R5 Final QA

This page is part of the FHIR Specification (v5.0.0-draft-final: Final QA Preview for R5 - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Example Device/device-example-specimen-container-example-sst-vacutainer (XML)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Not linked to any defined compartments

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

device-example-specimen-container-example-sst-vacutainer (id = "device-example-specimen-container-example-sst-vacutainer")

<?xml version="1.0" encoding="UTF-8"?>

<Device xmlns="http://hl7.org/fhir">    <!--   text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
      <p>example</p>
    </div>
  </text   --><id value="device-example-specimen-container-example-sst-vacutainer"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="device-example-specimen-container-example-sst-vacutainer"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device &quot;device-example-specimen-container-example-sst-vacutainer&quot;
           </p> </div> <p> <b> identifier</b> : id: 345679</p> <p> <b> displayName</b> : SST Tube</p> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : Container Type <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (codes#container-type)</span> </p> <p> <b> value</b> : SST Tube <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (types#SST)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : Amount <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (codes#amount)</span> </p> <p> <b> value</b> : 4.5 mL <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (capacities#4.5mL)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : Additive <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (codes#additive)</span> </p> <p> <b> value</b> : gel <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (additive#gel)</span> </p> </blockquote> </div> </text> <identifier> 
    <system value="http://acme.com/containers/id"/> 
    <value value="345679"/> 
  </identifier> 
  <displayName value="SST Tube"/> 
  <property> 
    <type> 
     <coding> 
        <system value="http://acme.com/containers/codes"/> 
        <code value="container-type"/> 
        <display value="Container Type"/> 
    </coding> 
  </type> 
  <valueCodeableConcept> 
      <coding> 
        <system value="http://acme.com/containers/types"/> 
        <code value="SST"/> 
        <display value="SST Tube"/> 
      </coding> 
  </valueCodeableConcept> 
  </property> 
  <property> 
    <type> 
    <coding> 
        <system value="http://acme.com/containers/codes"/> 
        <code value="amount"/> 
        <display value="Amount"/> 
    </coding> 
  </type> 
  <valueCodeableConcept> 
    <coding> 
        <system value="http://acme.com/containers/capacities"/> 
        <code value="4.5mL"/> 
        <display value="4.5 mL"/> 
      </coding> 
  </valueCodeableConcept> 
  </property> 
  <property> 
    <type> 
      <coding> 
        <system value="http://acme.com/containers/codes"/> 
        <code value="additive"/> 
        <display value="Additive"/> 
    </coding> 
    </type> 
    <valueCodeableConcept> 
    <coding> 
        <system value="http://acme.com/containers/additive"/> 
        <code value="gel"/> 
        <display value="gel"/> 
      </coding> 
    </valueCodeableConcept> 
  </property> 
</Device> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.