This page is part of the FHIR Specification (v5.0.0-draft-final: Final QA Preview for R5 - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
Public Health and Emergency Response Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Patient, Practitioner |
Raw XML (canonical form + also see XML Format Specification)
Example of Immunization with a Reaction (id = "reaction")
<?xml version="1.0" encoding="UTF-8"?> <Immunization xmlns="http://hl7.org/fhir"> <id value="reaction"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Immunization</b> <a name="reaction"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Immunization "reaction" </p> </div> <p> <b> identifier</b> : id: urn:oid:1.3.6.1.4.1.21367.2005.3.7.1234</p> <p> <b> status</b> : completed</p> <p> <b> vaccineCode</b> : Rabies - IM Diploid cell culture <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/4.0.0/CodeSystem-v2-0292.html">PH_VaccinesAdministeredCVX_CDC_NIP</a> #175)</span> </p> <h3> Manufacturers</h3> <table class="grid"><tr> <td> -</td> <td> <b> Reference</b> </td> </tr> <tr> <td> *</td> <td> <a href="organization-example.html">Organization/hl7</a> "Health Level Seven International"</td> </tr> </table> <p> <b> lotNumber</b> : PPL909K</p> <p> <b> expirationDate</b> : 2023-01-21</p> <p> <b> patient</b> : <a href="patient-example.html">Patient/example</a> "Peter CHALMERS"</p> <p> <b> encounter</b> : <a href="encounter-example.html">Encounter/example</a> </p> <p> <b> occurrence</b> : 2021-09-12</p> <p> <b> primarySource</b> : true</p> <p> <b> location</b> : <a href="location-example.html">Location/1</a> "South Wing, second floor"</p> <p> <b> site</b> : left arm <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/4.0.0/CodeSystem-v3-ActSite.html">ActSite</a> #LA)</span> </p> <p> <b> route</b> : Injection, intramuscular <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/4.0.0/CodeSystem-v3-RouteOfAdministration.html">RouteOfAdministration</a> #IM)</span> </p> <p> <b> doseQuantity</b> : 5 mg<span style="background: LightGoldenRodYellow"> (Details: UCUM code mg = 'mg')</span> </p> <blockquote> <p> <b> performer</b> </p> <p> <b> function</b> : Ordering Provider <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/4.0.0/CodeSystem-v2-0443.html">providerRole</a> #OP)</span> </p> <p> <b> actor</b> : <a href="practitioner-example.html">Practitioner/example</a> "Adam CAREFUL"</p> </blockquote> <blockquote> <p> <b> performer</b> </p> <p> <b> function</b> : Administering Provider <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/4.0.0/CodeSystem-v2-0443.html">providerRole</a> #AP)</span> </p> <p> <b> actor</b> : <a href="practitioner-example.html">Practitioner/example</a> "Adam CAREFUL"</p> </blockquote> <p> <b> note</b> : Notes on adminstration of vaccine</p> <h3> Reasons</h3> <table class="grid"><tr> <td> -</td> <td> <b> Reference</b> </td> </tr> <tr> <td> *</td> <td> <a href="observation-example.html">Observation/example</a> </td> </tr> </table> <p> <b> isSubpotent</b> : false</p> <blockquote> <p> <b> reaction</b> </p> <p> <b> date</b> : 2021-09-12</p> <h3> Manifestations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Reference</b> </td> </tr> <tr> <td> *</td> <td> <a href="broken-link.html">Observation/example2</a> </td> </tr> </table> <p> <b> reported</b> : false</p> </blockquote> </div> </text> <identifier> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:1.3.6.1.4.1.21367.2005.3.7.1234"/> </identifier> <status value="completed"/> <vaccineCode> <coding> <system value="http://hl7.org/fhir/sid/cvx"/> <code value="175"/> </coding> <text value="Rabies - IM Diploid cell culture"/> </vaccineCode> <manufacturer> <reference> <reference value="Organization/hl7"/> </reference> </manufacturer> <lotNumber value="PPL909K"/> <expirationDate value="2023-01-21"/> <patient> <reference value="Patient/example"/> </patient> <encounter> <reference value="Encounter/example"/> </encounter> <occurrenceDateTime value="2021-09-12"/> <primarySource value="true"/> <location> <reference value="Location/1"/> </location> <site> <coding> <system value="http://terminology.hl7.org/CodeSystem/v3-ActSite"/> <code value="LA"/> <display value="left arm"/> </coding> </site> <route> <coding> <system value="http://terminology.hl7.org/CodeSystem/v3-RouteOfAdministration"/> <code value="IM"/> <display value="Injection, intramuscular"/> </coding> </route> <doseQuantity> <value value="5"/> <system value="http://unitsofmeasure.org"/> <code value="mg"/> </doseQuantity> <performer> <function> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0443"/> <code value="OP"/> </coding> </function> <actor> <reference value="Practitioner/example"/> </actor> </performer> <performer> <function> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0443"/> <code value="AP"/> </coding> </function> <actor> <reference value="Practitioner/example"/> </actor> </performer> <note> <text value="Notes on adminstration of vaccine"/> </note> <reason> <reference> <reference value="Observation/example"/> </reference> </reason> <isSubpotent value="false"/> <reaction> <date value="2021-09-12"/> <manifestation> <reference> <reference value="Observation/example2"/> </reference> </manifestation> <reported value="false"/> </reaction> </Immunization>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0-draft-final generated on Wed, Mar 1, 2023 23:06+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4B |
Compare to R5 Draft |
|
Propose a change