaker" ] ;
     fhir:manufacturer [ fhir:v "Acme Devices, Inc" ] ;
     fhir:lotNumber [ fhir:v "1234-5678" ] ;
     fhir:type ( [
       fhir:coding ( [
         a sct:14106009 ;
         fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "14106009" ] ;
         fhir:display [ fhir:v "Cardiac pacemaker implant" ]
       ] )
     ] )
  ] ) ; #    <association> 
#      <status> 
#        <coding>
#          <system value="http://hl7.org/fhir/device-association-status"/>
#          <code value="implanted"/>
#        </coding>
#      </status>
#      <humanSubject> 
#        <reference value="Patient/example"/> 
#      </humanSubject> 
#		</association>    
  fhir:status [ fhir:v "completed"] ; # 
  fhir:code [
     fhir:coding ( [
       a sct:25267002 ;
       fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "25267002" ] ;
       fhir:display [ fhir:v "Insertion of intracardiac pacemaker (procedure)" ]
     ] ) ;
     fhir:text [ fhir:v "Implant Pacemaker" ]
  ] ; # 
  fhir:subject [
     fhir:reference [ fhir:v "Patient/example" ]
  ] ; # 
  fhir:occurrence [ fhir:v "2015-04-05"^^xsd:date] ; # 
  fhir:performer ( [
     fhir:actor [
       fhir:reference [ fhir:v "Practitioner/example" ] ;
       fhir:display [ fhir:v "Dr Cecil Surgeon" ]
     ]
  ] ) ; # 
  fhir:reason ( [
     fhir:concept [
       fhir:text [ fhir:v "Bradycardia" ]
     ]
  ] ) ; # 
  fhir:followUp ( [
     fhir:text [ fhir:v "ROS 5 days  - 2013-04-10" ]
  ] ) ; # 
  fhir:note ( [
     fhir:text [ fhir:v "Routine Appendectomy. Appendix was inflamed and in retro-caecal position" ]
  ] ) ; # 
  fhir:focalDevice ( [
     fhir:action [
       fhir:coding ( [
         fhir:system [ fhir:v "http://hl7.org/fhir/device-action"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "implanted" ]
       ] )
     ] ;
     fhir:manipulated [
       fhir:reference [ fhir:v "#example-pacemaker" ]
     ]
  ] )] . # 

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.