This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile SpecimenDefinition.
Generated Narrative: SpecimenDefinition
Resource SpecimenDefinition "2364"
status: active
typeCollected: Venous blood specimen (SNOMED CT#122555007)
patientPreparation: 12 hour fasting (), At rest (SNOMED CT#263678003)
timeAspect: preferrably morning time
typeTested
type: Serum specimen (SNOMED CT#119364003)
preference: preferred
Containers
- Material Type Cap MinimumVolume[x] * plastic (SNOMED CT#61088005) Evacuated blood collection tube, thrombin/clot activator/gel separator (SNOMED CT#702281005) yellow cap (unknown#yellow) 2 ml (Details: UCUM code mL = 'mL') handling
temperatureQualifier: Ambient temperature ()
temperatureRange: 15-25 °C
MaxDurations
- Value Unit System Code * 60 minute Unified Code for Units of Measure (UCUM) min handling
temperatureQualifier: Refrigerated temperature ()
temperatureRange: 2-8 °C
MaxDurations
- Value Unit System Code * 8 hour Unified Code for Units of Measure (UCUM) h
typeTested
type: Plasma specimen (SNOMED CT#119361006)
preference: alternate
Containers
- Material Type Cap MinimumVolume[x] * glass (SNOMED CT#32039001) Evacuated blood collection tube, thrombin/clot activator/gel separator (SNOMED CT#702281005) green cap (unknown#green) 2 ml (Details: UCUM code mL = 'mL') rejectionCriterion: insufficient specimen volume (RejectionCriterion#insufficient), hemolized specimen (RejectionCriterion#hemolized)
handling
temperatureQualifier: Ambient temperature ()
temperatureRange: 15-25 °C
MaxDurations
- Value Unit System Code * 60 minute Unified Code for Units of Measure (UCUM) min handling
temperatureQualifier: Refrigerated temperature ()
temperatureRange: 2-8 °C
MaxDurations
- Value Unit System Code * 8 hour Unified Code for Units of Measure (UCUM) h
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.