R5 Final QA

This page is part of the FHIR Specification (v5.0.0-draft-final: Final QA Preview for R5 - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3

Example Device/example-udi4 (XML)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Not linked to any defined compartments

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

example-udi4 (id = "example-udi4")

<?xml version="1.0" encoding="UTF-8"?>

<Device xmlns="http://hl7.org/fhir">
  <id value="example-udi4"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="example-udi4"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device &quot;example-udi4&quot; </p> </div> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierHRF</b> </td> </tr> <tr> <td> *</td> <td> A4599XQZ990T0474</td> <td> <a href="http://hl7.org/fhir/NamingSystem/iccbba-blood">http://hl7.org/fhir/NamingSystem/iccbba-blood</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> =)1TE123456A&amp;)RZ12345678</td> </tr> </table> <p> <b> status</b> : inactive</p> <p> <b> manufacturer</b> : GlobalMed, Inc</p> <p> <b> lotNumber</b> : RZ12345678</p> </div> </text> <udiCarrier> 
  <deviceIdentifier value="A4599XQZ990T0474"/> 
    <issuer value="http://hl7.org/fhir/NamingSystem/iccbba-blood"/> 
    <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> 
    <carrierHRF value="=)1TE123456A&amp;)RZ12345678"/> 
  </udiCarrier> 
  <status value="inactive"/> 
  <manufacturer value="GlobalMed, Inc"/> 
  <lotNumber value="RZ12345678"/> 
      <!--    <association>
    <status> 
       <coding>
       <system value="http://terminology.hl7.org/CodeSystem/device-association-status"
   />
           <code value="attached"/>
     </coding>
    </status>
      <humanSubject>
    <reference value="Patient/example"/>
    </humanSubject>
  </association>    -->
</Device> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.