This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Patient Care Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
Example of a device manipulation (id = "example-implant")
<?xml version="1.0" encoding="UTF-8"?> <Procedure xmlns="http://hl7.org/fhir"> <id value="example-implant"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Procedure</b> <a name="example-implant"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Procedure "example-implant" </p> </div> <p> <b> status</b> : completed</p> <p> <b> code</b> : Implant Pacemaker <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #25267002 "Insertion of intracardiac pacemaker (procedure)")</span> </p> <p> <b> subject</b> : <a href="patient-example.html">Patient/example</a> "Peter CHALMERS"</p> <p> <b> occurrence</b> : 2015-04-05</p> <h3> Performers</h3> <table class="grid"><tr> <td> -</td> <td> <b> Actor</b> </td> </tr> <tr> <td> *</td> <td> <a href="practitioner-example.html">Practitioner/example: Dr Cecil Surgeon</a> "Adam CAREFUL"</td> </tr> </table> <h3> Reasons</h3> <table class="grid"><tr> <td> -</td> <td> <b> Concept</b> </td> </tr> <tr> <td> *</td> <td> Bradycardia <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span> </td> </tr> </table> <p> <b> followUp</b> : ROS 5 days - 2013-04-10 <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span> </p> <p> <b> note</b> : Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p> <h3> FocalDevices</h3> <table class="grid"><tr> <td> -</td> <td> <b> Action</b> </td> <td> <b> Manipulated</b> </td> </tr> <tr> <td> *</td> <td> Implanted <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-device-action.html">Procedure Device Action Codes</a> #implanted)</span> </td> <td> <a name="example-pacemaker"> </a> <blockquote> <p/> <p> <a name="example-pacemaker"> </a> </p> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> lotNumber</b> : 1234-5678</p> <p> <b> type</b> : Cardiac pacemaker implant <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #14106009)</span> </p> <h3> Associations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Status</b> </td> <td> <b> HumanSubject</b> </td> </tr> <tr> <td> *</td> <td> Implanted <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-device-association-status.html">FHIRDeviceaAsociationStatus</a> #implanted)</span> </td> <td> <a href="patient-example.html">Patient/example</a> "Peter CHALMERS"</td> </tr> </table> </blockquote> </td> </tr> </table> </div> </text> <contained> <Device> <id value="example-pacemaker"/> <manufacturer value="Acme Devices, Inc"/> <lotNumber value="1234-5678"/> <type> <coding> <system value="http://snomed.info/sct"/> <code value="14106009"/> <display value="Cardiac pacemaker implant"/> </coding> </type> <association> <status> <coding> <system value="http://hl7.org/fhir/device-association-status"/> <code value="implanted"/> </coding> </status> <humanSubject> <reference value="Patient/example"/> </humanSubject> </association> </Device> </contained> <status value="completed"/> <code> <coding> <system value="http://snomed.info/sct"/> <code value="25267002"/> <display value="Insertion of intracardiac pacemaker (procedure)"/> </coding> <text value="Implant Pacemaker"/> </code> <subject> <reference value="Patient/example"/> </subject> <occurrenceDateTime value="2015-04-05"/> <performer> <actor> <reference value="Practitioner/example"/> <display value="Dr Cecil Surgeon"/> </actor> </performer> <reason> <concept> <text value="Bradycardia"/> </concept> </reason> <followUp> <text value="ROS 5 days - 2013-04-10"/> </followUp> <note> <text value="Routine Appendectomy. Appendix was inflamed and in retro-caecal position"/> </note> <focalDevice> <action> <coding> <system value="http://hl7.org/fhir/device-action"/> <code value="implanted"/> </coding> </action> <manipulated> <reference value="#example-pacemaker"/> </manipulated> </focalDevice> </Procedure>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.