This page is part of the FHIR Specification (v5.0.0-draft-final: Final QA Preview for R5 - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Example DeviceMetric/example (XML)
Raw XML (canonical form + also see XML Format Specification)
Jump past Narrative
General DeviceMetric example (id = "example")
<?xml version="1.0" encoding="UTF-8"?>
<DeviceMetric xmlns="http://hl7.org/fhir">
<id value="example"/>
<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: DeviceMetric</b> <a name="example"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource DeviceMetric "example" </p> </div> <p> <b> identifier</b> : id: 345675</p> <p> <b> type</b> : MDC_PULS_OXIM_SAT_O2 <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/4.0.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #150456)</span> </p> <p> <b> unit</b> : MDC_DIM_PERCENT <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/4.0.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #262688)</span> </p> <p> <b> device</b> : <a href="broken-link.html">Device/dev1</a> </p> <p> <b> operationalStatus</b> : on</p> <p> <b> color</b> : blue</p> <p> <b> category</b> : measurement</p> <p> <b> measurementFrequency</b> : 1 Hertz<span style="background: LightGoldenRodYellow"> (Details: UCUM code Hz = 'Hz')</span> </p> <h3> Calibrations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Type</b> </td> <td> <b> State</b> </td> <td> <b> Time</b> </td> </tr> <tr> <td> *</td> <td> two-point</td> <td> calibrated</td> <td> 29 Dec 2016, 1:03:04 am</td> </tr> </table> </div> </text> <identifier>
<system value="http://goodcare.org/devicemetric/id"/>
<value value="345675"/>
</identifier>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="150456"/>
<display value="MDC_PULS_OXIM_SAT_O2"/>
</coding>
</type>
<unit>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="262688"/>
<display value="MDC_DIM_PERCENT"/>
</coding>
</unit>
<device>
<reference value="Device/dev1"/>
</device>
<operationalStatus value="on"/>
<color value="blue"/>
<category value="measurement"/>
<measurementFrequency>
<value value="1"/>
<unit value="Hertz"/>
<system value="http://unitsofmeasure.org"/>
<code value="Hz"/>
</measurementFrequency>
<calibration>
<type value="two-point"/>
<state value="calibrated"/>
<time value="2016-12-28T09:03:04-05:00"/>
</calibration>
</DeviceMetric>
Usage note: every effort has been made to ensure that the
examples are correct and useful, but they are not a normative part
of the specification.